Operation Manual

- 62 -
Instruction Manual Athena
English
TELEPHONE CONTROL
The chronothermostat can be operated via a telephone combiner voltage-free contact,
with a resistance of < 100
).
There are two operating modes:
°
open contact; normal operation;
°
closed contact; the zones enter the OFF state until the successive opening of the
contact, entering the state existing prior to closing the contact.
When the symbol
is displayed on the main page, it means that the telephone
contact is closed (OFF state).
NETWORK CONFIGURATION
By default, the Athena chronothermostat is only confi gured for zone 1, confi guring
the internal sensor as sensor and the unit relay as actuator.
The network has to be confi gured to use the remote wireless actuators or over the
bus, or remote sensors over the bus.
To accomplish this, the remote sensor and/or remote actuator is selected for the
desired zone from the “Confi guration of each adjustment zone” menu, then prior to
pressing the [OK] key, to start up the confi guration procedure, the remote sensor and/
or actuator is confi gured (see the associated instructions).
After pressing the [OK] key the unit will use the “OK” message to indicate that the
zone confi guration has been correctly confi gured.
ERROR MESSAGES
Poor operating conditions may occur during normal operation that prevent normal
operation.
For example, if an internal, external or remote sensor develops a fault, the temperature
eld of the corresponding sensor will display [--.-], disable the adjustment for this
zone and force the associated actuator to go to the OFF state.
If any bus peripheral communications errors occur, the following message will be
displayed onscreen: “PERIPHERAL ERRORS ON BUS Z …”.
The zones will have to be tested in order to identify the problem (see the note in the
confi guration menu for each of the adjustment zones).