No.59-3169-0 2208-18 UL No.59-3169-0 2208-18 INSTALLATION INSTRUCTIONS EN Flexible Range Indoor Detector FlipX series PROFESSIONAL MODELS Wide/Narrow area Flip lens FLX-P-ST ✓ ✓ - ✓ ✓ ✓(10.525GHz) FLX-P-DT-X8* ✓ ✓ ✓(10.587GHz) FLX-P-DT-X9* ✓ ✓ ✓(9.
Before installation - Manufacturer’ s statement Symbol Symbol Meaning Check mark indicates recommendation. Failure to follow the instructions provided with this indication Warning and improper handling may cause death or serious injury. Caution Warning Meaning Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage. Destroy modify Nix sign indicates prohibition.
- Parts identifications Base Sponge Option CW-G2 * Bracket for wall/ceiling mount Main unit Cover Joint screw x 3 Fixing screw x 2 PEU: Plug-in EOL Unit Lens *Not certified to SBSC. 1 Installation 1-1. Disassemble 1 Unlock the cover 2 Open the cover 3 Remove the main unit 180° Do not touch MW and PIR units.
1-2. Wall mount without bracket 1 How to break the knockouts Wire through the base Wiring knockouts For Wall/ Corner mount Surface wiring : Upper For Wall/ Corner mount : Lower Hidden wiring: A. Surface wiring B. Hidden wiring A-1. Upper 2 A-2. Lower Mount the base a. Wall mount Mounting holes b. Corner mount For Wall mount For Corner mount Select 2 of the 3 on each side. NOTE Mounting screws are not included. Φ 3 mm screws are recommended.
1-3. Wall mount with bracket 1 Wire and mount on the wall Wiring knockout guide Punch out 3 knockout guides to open the wiring hole to allow wire run. NOTE Mounting screws are not included. Φ 3 mm screws are recommended. Wiring knockout hole NOTE See page 4 for how to break the knockouts. 2 3 Join the base on the bracket Joint screw x3 Fix the base with the fixing screws (optional) Fixing screw x2 The bracket is basically jointed using 3 holes and 3 joint screws.
1-4. Ceiling mount with bracket How to change the bracket to the ceiling mounting [1] Loosen the fixing screw. [2] Rotate the body. [3] Tighten the fixing screw. WALL CEILING Rear side Rear side WALL 1 CEILING Wire and mount on the ceiling Wiring knockout guide Punch out 3 knockout guides to open the wiring hole to allow wire run. Wiring knockout hole NOTE Mounting screws are not included. NOTE Φ 3 mm screws are recommended. See page 4 for how to break the knockouts.
1-5. Assembe and connect 1 Attach the main unit to the base [1] Hook the top of the PCB on the protrusions on both sides. [2] Push the bottom of the PCB over the protruding claws. 2 Connect wires to the terminal + - SP LED ALARM TAMP N.C. N.C. (Normally Close) +12 V - Power Spare Remote LED * Alarm Tamper * State not evaluated by UL Power cable length The power cable should be limited to the following length.
2 Settings 2-1. Wide/Narrow setting Page Go to 2-2 on 9 to skip 2-1 when using the default “Wide” setting. 1 Set the Flip lens to “Wide” or “Narrow” WIDE NARROW Default NOTE Install the lens so that the letters on the cover and on the lens match your intention. How to remove the lens Get over the rib, then pull up the lens. Caution Be careful not to damage the light path of the LED. Also, be careful not to allow the light path to pinch the wiring when closing the cover.
How to install the lens Push the lens firmly at 3 points in numerical order. 3 2 1 2 Set the jumper pin to “Wide” or “Narrow” Caution LENS W N The jumper pin must be “Narrow” , when the lens is set to “Narrow” . 3 Wide/Narrow NOTE Default setting is “Wide” . When “Narrow” is selected, MW detection will be disabled. 2-2.
2-3. PEU settings EOL resistors Alarm Tamper Relay & Tamper inside the detector + - SP LED ALARM PEU socket TAMP Wiring to the control panel Grade 2 1 2 NOTE Align both triangle marks.
3 Checking 3-1. Walk test 1 Confirm that the LED pin is “ON” , then close the cover. 2 Walk in the detection area to check the detecting performance via LED indication. ON OFF LED 1 LED 3 4 Return the LED pin to “OFF” after the walk test, if necessary. Lock the cover ON OFF LED 1 LED 180° (optional) NOTE Conduct a walk test at least once a year.
Others - Specifications Model FLX-P-ST FLX-P-DT-X5/-X8/-X9 Detection method Passive infrared Passive infrared and Microwave Coverage Wide:15 m (50 ft.) 85°/ Narrow:24 m (80 ft.) 5° Installation ( No MW detection at “Narrow” setting ) Detection zones Wide: 78 zones/ Narrow: 18 zones Mounting height 2.0 to 3.0 m (6'7" to 9'8”) 2.0 ± 0.5 s Alarm period Approx. 60 s (LED blinks) Warm-up period Switchable ON/OFF Green: [1] Warm-up [2] Alarm LED indicator Electrical Power input 9.
- Dimensions with CW-G2 bracket 50.9 (2.00) 129.2 (5.09) 61.5 (2.42) 102.6 (4.04) 137.8 (5.43) 120.1 (4.73) Unit: mm (inch) - Detection area Wide - Top view - Narrow - Top view - 0 10 20 30 40 50 ft. 8 20 6 4 10 2 PIR 0 0 2 MW Short MW Long 0 10 20 30 40 50 60 70 2 0 2m 10 0 2 4 6 8 10 12 14 16 18 20 22 80 ft. 6 3 0 3 6 ft. 24 m 4 6 20 ft.
- Angle adjustment with bracket CW-G2 -7- 5゚ 20゚ 5゚ 20゚ 45゚ NOTE * If the detector cover does not reach the ceiling, it can be swung up to +5°.
- Compliance RE Directive 2014/53/EU ■ OPTEX declares that FLX-P-DT-X5, FLX-P-DT-X8, and FLX-P-DT-X9 comply with RE Directive 2014/53/EU. Doc documents can be found on our website; www.optex.net ■ Microwave emission Frequency and Power FLX-P-DT-X5: 10.525 GHz FLX-P-DT-X8: 10.587 GHz FLX-P-DT-X9: 9.425 GHz 15.78 mW e.i.r.p 8.93 mW e.i.r.p 14.50 mW e.i.r.p ■ The following list indicates the areas of intended use of the equipment and any known restrictions.