Operation Manual

English
55
ADDITIONAL INFORMATION
Warning indicators
When the warning indicators (see below) light up or ash, the projector will automatically shutdown:
"LAMP" LED indicator is lit red and if "On/Standby" indicator ashes amber.
"TEMP" LED indicator is lit red and if "On/Standby" indicator ashes amber. This indicates the
projector has overheated. Under normal conditions, the project can be switched back on.
"TEMP" LED indicator ashes red and if "On/Standby" indicator ashes amber.
Unplug the power cord from the projector, wait for 30 seconds and try again. If the warning indicator light up or
ash, please contact your nearest service center for assistance.
LED lightning messages
Message
Power LED Power LED
Temp-LED
Lamp-LED
(Red) (Green or Blue) (Red) (Red)
Standby state
(Input power cord)
Steady light
Power on (Warming)
Flashing
(0.5 sec off /
0.5 sec on)
Power on and Lamp
lighting
Steady light
Power off (Cooling)
Flashing
(0.5 sec off /
0.5 sec light). Back
to red steady light
when cooling fan
turns off.
Quick Resume (100
secs)
Flashing
(0.25 sec off /
0.25 sec light)
Error (Over temp.) Flashing
Error (Fan failure) Flashing Flashing
Error (Lamp failure) Flashing
Power off:
Power Off
Power Off?
Press power key again.
Lamp warning:
Warning
Lamp Warning
Lamp life exceeded.