Instruction manual

7
ENGLISH
SPECIFICATIONS
Caliber Click-B Date Day of week Hand winding Daily accuracy Remark1*
DB 46A
–– +25~-15s/day
DW 48D
––+25~-15s/day
9:00PM-2:00AM
EM 469
○○
+25~-15s/day
9:00PM-4:00AM
ER 487
––+25~-15s/day
9:00PM-2:00AM
NP 558
○○
+40~-30s/day
8:30PM-2:00AM
NQ 559
○○
+40~-30s/day
8:30PM-4:00AM
NR 557
+40~-30s/day
8:30PM-0:30AM
PF 597
+40~-30s/day
8:30PM-0:30AM
PM 599
○○
+40~-30s/day
8:30PM-4:00AM
(1) Vibrations: 21,600 vibrations/1 hour
(2) Number of jewels: 21 jewels
(3) Running time: More than 40 hours
(4) Shock-proof bearings to protect the balance with hairspring from shocks.
The stated daily accuracy is in the following conditions:
After 24 hours at room temperature with the mainspring wound fully and the dial facing up.
Due to the characteristics of the automatic winding watch, the time may deviate from the
stated “daily accuracy” depending on the following conditions: amount of time the watch
is worn each day, position of the watch, movement of your arm, winding condition of the
mainspring.
Product specifications may change without notice, for improvement.
CAUTION
!
* Avoid setting the date during the time periods listed in “Remark1” above since the calendar
changes during this time. If the date is set during this time period, the date may not change
or the watch may malfunction. Be sure to move the hour and minute hands away from this
time period when setting the date.