USER'S MANUAL PHL-7100 PHL-7200 Ruggedized Portable Data Terminal.
OPTICON User's manual PHL-7000 series Document:PHL-7100, PHL-7200 User's manual Distributed: Opticon Sensors Europe B.V., Hoofddorp CAUTION: This information is subject to change without prior notice. Copyright 2006, Opticon Sensors Europe B.V. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon Sensors Europe.
OPTICON User's manual PHL-7000 series Table of Contents Table of Contents ....................................................................... 1-3 Chapter 1. Introduction .............................................................. 1-1 1.1 About this Manual................................................................ 1-1 1.2 User and Product Safety ..................................................... 1-2 1.3 Battery Safety......................................................................
OPTICON User's manual PHL-7000 series 2.5.1 Setting Time and Date............................................... 2-48 2.5.2 Entering the Data ...................................................... 2-48 2.5.3 The Command Bar.................................................... 2-49 2.5.4 The Task Bar ............................................................. 2-49 2.5.5 The Soft Keypad........................................................ 2-50 2.5.6 Setting Up Wireless LAN RF ............................
OPTICON User's manual PHL-7000 series 3.3 Taskbar and Start Menu..................................................... 3-53 Chapter 4. Communication ........................................................ 4-1 4.1 Installing & Setting Up Microsoft ActiveSync ....................... 4-1 4.1.1 Installing Microsoft ActiveSync on the Host PC........... 4-1 4.1.2 Connecting PDT to Host PC........................................ 4-1 4.2 Using ActiveSync............................................................
OPTICON User's manual PHL-7000 series Chapter 1. Introduction Congratulations on purchasing the Opticon PHL-7000 series Portable Data Terminal (PDT), a Microsoft Windows®CE .Net rugged PDT. Its special combination of features makes it perfect for using in a wide range of applications. These features as: λ λ λ λ λ λ λ λ λ Intel® XScaleTM PXA255 400MHz 32 bits RISC processor Windows® CE .NET 4.2 Operating System 128 MB SDRAM & 64 MB FlashROM User accessible SD/CF slot 240 x 320, 3.
OPTICON User's manual PHL-7000 series 1.2 User and Product Safety • Do not stare into the laser or LED beam directly or shine it into eyes. • Never use strong pressure onto the screen or subject it to severe impact, as the LCD panel could become cracked and possibility cause personal injury. If the LCD panel is broken, never touch the liquid inside because the liquid irritates the skin.
OPTICON User's manual PHL-7000 series 1.3 Battery Safety Lithium-ion battery packs might get hot, explode, ignite and/or cause serious injury if exploded by abusive using. Please follow the safety warnings listed as below: • Do not throw the battery pack in fire. Do not expose the battery to high temperatures. • Do not connect the positive battery pack with negative battery pack to each other with any metal object (like wire). • Do not carry or store battery pack together with metal objects.
OPTICON User's manual PHL-7000 series 1.4 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
OPTICON User's manual PHL-7000 series 1.5 Recycling & disposal instructions. Do not throw this product in the home waste bin. For proper end-of-life treatment consult the Environmental care section of www.opticon.com 1.6 Regulatory information. For CE, FCC, RoHS and other Document of Conformities, consult the Regulatory section of www.opticon.
OPTICON User's manual PHL-7000 series 1.7 Product Labeling The PHL-7100 series PDT has several labels as showed in Figure 1-1 and 1-2. Figure 1-1 PHL-7100 Labeling (Front and side views) Label nr.
OPTICON User's manual PHL-7000 series Figure 1-2 PHL-7100 Labeling (Rear view) Label nr. Description 3 System and regulatory label 4 LED/Laser radiation warning label 5 Warranty label bar code reader 6 Serial number 7 Article number and model number 8 Windows CE .
OPTICON User's manual PHL-7000 series The PHL-7200 series PDT has several labels as showed in Figure 1-3 and 1-4. Figure 1-3 PHL-7200 Labeling (Front and side views) Label nr.
OPTICON User's manual PHL-7000 series Figure 1-4 PHL-7200 Labeling (Rear view) Label nr. Description 3 System and regulatory label 4 LED/Laser radiation warning label 5 Warranty label bar code reader 6 Serial number 7 Article number and model number 8 Windows CE .
OPTICON User's manual PHL-7000 series 1.8 System Specifications The PHL-7000 series detailed specifications as follows. Unless otherwise noted, all the specifications are subject to change without prior notification. PHL-7100, PHL-7200 Processor - 400MHz Intel PXA255 32 bits RISC CPU Memory - 64 MB Flash ROM - 128 MB SDRAM Display - 240 x 320 3.5” TFT 256K Color LCD with LED backlight Audio Radio Support Communication Ports Scan Engine Expansion Slot LED - One mono speaker - 2.
OPTICON User's manual PHL-7000 series PHL-7100, PHL-7200 PHL-7100 Power System - Standard Li-Ion battery pack, 3.7V, 3000mAh - Advanced smart battery - Built-in battery charger - 2.4V/15mAh rechargeable backup battery - Battery cover sensor switch - Power adapter: 100~240VAC, 50/60Hz input ; 5VDC, 2.
OPTICON User's manual PHL-7000 series PHL-7100, PHL-7200 Color Optional Peripherals and Accessories Software - Black - RS232 serial cable for PDT - USB host cable for PDT - High-capacity Li-Ion battery pack (3.7V, 4000mAh) - Compact Flash RFID card cover - IRU-7000 single slot cradle + battery charger - IRU-7004 4-slot battery charger - Power adapter for IRU-7000 and IRU-7004 100~240VAC, 50/60Hz input ; 5VDC, 6.5A output - Car adapter - Holster - Display Protect film - Microsoft Windows CE.NET 4.
OPTICON User's manual PHL-7000 series 1.9 Environment and durability. Operating Temperature 14oF ~ 122oF( -10oC ~ 50oC) Storage Temperature -4oF ~ 158oF (-20oC ~ 70oC) Humidity 5% ~ 80% (non-condensing) Drop 5ft (1.5m) Drop on concrete Water & Dust proof IP54 certified and IP64 compliant Vibration MIL STD 810F Table 1-6 Environmental and durability 1.10 Warranty and after service Should this PDT require service, please contact your local reseller.
OPTICON User's manual PHL-7000 series Chapter 2. Getting started 2.1 Check the package Open the package and check if no parts are missing or damaged: 2.1.1 PHL-7100 Figure 2-1 Package contents 1. PHL-7100 PDT 2. Stylus 3. USB client cable for PDT 4. Earphone/ microphone set 5. Standard AC adapter 5VDC/2.6A 6. AC power cord 7. Standard battery pack (3.7V, 3000 mAh) 8. CF support guide 9.
OPTICON User's manual PHL-7000 series 2.1.2 PHL-7200 Figure 2-2 Package contents 1. PHL-7200 PDT 2. Stylus 3. USB client cable for PDT 4. Earphone/ microphone set 5. Standard AC adapter 5VDC/2.6A 6. AC power cord 7. Standard battery pack (3.7V, 3000 mAh) 8. CF support guide 9.
OPTICON User's manual PHL-7000 series 2.2 General View of the PDT 2.2.1 PHL-7100 front view Figure 2-3 PHL-7100 front view 2.2.
OPTICON User's manual PHL-7000 series 1 2 Bar code reader LED “Red” color indicator “Green” color Bar code reader on Charge LED indicator “Red” color Charging battery “Green” color Successful reading Battery fully charged 3 LCM / touch panel User input on touch panel by stylus 4 Left scan key Right scan key Scan key Start scanning bar codes by pressing any of these three scan keys 5 Power key Put the PDT into suspend mode Awake the PDT from suspend mode 6 F1 ~ F4 key Application keys, hot
OPTICON User's manual PHL-7000 series 2.2.3 PHL-7200 front view Figure 2-5 PHL-7200 front view 2.2.
OPTICON User's manual PHL-7000 series 1 2 Bar code reader LED “Red” color indicator “Green” color Bar code reader on Charge LED indicator “Red” color Charging battery “Green” color Successful reading Battery fully charged 3 LCM / touch panel User input on touch panel by stylus 4 Left side scan key Start scanning bar codes by pressing any of Right side scan key these four scan keys Left upper scan key Right upper scan key 5 Power key Put the PDT into suspend mode Awake the PDT from suspend mod
OPTICON User's manual PHL-7000 series 2.3 Charging the Battery Pack Before using the PDT, install and charge the battery by executing the steps described in this paragraph. 2.3.1 Installing the battery pack 1. On the PDT attached with a hand-strap, detach the hand-strap. Figure 2-7 Release the Hand strap from PDT 2. Turn both battery cover latches downwards and lift the battery cover away from the PDT.
OPTICON User's manual PHL-7000 series 3. Insert the battery pack into the battery compartment with the label facing upwards, and ensuring the battery snaps into it's place. Figure 2-9 Insert the battery pack 4. Install the battery cover by inserting the top first, and then press the bottom in firmly. Turn both the battery cover latches upwards to secure the cover to the PDT.
OPTICON User's manual PHL-7000 series 2.3.2 Charging the battery pack with Power Adapter 1. Connect the power cord to the power adapter. 2. Plug in the connector of the power adapter to the PDT. 3. Connect the power cord to a power source. Figure 2-11 Charging with power adapter (PHL-7100 shown) 4. Charging time : to charge the battery pack for the first time, it needs approximately 6 hours. Subsequent charging time is approximately 4 hours.
OPTICON User's manual PHL-7000 series 2.3.3 Charging the battery pack with IRU-7000 CAUTION: IRU-7000 power adapter (5VDC/6.5A) is different from PDT power adapter (5VDC/2.6A). Please use the IRU-7000 Cradle power adapter only. a) Leave the battery pack inside the PDT : 1. Connect the power cord to the power adapter 2. Plug in the connector of the power adapter to the IRU-7000 3. Connect the power cord to a power source 4. Insert the PHL-7100 into the IRU-7000.
OPTICON User's manual PHL-7000 series b) Place the spare battery pack into the IRU-7000’s spare battery charging slot : 1. Connect the power cord to the power adapter 2. Plug in the connector of the power adapter to the IRU-7000 3. Connect the power cord to a power source 4. Insert the battery pack into the IRU-7000 spare battery slot • When charging the battery pack in the IRU-7000 spare battery slot, the IRU-7000 charging LED indicator turns on Red.
OPTICON User's manual PHL-7000 series 2.4 Handling the PDT 2.4.1 Starting the PDT Press the power key to turn ON/OFF the PDT. If the PDT does not power on, perform a cold boot, see chapter 2-7 Resetting. CAUTION: When a battery is fully inserted in PDT for the first time, the PDT powers on and boots automatically. When the PDT is powered on for the first time, it initializes its system. A splash screen (figure 2-10) appears for a short period of time followed by the WinCE.NET 4.2 window.
OPTICON User's manual PHL-7000 series 2.4.3 Calibration of the touch Screen On the initial boot-up of the PDT, the stylus calibration screen opens. Use the stylus to press and hold briefly on the center of each target as it moves around the screen. If necessary, adjust the backlight on the PDT to make the screen readable (see chapter 2.4.4 Adjusting the brightness).
OPTICON User's manual PHL-7000 series 2.4.5 To mute the sound To mute the sound, press the on of the sound. key first, and then press the key to turn off and 2.4.6 Using the stylus The stylus is located next to hand-strap on the rear of the PDT as illustrated in figure 2-3 PDT rear view. The stylus function is similar as the mouse on a PC. Use the stylus to: 1) Navigate the display, select menu item and open optional applications. 2) Tap the characters on soft keyboard panel.
OPTICON User's manual PHL-7000 series Key Fn + Main Function Main Function Alpha + Main Function User configurable Default : None Main bar code scan key Power On/Off Internet Explorer Microsoft WordPad Inbox File Explorer Right Backlight Increase Left Backlight Decrease Down Page Down Up Page Up ESC Audio Mute $ Backspace TAB Caps 1 @ : 2 A B C 3 ’ + D E F 4 Paste G H I 5 Del - J K L M N O P Q R 8 Copy & T U V 9 * W X Y € Change to letters Function c
OPTICON User's manual PHL-7000 series 0 Space Alpha + Main Function 〔 〕 . (Point) Start Menu , ; = % Key Fn + Main Function Main Function Enter Table 2-3 Keypad list Reset Key Definition Functionality Warm Reset Press “F1” and “F4” button simultaneously. Cold Reset Press “Power”, “F1” and “F4” button simultaneously. Table 2-3 Special reset key combinations Key Main Function Definition User configurable Configure its function by customer demand.
OPTICON User's manual PHL-7000 series Key Main Function Definition Down Move the cursor down one row or line The cursor will move continuously if button remains pressed. Up Move the cursor up one row or line The cursor will move continuously if button remains pressed. ESC This key performs a cancel action Backspace “Backspace” key, it moves the cursor back one space each time the key is pressed. It deletes the previous character each time it is pressed if you are typing text.
OPTICON User's manual PHL-7000 series Key Main Function Definition 5 Number key “5” 6 Number key “6” 7 Number key “7” 8 Number key “8” 9 Number key “9” 0 Number key “0” . Dot key Enter This key confirms data entry Table 2-4 Definition of main Function 2.4.7.1 Special Function by “Fn” + main Function The “Fn” key is used in combination with other keys to type special characters and perform system functions.
OPTICON User's manual PHL-7000 series Key Sequence Fn + Main Function Definition 2. You must press key, then key to cursor down press one page each time. 1. Move the cursor up one page. The cursor will move continuously if button remains pressed. Page Up 2. You must press press key, then key to cursor up one page each time. 1. Toggle the audio mute/on 2. You must press key, then Audio Mute press key to enable audio mute or turn on audio function each time. TAB (Tabulation) 1.
OPTICON User's manual PHL-7000 series Key Sequence Fn + Main Function Definition pressing + (Plus Sign) key. Enter a plus sign by pressing key, then pressing key 1. It is to do “Paste” function. 2. To do this function by pressing Paste key first, and then pressing key each time. 1. The “Delete” function delete the next character forward each time. 2. To do “Delete” function by pressing Del (Delete) key first, and then pressing key each time.
OPTICON User's manual PHL-7000 series Key Sequence Fn + Main Function Definition key first, and then pressing key. 1. The “Space” function is to input a space at the cursor. 2. To do this function by pressing Space key first, and then pressing key each time. 1. It displays the Start menu. 2. To do this function by pressing Start Menu key first, and then pressing key each time. Enter a backslash by pressing (Backslash) key first, and then pressing Table 2-5 Special Function key define 2-34 key.
OPTICON User's manual PHL-7000 series 2.4.7.2 Alpha keys by “Alpha” + main Function 1. The key enables you to toggle between the numeric and alpha modes. Numeric mode is when you type numbers with number keys. Alpha mode is when you type letters with the number keys. 2. When you press key, the “Alpha” icon appears at the task bar to indicate Alpha mode is enabled. It means Alpha mode is disabled if the “Alpha” icon is not present at Task bar.
OPTICON User's manual PHL-7000 series To enter g Press the Keys To enter G h H i I j J k K l L m M n N o O p P q Q r R s S t T u U v V w W x X y Y z Z 〔 〕 , ; = % Table 2-6 Alpha + Numeric keys define 2-36 Press the Keys
OPTICON User's manual PHL-7000 series 2.4.
OPTICON User's manual PHL-7000 series Key Main Function Fn + Main Function Down Page Down Up Page Up Esc Caps Tab Backspace A F5 B F6 C F7 D F8 E ( F ) G [ H ] I { J } K € L $ M # N % O ^ P ~ Q R , 、 S ! T ? U \ V = W X Y ; Z / 1 @ 2-38
OPTICON User's manual PHL-7000 series Key Main Function 2 Fn + Main Function 3 ’ + 4 Paste 5 6 Del - 7 Copy 8 9 & * 0 Start Menu . Space SHIFT Function change Enter Table 2-6 Keypad list Assembler Key Functionality Definition Warm Reset Press “F1” and “F4” button simultaneously. Cold Reset Press “Power”, “F1” and “F4” button simultaneously.
OPTICON User's manual PHL-7000 series Key Main Function Definition Microsoft WordPad Application key 2, User can define F2 function from setting. Inbox Application key 3, User can define F3 function from setting. File Explorer Application key 4, User can define F4 function from setting. Right Move the cursor one character to the right. The cursor will move continuously if button is pressed continuously. Move the cursor one character to the Left Down left.