Owner's manual

122
System specifications Multi-probe set-up*
30 dBi AUT
PEAK GAIN ACCURACY
0.8 GHz - 1 GHz ± 0.5 dB
1 GHz - 6 GHz ± 0.5 dB
6 GHz - 18 GHz ± 0.5 dB
Repeatability ± 0.3 dB
- 20 dB SIDELOBES ACCURACY
0.8 GHz - 1 GHz ± 0.6 dB
1 GHz - 6 GHz ± 0.6 dB
6 GHz - 18 GHz ± 0.7 dB
- 30 dB SIDELOBES ACCURACY
0.8 GHz - 1 GHz ± 1.3 dB
1 GHz - 6 GHz ± 1.2 dB
6 GHz - 18 GHz ± 1.3 dB
* Table refers to radiation pattern < ± 60 deg. Specications given according
to the following assumptions:
• Controlled temperature and humidity during measurement
• Specications on radiation pattern are given for a normalized pattern
• Measurements inside an anechoic chamber
• Peak gain is given for a ± 0.3 dB gain error on the reference antenna
No averaging
Typical measurement time for single beam antenna
(1)
Multi-probe set-up*
Frequency Number of measured Measurement
frequencies time (in hours)
3 GHz 5 0.1
3 GHz 10 0.2
18 GHz 5 3
18 GHz 10 4.5
(1) AUT size 5 x 5 m
System specifications Single-probe set-up*
30 dBi AUT
PEAK GAIN ACCURACY
0.8 GHz - 1 GHz ± 0.5 dB
1 GHz - 6 GHz ± 0.5 dB
6 GHz - 18 GHz ± 0.5 dB
18 GHz - 40 GHz ± 0.5 dB
Repeatability ± 0.3 dB
- 20 dB SIDELOBES ACCURACY
0.8 GHz - 1 GHz ± 0.5 dB
1 GHz - 6 GHz ± 0.5 dB
6 GHz - 18 GHz ± 0.5 dB
18 GHz - 40 GHz ± 0.5 dB
- 30 dB SIDELOBES ACCURACY
0.8 GHz - 1 GHz ± 1.2 dB
1 GHz - 6 GHz ± 1.0 dB
6 GHz - 18 GHz ± 1.1 dB
18 GHz - 40 GHz ± 1.3 dB
* Table refers to radiation pattern < ± 60 deg. Specications given according
to the following assumptions:
• Controlled temperature and humidity during measurement
• Specications on radiation pattern are given for a normalized pattern
• Measurements inside an anechoic chamber
• Peak gain is given for a ± 0.3 dB gain error on the reference antenna
No averaging
Typical measurement time for single beam antenna
(1)
Single-probe set-up*
Frequency Number of measured Measurement
frequencies time (in hours)
3 GHz 5 2
3 GHz 10 2.5
18 GHz 5 21
18 GHz 10 23
(1) AUT size 5 x 5 m
Measurement time comparison
5