- Underground Sprinkler Installation Guide
- Design Section 1 - Why Install?
- Design Section 2 - Check Local Codes
- Design Section 3 - Measure Water Flow
- Design Section 4 - Measure & Draw Property
- Design Section 5 - Select Heads
- Design Section 6 - Head Placement
- Design Section 7 - Creating Watering Zones
- Design Section 8 - Plan Valve Placement
- Design Section 9 - Diagram Pipe Layout
- Design Section 10 - Plan Timer Location
- Design Designing System - Helpful Tools
- Design Layout Graph Paper
- Installation - Helpful Tools
- Installation Section 1 - Installation
- Installation Section 2 - System Layout
- Installation Section 3 - Connect to Water Main
- Installation Section 4 - Backflow Prevention
- Installation Section 5 - Dig Trenches
- Installation Section 6 - Working with Pipe
- Installation Section 7 - Install Main Line
- Installation Section 8 - Install Manifold
- Installation Section 9 - Connect Zones
- Installation Section 10 - Instll Risers & Heads
- Installation Section 11 - Connecting Sprinkler Wire
- Appendix A - Charts
- Appendix A - Selecting the Components
- Appendix A - Parts List
Example – We have determined that our home
has a “Main Line” size of 3/4” with
a “Static Water Pressure” of 60 psi. Based on
this information, and using the Quick
Reference, we see that we cannot use
more than three Voyager II
®
sprinklers in
the same zone.
STEP 2: Identifying Sprinklers in a Zone
Begin grouping large area heads, ensure you do not ex-
ceed your “Maximum Heads per zone number.”
Example – Since we determined (in our example above) that 3 Voyager II
®
heads
is the maximum zone capacity, we grouped all large area heads into 2 zones.
Step 3:
Medium and Small Area Head Zones
Repeat steps 1 & 2 to determine and identify zones for Medium Areas Heads. Repeat again for
Small Area Heads.
Step 4: Number Each Zone
• Assign a number to each zone.
Planning & Design
Sprinkler System Layout & Installation Guide
9
WATER PRESSURE (PSI)
SCH.
40
PVC
Gear Drive
30 PSI 40 PSI 50 PSI 60 PSI
12
22
2
3
3
4
Q
UICK REFERENCE – MAXIMUM HEADS PER ZONE ESTIMATES
MAIN
LINE
SIZE
V
oyager II
®
Saturn III
®
07WTM003045 53251-01 rE.qxd 3/2/07 2:30 PM Page 9