User's Manual

CRD-3301 SS08xxx
17
12. Packaging Specifications
12.1. Individual Packaging Specufuactions
Size of the package: 163 (W) × 252 (D) × 123 (H) (mm)
*T.B.D
Figure 15: Individual packaging specifications
12.2. Collective Packaging Specufuactions
Size of the package: 260 (W) × 830 (D) × 255 (H) (mm)
*T.B.D
Figure 16: Collective packaging specifications
Note: The “RO” mark labeled on the package tray or package box guarantees that the applicable product
has passed our test of RoHS restrictions compliance (the restriction of the use of certain
hazardous substances in electrical and electronic equipment, 2002/95 EC). However, this
document does not have any legal weight in the European Union.
13. Environmental Specifications
13.1. Operating Temperature and Humidity
Operating temperature: 0 to 40° C (Excluding AC adapter)
humidity: -25 to RH (No condensation, no frost)
13.2. Storage Temperature and Humidity
Storage temperature: -20 to 60° C
humidity: 20 to 90% RH
13.3. Electrical Specifications
Withstand voltage: AC 1500V / 60 seconds 10mA or less
Insulation resistance: DC500V 2M
Leak current: 250μA or less / AC 250V 60Hz
Line noise: ±1kV
or higher
Static noise: No destruction: ±15
KV (air discharge, direct)
No malfunction: ±8kV (air discharge, direct)
±8kV (air discharge, direct)
*Measurement environment: Use electrostatic testing device compliant with IEC 61000-4-2.
(150pF, 330)
13.4. Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 75 cm onto a concrete floor.
(three times in each of 6 angles).
13.5. Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop an individually packaged scanner from a height of 75 cm onto a concrete floor once
on its 1 corner, 3 edges, and 6 sides (10 total drop tests).
13.6. Vibration Strength
No malfunction occurred after the following vibration test.