9.5 Vibration Strength (without packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated
velocity of 19.6m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in non-operating state.
Repeat this in each X, Y and Z direction.
9.6 Vibration Strength (in individual packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated
velocity of 19.6 m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in individually packaged state.
Repeat this in each X, Y and Z direction.
9.7 Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner 18 times in total (3 times at each 6 face), from a height of 150 cm
onto a concrete floor as shown below.
150cm
Figure 11: Drop Test
9.8 Drop Impact Strength (in individual packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges,
and 6 faces, from a height of 150 cm onto a concrete floor.
9.9 Electrostatic Discharge Immunity
Air discharge ±8 kV max. (No malfunction)
±15 kV max. (No destruction)
Measurement environment An electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance 330
Charging capacitor 150 pF