TEMPERATURE PROGRAMMING
• Temperature adjustment is made with four levels of setpoint values that are
independent for each adjustment zone for summer and winter operation and can be
confi gured via this menu.
• After accessing the menu indicated by the symbol
, use the and arrows to
select the current zone temperature (T0, T1, T2 o T3) and the current mode (summer
or winter) that has to be modifi ed.
• Press [OK] to enable the temperature (fl ashing) modifi cation and use the arrows
and
to modify it.
• Press [OK] to fi nalise the modifi cation.
Note: in summer operating mode, T0 temperature cannot be confi gured because
it corresponds to the OFF state.
• The accepted intervals for the temperatures are given below:
Winter operation
Temperatures minimum [°C] maximum [°C] default
T0 2.0 T1 5.0
T1 T0 T2 15.0
T2 T1 T3 18.0
T3 T2 35.0 20.0
Summer operation
Setpoint
minimum setting
[°C]
maximum setting
[°C]
default setpoint
values
T0 - -
SWITCHED OFF
T1 10 T1 23.0
T2 T1 T2 24.0
T3 T2 35.0 25.0
12