Owner's Manual

Press the – button to reverse clock time
(hold button for quick reverse).
START TIME
Press the + button to advance start time
(hold button for quick advance).
Press the – button to reverse start time
(hold button for quick reverse).
HOW LONG
Set watering duration from 1 to 240 minutes using
the + and – buttons.
HOW OFTEN
Set watering frequency as every 6 hrs, 12 hrs, or
from 1 to 7 days using the + and – buttons. 1 is
every day, 2 is every other day etc. up to 7 days.
AUTO
Timer waters according to programmed time,
duration, and frequency.
RAIN DELAY
When in AUTO, press + button for 24 hrs,
48 hrs, or 72 hrs.
Screen will flash between clock and hours
remaining before programmed cycle resumes.
To remove rain delay, turn dial to OFF and then
back to AUTO.
MANUAL/HAND WATERING
To water without interrupting the set cycle, press
INSTALLING THE BATTERIES
Remove the tray on the back of the timer by
sliding it out.
Insert two AA (1.5V) alkaline batteries
(not included) and replace the tray.
Replace batteries when low battery icon appears.
INSTALLATION
Attach timer to an outdoor hose faucet and turn
on after programming.
PROGRAMMING THE TIMER
Rotate the dial to positions indicated for setup.
SET CLOCK
Press the + button to advance clock time
(hold button for quick advance).
PN 62062-24 rD
dual outlet dIGItal tImer
PROGRAMMING FOR THE DIGITAL
PORT OF THE TIMER
THE MANUAL PORT CANNOT BE
PROGRAMMED DIGITALLY
[MANUAL] button and then use + and – buttons to
set from 1 to 240 minutes.
To remove manual watering (turn off),
turn dial to OFF.
To resume programmed cycle turn the
dial back to AUTO.
MANUAL PORT
The manual port of the timer gives access to the
hose faucet without interrupting the programmed
cycle of the digital port.
Open the valve in the port by turning the lever
counterclockwise to the open position.
Close the valve by turning the lever to the
closed position.
TROUBLESHOOTING
Water does not come on at desired time.
Check if:
Clock is set to correct time including AM and PM
Start time is set to desired time including
AM and PM
Rain Delay is on
Timer does not water.
Check if:
Faucet is on
Timer is set to AUTO
Hose faucet is on
Batteries are low
Clock is set to correct time including AM and PM
Rain Delay is on
Water won’t turn off.
Check if:
Watering duration is set to desired time
Start times begin after previous watering cycle
has run through all stations and set durations
For bypass/manual port: close valve
Working Water Pressure
Minimum: 25 psi Maximum: 100 psi
Working Temperature
Maximum: Do not exceed 120 degrees F
Minimum: Keep from freezing
Warnings
For outdoor use with cold water only.
© 2008 Orbit Irrigation Products,
Inc. All rights reserved. All trade
names are registered trademarks
of respective manufacturers listed.
Orbit
®
Irrigation Products, Inc.
North Salt Lake, UT 84054
1-800-488-6156