OPR 3001 Rugged Handheld Laser Scanner Specifications Manual
Opticon OPR 3001 Specifications Manual All information subject to change without notice. Document History Model Number: OPR 3001 Specification Number: SS06106 Edition: 2 Original Spec Number: SS06080 Date: 2006-12-27 Copyright 2007 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Opticon OPR 3001 Specifications Manual Contents 1. Abstract.................................................................................................................................... 6 2. Overview .................................................................................................................................. 6 3. Physical Features.................................................................................................................... 7 3.1. Dimensions .................
Opticon OPR 3001 Specifications Manual 8.2.1. Settings and Communication ................................................................................................. 23 8.2.2. Interface Circuit...................................................................................................................... 23 8.3. Wedge Interface Specification ....................................................................................... 23 8.3.1. Settings and Communication ..........................
Opticon OPR 3001 Specifications Manual 16.1. Laser Safety...................................................................................................................38 16.2. Product Safety ............................................................................................................... 38 16.3. EMC ............................................................................................................................... 38 16.4. RoHS ................................................
Opticon OPR 3001 Specifications Manual 1. Abstract This manual provides specifications for the OPR 3001 handheld laser barcode scanner. 2. Overview The OPR 3001 is a rugged handheld laser barcode scanner with protection against dust and splashing water to ensure reliable operation in harsh environments. The OPR 3001 is enclosed in a rugged housing sealed to IP-54 standards that withstands repeated drops of up to two meters onto concrete.
Opticon OPR 3001 Specifications Manual 3. Physical Features 3.1. Dimensions W 68 X D 150 X H 155 mm (except protruding portion) 3.2. Weight 230g max (excluding cable). 4. Environmental Specifications 4.1. Operating Temperature and Humidity Temperature: -10 to +60° C Humidity: 5 to 90% RH 4.2. Storage Temperature and Humidity Temperature: -30 to +70° C Humidity: 5 to 90% RH 4.3.
Opticon OPR 3001 Specifications Manual Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.9 Resolution: 0.25 mm Symbology: 9-digit Code-39 Quiet Zone: 10 mm N/W Ratio: 1:2.5 Distance: 100 mm from the edge of scanner Angle: α = 0° β = 15° γ = 0° Curvature: R=∞ Power supply voltage: 6.0 V Direct light or specular reflection light from a source should be prevented from entering the acceptance area. 5. Electrical Specifications 5.1.
Opticon OPR 3001 Specifications Manual 6. Optical Specifications 6.1. Laser Scanning Specification Parameter Specification Unit Light-emitting Element Red laser diode - Emission Wavelength 650 ±10 (25° C) nm Light Output 1.0 or less mW Scanning Method Bi-directional scanning - Scanning Speed 100 ±20 scans/s Scan Angle Scan angle: 54 ±5 ° Effective scan angle: 44 (Min) ° 6.2. Laser Scanning Standard 6.2.1.
Opticon OPR 3001 Specifications Manual 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient Temperature and Humidity 21º C/70º F, 60% RH Ambient Light 500 to 900 lx Background Barcode = black Space = white Margin = white Background of label = black Power Supply Voltage 6.0 V (RS-232C) / 5.0 V (USB and Wedge) Decoding Test Approve the performance when decoding is successful in all ten tests.
Opticon OPR 3001 Specifications Manual 7.2. Scan Area and Resolution The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Scan area and resolution (in mm) Resolution Symbology PCS Quiet Zone Digit Decode depth (mm) 1.0 mm CODE-39 0.9 25 mm 1 30 - 590 0.5 mm CODE-39 0.9 18 mm 3 10 - 360 0.25 mm CODE-39 0.9 10 mm 8 10 - 200 0.15 mm CODE-39 0.9 7 mm 10 10 - 90 0.127 mm CODE-39 0.
Opticon OPR 3001 Specifications Manual 7.3. Pitch, Skew, and Tilt α = 35° 35° α = 7.3.1.
Opticon OPR 3001 Specifications Manual 7.3.2.
Opticon OPR 3001 Specifications Manual 20° γ = γ = 20° 7.3.3. Tilt Angle γ = ±20° Figure 6: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 60 mm from the edge of the scanner Label: Pitch Angle, Skew Angle, Dead Zone PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39, Quiet Zone = 10 mm N/W Ratio = 1:2.5 Tilt Angle PCS = 0.9, Resolution = 0.
Opticon OPR 3001 Specifications Manual 7.4. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.
Opticon OPR 3001 Specifications Manual 8. Interface Specifications 8.1. RS-232C Interface Specification 8.1.1. Settings and Communication Reading menu barcodes [ZZ] + [U2] + [ZZ] can set the RS-232C interface default. • Item [U2] setting Baud rate 9600 BPS Start/stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake Flow Control Time Out Indefinitely You can change the communication condition using the menu barcode. 8.1.2.
Opticon OPR 3001 Specifications Manual 8.1.3. Interface Circuit Figure 8: Interface circuit 8.1.4.
Opticon OPR 3001 Specifications Manual 8.1.5. Communication Format Figure 10: Communication format 8.1.6. Handshaking Select handshaking options using the menu or command listed below. Handshaking Menu/Command No handshake P0 BUSY/READY P1 MODEM P2 ACK/NAK P3 ACK/NAK NO RESPONSE P4 a) No Handshaking The scanner attempts the communication regardless of the state of the host computer.
Opticon OPR 3001 Specifications Manual The scanner stays ON (is able to receive data) except during certain parts of the process, such as receiving data (buzzer command execution), transmitting data, and menu processing. The scanner checks the CTS line before transmitting data. When it is ON, the scanner transmits data. When it is OFF, the scanner waits for it to turn ON within a set time.
Opticon OPR 3001 Specifications Manual c) MODEM The scanner turns CS line ON before transmitting data. Other processes are the same as BUSY/READY.
Opticon OPR 3001 Specifications Manual d) ACK/NAK After data has been transmitted, the scanner expects to receive one of the following responses from the host: • ACK response—Action: The scanner completes transmission with the good-read buzzer and returns to the initial state. • NAC response—Action: The scanner sends the data again and waits for the response from the host. • DC1 response—Action: The scanner returns to waiting for the trigger, if it has a trigger (the initial state).
Opticon OPR 3001 Specifications Manual e) ACK/NAK NO RESPONSE When no response from the host is received within the setting time, the scanner assumes an ACK response, and returns to the initial state without the error buzzer. The other actions are the same as ACK/NAK.
Opticon OPR 3001 Specifications Manual 8.2. USB Interface Specification 8.2.1. Settings and Communication Reading menu barcodes [ZZ] + [SU] + [ZZ] can set the USB interface default. The OPR 3001 USB model uses a full-speed USB interface. 8.2.2. Interface Circuit Figure 18: USB interface circuit Do not operate the keyboard while the scanner is transmitting the data to the host; it may cause data transactions to fail. 8.3. Wedge Interface Specification 8.3.1.
Opticon OPR 3001 Specifications Manual 9. Cable and Connector 9.1. Cable Specifications 9.1.1. RS-232C Cable (Standard specification) Type: Straight Diameter: Φ4.8 ±0.5 mm Length: 1500 ±50 , -0 mm Cores: 8 insulated wires, 1 conductive wire Weight: Approximately 80 g Figure 19: RS-232C cable a) Pin Assignment Pin No Signal Name Notes 1 NC Open (not assigned) 2 TXD 3 RXD 4 --- 5 GND 6 --- 7 CTS 8 RTS 9 NC Pin no. 6 and jumper Pin no.
Opticon OPR 3001 Specifications Manual 9.1.2. USB Cable (Standard specification) Type: Straight Diameter: Φ4.8 ±0.
Opticon OPR 3001 Specifications Manual 9.1.3. Wedge Cable (Standard specification) Type: Y cable Diameter: Φ4.8 ±0.
Opticon OPR 3001 Specifications Manual 9.2. Scanner Connector Specification CN801 (13-pin) Signal Name Pin Number RS-232C USB Wedge 1 NC VCC VCC 2 R×D NC NC 3 T×D NC NC 4 NC NC CPU_CLK 5 NC NC CPU_DATA 6 GND GND GND 7 NC USB+ NC 8 NC USB- NC 9 NC NC KB_DATA 10 NC NC KB_CLK 11 CTS NC NC 12 RTS NC NC 13 VCC NC NC 10. Readable Barcodes 10.1. Menu Barcodes: Default Settings Default menu barcodes set the scanner to factory defaults.
Opticon OPR 3001 Specifications Manual * If you are using software version TS01Y04 or later, it is not necessary to configure the foregoing settings.
Opticon OPR 3001 Specifications Manual 10.2.
Opticon OPR 3001 Specifications Manual Notes: • In the “Reading” column, “” means “Enable reading” and “X” means “Disable reading.” • In the “Transmit code length” column, “” means “Transmit code length” and “X” means “Do not transmit code length.” • In the “Transmit CD” column, “” means “Transmit check digit” and “X” means “Do not transmit check digit.” • In the “Calculate CD” column, “” means “Calculate check digit” and “X” means “Do not calculate check digit”. 10.3.
Opticon OPR 3001 Specifications Manual 11. Serial Number The serial number as shown below is affixed to the scanner.
Opticon OPR 3001 Specifications Manual 12. Packaging Specifications 12.1. Individual Packaging Specification Put the scanner in a protective foam bag and place it in a single packing box. The scanner shown is an RS-232C unit. Descriptions on an individual packaging box label differ, depending on the interface type. The “RO” mark may be indicated on the upper side of the individual packaging box label.
Opticon OPR 3001 Specifications Manual 12.2. Collective Packaging Specification The scanner shown is an RS-232C unit. Descriptions on a collective packaging box label differ, depending on the interface type. The “RO” mark may be indicated on the upper side of the individual packaging box label.
Opticon OPR 3001 Specifications Manual 13. Durability 13.1. Electrical Noise No malfunction should occur when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp) is added to a power supply line. Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.9 Resolution: 0.25 mm Symbology: 9-digit Code-39 Quiet Zone: 10 mm N/W Ratio: 1:2.5 Distance: 100 mm from the edge of scanner Angle: α = 0° β = 15° γ = 0° Curvature: R=∞ Power Supply Voltage: 6.0 V (RS-232C) / 5.0 V (USB and Wedge) 13.
Opticon OPR 3001 Specifications Manual 13.3. Shock 13.3.1. Product Drop Test No malfunction should occur after the following drop test. As shown below, drop the scanner from 200 centimeters above the concrete floor (three times from each of 6 angles). Figure 25: Product drop test 13.3.2. Shock: Individual Package Drop Test No malfunction should occur after the following drop test.
Opticon OPR 3001 Specifications Manual 13.6. Cable Strength 13.6.1. Cable Pull Strength Affixed the scanner to an immovable object and pulled it using a force of 49N (5.0 kgf) for 1 minute. Observed no abnormality in either structure or performance. 13.6.2. Cable Bend Strength As shown below, added a load of 4.9N (500 g) to a cable then bent it at an angle of 90 degrees to both right and left.
Opticon OPR 3001 Specifications Manual 15. Auto Trigger (Option) The OPR 3001 has an optional auto trigger setting, which starts barcode reading automatically by using sensor detection. When auto trigger is enabled, a laser beam is emitted and points to the auto trigger area. The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used. Auto trigger distance: 40 mm from the edge of the scanner.
Opticon OPR 3001 Specifications Manual 15.1.1. Auto Trigger Settings Functions SET Disable auto trigger Enable auto trigger END Menu labels Menu codes _ZZ_ _+F_ _+I_ _ZZ_ ZZ +F +I ZZ 16. Regulatory Compliance 16.1. Laser Safety The scanner emits laser beams. • JIS C6802: 2005: Laser class 1 • IEC 825-1/EN 60825-1: Laser class 1 • FDA CDRH Laser class I. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No.
Opticon OPR 3001 Specifications Manual 17. Safety 17.1. Shock • Do not throw or drop the scanner. • Do not place heavy objects on the cables. 17.2. Temperature Conditions • Do not use the scanner at temperatures outside the specified range. • Do not pour boiling water on the scanner. • Do not throw the scanner into the fire. • Do not forcibly bend the cables at low temperatures. 17.3. Foreign Materials • Do not immerse the scanner in liquids. • Do not subject the scanner to chemicals. 17.4.
Opticon OPR 3001 Specifications Manual 18.