User Manual

H-1311-BTH SS08xxx
17
12. Environmental Specifications
12.1. Operation Temperature and Humidity
-10°C to 50°C (except when charging)
20 to 85% RH (No condensation, no frost)
12.2 Storage Temperature and Humidity
-20°C to 60°C
20 to 85% RH (No condensation, no frost)
12.3. Ambient Light Immunity
Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:
Incandescent light 4000 lx
Fluorescent light 4000 lx (except high frequency fluorescent light)
Sunlight 80000 lx
12.4. Dust and Drip Proof
IEC: IP54
12.5. Vibration Strength
No malfunction occurred after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6 m/s
2
(2.0G) for 60 minutes in non-operating state. Repeat this
routine in each X, Y, Z direction once for 60 minutes each.
12.6. Vibration Strength (with individual packaging)
No malfunction occurred after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6 m/s
2
(2.0 G) for 60 minutes in individually packaged state.
Repeat this routine in each X, Y, Z direction once for 60 minutes each.
12.7. Drop Test
No malfunction occurred after the following test.
Drop Test: Drop the scanner from 150cm above the concrete floor.
(6 sides, 3 times each)
12.8. Drop Test (with individual packaging)
No malfunction occurred after the following test.
Drop Test: Drop an individually packaged scanner from a height of 150 cm onto a
concrete floor once on its 1 corner, 3 edges and 6 sides. (10 drop tests in total.)