7.2. Aiming Pattern
The aiming is used for the following purpose:
1. Light source to indicate the appropriate reading range
2. Light source for auto trigger operation
The aiming specifications are as follows:
An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=65±20 mm from the front edge of the scanner.
The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L=65
mm is 80%±10%.
Figure 2: Aiming Pattern and Imaging Range
7.3. Imaging Range
The range is ±5% from the following values.
L: Distance from the front edge of scanner
[mm]
40 60 80 100 120 140
H: Horizontal imaging range
[mm]
66 82 97 111 125 136
V: Vertical imaging range
[mm]
42 52 62 72 82 93