Installation Instructions

This symbol indicates prohibition. The specific prohibited action is provided in and/or
around the figure.
Warning
Caution
Warning
Caution
INSTALLATION INSTRUCTIONS
No. 59-2032-3
FEATURES
Indicates a potentially hazardous situation which, if not avoided, will result
in minor or moderate injury, or may result in serious injury or death.
Additionally there may be significant property damage.
Indicates a potentially hazardous situation which, if not avoided, may result
in minor or moderate injury or in property damage.
Read this instruction manual carefully prior to installation.
After reading, store this manual carefully in an easily accessible place for reference.
This manual uses the following warning indications for correct use of the product, harm to you
or other people and damage to your assets, which are described below. Be sure to understand
the description before reading the rest of this manual.
This symbol requires an action or gives an instruction.
This symbol indicates recommendation.
INTRODUCTION
1
1-1
BEFORE YOUR OPERATION
30m/100ft.
SL-100 TNR
60m/200ft.
SL-200 TNR
DETECTION RANGE
MODEL
Do not use the product for purposes other than the detection of moving objects such as people and vehicles.
Do not use the product to activate a shutter, etc., which may cause an accident.
Do not touch the unit base or power terminals of the product with a wet hand (do not touch
when the product is wet with rain, etc.). It may cause electric shock.
Never attempt to disassemble or repair the product. It may cause fire or damage to the devices.
Do not use batteries that have different levels of power remaining (i.e., new and used batteries).
Not observing the above may result in an explosion, leakage of electrolyte, emission of toxic
gases or other outcomes that may be harmful to people and property.
[Handling of Batteries] Do not recharge, short circuit, crush, disassemble, exceed heat above
100°C (212°F), incinerate, or expose contents to water. Do not solder directly to the cell.
Do not pour water over the product with a bucket, hose, etc. The water may enter, which may
cause damage to the devices.
Clean and check the product periodically for safe use. If any problem is found, do not attempt to
use the product as it is and have the product repaired by a professional engineer or electrician.
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
Smart Line series
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
Smart Line series
1-2
PRECAUTIONS
PREPARATIONS
- 1 -
2
1-3
PARTS IDENTIFICATION
Do not install the
unit on an unstable
surface.
Do not install the pole
in a location where
sufficient stability can
not be ensured.
Do not install the unit in
trees, leaves, or other
objects that may swing
in the wind and block
the beam.
Do not install the
receiver in a
location where it is
exposed to direct
sunlight.
Do not allow the infrared
beam from a another detector
to reach the receiver.
Install the unit at a height
where an object can be
detected without fail.
The pole size should be
43 to 48 mm dia.
(1.69 to 1.89 inch dia.).
Install the unit at least 1
m (3.3 ft.) away from the
wall or fence that may be
running parallel to the
beam.
Accessories>>
Velcro tape: 1 set
U-brackets: 2Pole brackets: 2
4×20 self tapping for wall mounting
(with rubber washer): 4
M4×16 screws for pole mounting
(with rubber washer): 4
Cables: 3
Receiver
Transmitter
(another
detector)
Receiver
(another
detector)
Transmitter
1 m (3.3 ft.)
Battery operated detector
- D size lithium battery or CR123A lithium battery (OPTION CRH-5)
Simplified optical adjustment
- Sniper View Finder with ×2 magnification
Avoids having to install a wireless transmitter in the photoelectric transmitter.
- IR signal transmission technology transfers the low battery signal to the receiver
Possible to connect the power and alarm cables to both the receiver and the transmitter or either of them
- OPTION PCU-5
Long battery life
Battery saving function
Intermittent output function
Slim body design
Easy to see vivid interior color
for optical alignment
IP65 waterproof structure
Tamper function
Indicator LED for an easy alignment
Various options (Refer to page 4.)
(BCU-5, CRH-5, PCU-5)
Detector power source Battery type Wireless transmitter power source
D-size
4 pcs.From detector battery
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
4 pcs.
2 pcs.
2 pcs.
16 pcs.
Wireless
Either Transmitter or
Receiver
Both Transmitter and
Receiver
Wired
16 pcs.
8 pcs.
8 pcs.
2 sets
2 sets
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
2 sets
2 sets
No
Need
No
Need
D size
CR123A
D size
CR123A
No
Need
No
Need
No
Need
CR123A CRH-5 BCU-5 PCU-5
BATTERY OPTION*
For Wireless transmitter
Main unit cover
Battery cover
Main unit Back box
Viewfinder
Optical
alignment dial
Optical lens
Battery cover
lock screw
Main unit cover
lock screw
Main unit mounting
bracket
Dip SW
(Receiver only)
* Refer to “9 OPTIONS” on page 4.
Unit: mm (inch)
141 (5.6)
35 (1.4)
47 (1.9)
Wireless transmitter size
.
- 4 -
1
2
3
Be sure to conduct a walk test at the following three points:
A. In front of the transmitter
B. In front of the receiver
C. At the mid point between the transmitter and receiver
The detector is installed properly when Alarm/Level indicator LED turns
ON in the tests at all the three points.
5-2
OPERATION CHECK
After installation is complete, be sure to check the operation.
Make sure that the Alarm/Level indicator LED is OFF.
If it is illuminated even when the beams are not blocked, make optical
alignment again.
Check that the Power/Low battery indicator LEDs on both transmitter and
receiver are ON.
If the Power/Low battery indicator LED is blinking, the battery power is low.
Replace with new batteries.
Conduct a walk test to check that Alarm/Level indicator LED on the
receiver turns ON as the walker interrupts the beams.
Specifications and design are subject to change without prior notice.
* The value is based on the condition that it is used within the ambient temperature range of 20 to 25°C.
** Using batteries other than those recommended may shorten the battery life.
TROUBLESHOOTING
6
SPECIFICATIONS
8
OPTIONS
9
These units are designed to detect an intruder and activate an alarm control panel. Being
only a part of a complete system, we cannot accept responsibility for any damages or
other consequences resulting from an intrusion.
These products conform to the EMC Directive 2004/108/EC.
NOTE
Model
SL-100TNR SL-200TNR
Maximum detection range 30 m/100 ft.
Maximum arrival distance 265 m/800 ft.
Total: Approx. 500 μA
Transmitter: Approx. 200 μA
Receiver: Approx. 300 μA
Total: Approx. 600 μA
Transmitter: Approx. 300 μA
Receiver: Approx. 300 μA
Total: Approx. 600 μA
Transmitter: Approx. 200 μA
Receiver: Approx. 400 μA
Total: Approx. 700 μA
Transmitter: Approx. 300 μA
Receiver: Approx. 400 μA
60 m/200 ft.
530 m/1740 ft.
Detection method Twin infrared beam interruption detection
SB-D02HP
by VITZROCELL
3.9 VDC
3.0 VDC
Transmitter
Receiver
Approx. 6 years
Approx. 5 years
Approx. 5 years
Approx. 5 years
Transmitter
Receiver
Approx. 1.5 years
Approx. 1 year
Approx. 1 year
Approx. 1 year
CRH-5 (CR123A
by Panasonic)
Interruption time
Variable between 50/100/250/500 ms (4 steps)
Power source
3.9 VDC D size lithium batteries Each Transmitter and Receiver: 2 units
(SB-D02HP manufactured by VITZROCELL)
3.0 VDC CR123A lithium batteries Each Transmitter and Receiver: 8 units
(OPTION CRH-5: 2unit)
Current draw
(stand by /at 25°C)
Battery
life
Alarm output
Form C-Solid State Switch: 3.9 VDC, 0.01 A
Alarm period 2 s (±1)
Low battery output
N.C. (Solid State Switch): 3.9 VDC, 0.01 A
Cover tamper output
(Receiver)
N.C. (Solid State Switch): 3.9 VDC, 0.01 A
Opens when the battery cover removed.
Alarm/ Level indicator
ON: Beam not received
(Receiver)
Blinking: Beam not received sufficiently
OFF: Beam received
Power/ Low battery indicator
(Transmitter and Receiver)
ON: Power ON
Blinking: Voltage reduction
OFF: Power OFF
Operating temperature -20°C to +60°C (-4°F to 140°F)
Operating humidity 95 % (max.)
Alignment angle ±90° Horizontal, ±5° Vertical
Dimension
H × W × D mm (inch): 295 (11.6) × 69 (2.7) × 117 (4.6)
Weight
1200 g (Total weight of Transmitter + Receiver, excluding accessories)
International protection IP65
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Power/Low battery indicator LEDs are
not illuminated. (transmitter/receiver)
Reversed battery polarity. Check the battery polarity.
Alarm is not output.
5HÀHFWLRQIURPWKHÀRRURUZDOO
Beam has not been blocked. Block all two beams.
Batteries are running out too quickly. Set the cover properly.
Optical alignment not optimized.
Improper output Problem with wiring. Install the correct wiring.
Batteries are inactive condition.
Align beams away from the floor or wall.
Problem with tamper output.
DIMENSIONS
7
Output
Indicator
LED
*
**
BCU-5 Battery Common use Unit (1 unit/set)
Unit: mm (inch)
Share power source and low battery signals between the main unit and the wireless
transmitter.
CRH-5 CR123A Battery Holder (2 units/set)
Battery holder when using CR123A as a power source
PCU-5 Power Convertor Unit (1 unit/set, battery is sold separately.)
Voltage convertor unit used to enable wired operation of the detector
55 (2.2)
26 (1.0)
16 (0.6)
See “4-2 OPTICAL ALIGNMENT”
on page 3 and make realignment.
Open and close the battery cover
20 times with two seconds intervals.
After this, open the battery plate
and then close it.
When the beam is blocked, the
“ALARM” indicator LED is illuminated
but the alarm is not activated.
Alarm is activated even if the
light is not blocked.
Even if new batteries are used, Low
battery indicator LED is ON.
Signal line short-circuited Check the wiring.
Interruption time is too short.
See “4-1 BEAM INTERRUPTION
ADJUSTMENT” on page 3, set an
appropriate interruption time.
Surface of Transmitter/Receiv-
er cover soiled.
Clean the cover (wipe the cover with
a soft cloth dampened with water or
diluted neutral detergent).
Optical alignment was not
performed properly.
See “4-2 OPTICAL ALIGNMENT” on
page 3 and make realignment.
Frost, snow or heavy rain
causes false alarm.
A
B
Transmitter
Receiver
C
Unit: mm (inch)
295 (11.6)
117 (4.6)
69 (2.7)
83.5 (3.3)
(WALL)
Unit: mm (inch)
34 (1.3)
34 (1.3)
56 (2.2)
Unit: mm (inch)
71 (2.8)
20 (0.8)
53 (2.1)
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
OPTEX INC. (U.S.)
www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY SAS (France)
www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex.com.pl
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX PINNACLE INDIA, PVT., LTD. (India)
www.optex.net/in/en/sec
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
www.optex.eu
Copyright (C) 2016 OPTEX CO., LTD.

Summary of content (2 pages)