1/ Description
AEMI CR1 Clean Room RF Absorbers have a clear latex
coating that completely covers the absorber, including
the bottom. They are treated for use in class 100,000
clean room environments. This treatment does not ne-
gatively affect the overall performance. These absorbers
are used extensively in satellite assembly facilities as well
as other aerospace applications.
AEMI CR2 Clean Room RF Absorbers have a rubberized
treatment that completely covers the absorber, including
the bottom. They are treated for use in class 10,000
clean room environments. This treatment does not ne-
gatively affect the overall performance. These absorbers
are used extensively in satellite assembly facilities as well
as other aerospace applications.
2/ Unique Manufacturing Process
After the standard manufacturing process, these ma-
terials undergo further treatment to remove any loose
debris from the manufacturing process. The material is
coated with a special latex binder or plasticized coating
(depending on class).
3/ Specifi cations
AEP-4-CR AEP-6-CR AEP-8-CR AEP-12-CR AEP-18-CR AEP-24-CR AEP-36-CR AEP-48-CR
Height in 4 6 8 12 18 24 36 48
cm 10.2 15.2 20.3 30.5 45.7 61 91.4 121.9
Pyramids per block 144 64 64 36 16 9 4 4
@ 125 MHz dB 28
@ 250 MHz dB 30 32 35
@ 500 MHz dB 30 35 37 40
@ 1.0 GHz dB 30 35 37 40 42 45
@ 3.0 GHz dB 30 33 37 40 45 45 50 50
@ 6.0 GHz dB 35 37 45 45 50 50 50 50
@ 10.0 GHz dB 40 40 50 50 50 50 50 50
@ 13.0 GHz dB 45 50 50 50 50 50 50 50
@ 15.0 GHz dB 50 50 50 50 50 50 50 50
Power Watt/in
2
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Watt/m
2
775 775 775 775 775 775 775 775
Weight lbs/pc. 2.5 3 4.5 6 9 13.5 18.5 25
kg/pc. 1.1 1.4 2 2.7 4.1 6.1 8.4 11.3
Absorption @ Normal Incidence
AEP-6-CR mechanical drawing
6”
1”
2”
24”
24”