Connection sequence
for single cradle:
Place the cradle in normal office conditions,
avoid a place under strong light.
Disconnect the power supply.
Set the required DIPswitches for
baud rate and function.
Connect the interface cables.
Connect the power supply.
Place the PHL2700 terminal in the cradle.
!
!
!
!
2.6.1 Terminal to computer
2.6.2 Single cradle to computer
2.6.3 Cradle network
Connection sequence
for cradle in network:
Set all cradles to the same baud rate (by
DIPswitch)
Only 1 cradle in the network will be
connected to the PC through one RS232
cable. On this cradle the DIPswitch for RS232
connection must be enabled. Through this
connection all cradles can communicate to
the PC.
A maximum of 16 cradles can be connected
in a network through RS485 cables. For the
cradles that are not directly connected to the
PC the DIPswitch for RS232 connection
must be set to off.
The first and the last cradle in the network
must have the termination resistors set by
dipswitch.
3 POLE
CONNECTOR
RS 232
DB9
HOST
PHL 2700
DB9
CRADLE
RS 232
DB25 / DB9
HOST
2.6 INSTALLING IN A SYSTEM
RS 485
sw 1 = off
sw 2 = off
sw 3 = off
RS 232
TRANSMISSION
HOST
TERMINATED RS 485
sw 1 = on
sw 2 = on
sw 3 = on
RS 485 TERMINATED
sw 1 = off
sw 2 = on