User guide

USERS MANUAL PHL2700 TERMINAL / IRU2700 CRADLE
21
When the terminal has a problem with
reading the label:
The resolution of the bar code is too
high.
Decrease the distance between the bar
code and the terminal.
The angle between the label and the
terminal is too high.
Change the angle between the bar code
and the terminal.
The distance is too far or too close.
Change the distance between the bar
code and the terminal.
The bar code is larger than the laser
beam.
Try moving the terminal a bit further away
from the bar code.
The read window is dirty.
Clean the read window of the terminal.
The read window is scratched.
The terminal needs service.
The type of the bar code label is not
enabled.
Enable the bar code symbology in the
application program.
?
?
?
?
?
?
?
When the terminal is placed in the cradle,
the main battery is not charged.
Red LED indicator on the terminal is
flashing on and off.
The charging contacts of the cradle and/or
the terminal are dirty. Clean the contacts.
Red LED indicator on the terminal is not
turned on.
The typical charging procedure requires
the terminal to be switched off. Check this.
The cradle needs a rechargeable battery
pack to charge. When a battery holder for
dry cell batteries Is used, the charger
does not work at all.
There is no contact between the terminal
and the cradle. Try again to place the
terminal properly, or clean the contacts of
either the cradle and/or the terminal.
Replace the battery pack and try again.
The rechargeable battery pack is still not
charged. Red LED indicator on terminal
keeps on.
The charger for the battery pack is
probably defect. The cradle will need
service.
?
?
?
7.2 READ OPERATION
PROBLEMS
7.3 BATTERY CHARGING
PROBLEMS