Specifications

OPI-3301i
Specifications Manual
9
8. Technical Specifications
Code reading is performed by positioning the aiming light over the center of a code. The conditions for
technical specifications are as follows unless otherwise specified in each section.
<Conditions>
Temperature and humidity : Room temperature, room humidity
Ambient light : 100 ~ 200 lx
Angles : Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0°
Curvature : R =
Power supply voltage : 3.7 V
PCS (1D and 2D) : 0.9 or higher
Scanning Test : 1 read in 0.5 sec or less. Accept the performance with 70% or more
success rate for 10 readings.
Bar code test sample
(1D and 2D)
: Refer to Section 8.1. for details.
<Bar code test sample>
1D codes: OPTOELECTRONICS test samples
GS1 Databar, Stacked codes, 2D codes: Labels printed by a dedicated printer for bar code