User Manual

41.
40.
FCC ID:
2AAWI-MYEYE2
CE OverensstemmelseOverholder direktivet om
restriktioner i brugen af
farlige stoffer (materialer
og komponenter)
Overholder direktivet om
bortskaffelse af affald af
elektrisk og elektronisk
udstyr - kontakt OrCam
vedr. korrekt bortskaffelse
Se brugervejledningen.
Safety and Warnings.
Before using the OrCam device, read these precautions carefully to avoid dangerous situations and to ensure ideal
performance of your device.
Handle your OrCam device with care. It can be damaged if dropped, burned, punctured, or crushed. Do not open the outer
casing of the device.
The OrCam device is designed to work in ambient temperatures between 32⁰F and 104⁰F (0⁰C and 40⁰C) and in normal
conditions (Relative Humidity of 10% to 90% RH and Atmospheric Pressure of up to 2000m above sea level (700hPa)). The
device can be damaged if used outside of this range. Store and transport in a cool, dry place (32⁰F to 104⁰F (0⁰C to 40⁰C)
and Relative Humidity of 5% to 90% and atmospheric pressure of 700hPa to 1060hPa)). The OrCam device is water resistant
but not waterproof. This means the device can withstand light rain or drizzle for short periods of time, although it is not
recommended. Do not use the OrCam device in heavy rain, at the beach or swimming pool, or in or near a bathtub or shower.
Do not submerge the OrCam device in any liquid. The OrCam device meets the standards of IP Code: IP22.
Should you have a problem operating the OrCam device, if the case or lens is cracked, or if you believe there is something
wrong with the device, please contact support and do not attempt to repair it by yourself. Only qualied OrCam personnel may
repair or service your device. Unauthorized repairs may void your warranty.
Do not attempt to replace the battery; you may damage it, which could cause overheating and even injury. The battery is
designed to last for two years of average use (one charging cycle per day on average) after which it may need to be replaced.
Use only the charger supplied with your OrCam device. Using another charger may void your warranty and could cause severe
injury.
Do not force a connector into a port or apply excessive pressure to a button. This may cause damage that is not covered
under the warranty. If a connector does not insert easily, check for obstructions in the port and verify that you have the correct
connector for that port. Do not combine with software, hardware, or other equipment not supplied by OrCam. Exposing the
device to magnetic elds may damage the unit or erase your data.
When using the OrCam device or charging the battery, it is normal for the device to get warm. If the unit becomes excessively
hot, leaks, or gives off a burning smell, turn the device off immediately and contact OrCam Support.
OrCam MyEye meets the standard requirements in the US and EU for Class 1 medical devices. OrCam recommends keeping
the OrCam MyEye’s magnets at least 6 in./15 cm. away from any implantable cardiac equipment. If you have specic questions
about use alongside an internal pacemaker and/or debrillator, please consult your medical professional. Do not use the
OrCam device to read medication labeling.
Cleaning.
Clean your device if you feel it is dirty or transferred between users. Never touch the camera lens with your nger. Clean the
lens only with the supplied microber cloth and eyeglass cleaning uid. Do not use any abrasive materials. Do not expose the
device to chemicals, such as household cleaners, aerosol sprays, solvents, alcohol, or ammonia. If you experience an allergic
reaction to any of the elements of the OrCam device, contact a medical professional.
IEC 62366-1:2015. EN IEC 60601-1-2. EN 62304. RoHS Directive 2011/65/EU. WEEE. EN ISO 14971:2016. Council
Directive 93/42/EEC of 14 June 1993 concerning medical devices.