User's Manual

OPN-3102n
1st
15
SPECIFICATIONS MANUAL
8 Technical Specifications
Aim the laser light at the center of a code to scan it. The conditions for technical specifications are as
follows, unless otherwise specified in each section.
<Conditions>
Ambient Temperature and Humidity Room temperature, room humidity
Ambient Light 100 ~200 lux (on the surface of a barcode)
Angles Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0°
Curvature R =
Power Supply Voltage 5.0 V (USB)
PCS (1D and 2D) 0.9 or higher
Scanning Test Accept the performance with 90% or more success rate
for 10 tries of scan. One reading should be 2 seconds.
Barcode Test Sample (1D and 2D)
Specified below.
< Test chart >
For 1D codes, OPTOELECTRONICS test samples
For GS1 Databar, stacked codes and 2D codes, printed by a dedicated printer for barcode
β
γ
+
+
+
-
-
-
Figure 5: Scanning conditions
Center of image