Connection and Operation
Names and Functions of Brake Pack Parts
q
w
e
r
No.
Name
Factory Setting
Functions
POWER Indicator
(Green)
Lit when 24 VDC is supplied.
ALARM Indicator (Red) Lit when the ALARM output is "OFF."
Motor Output
Select Switch
60
90 W Used to set the motor output.
SINK/SOURCE
Select Switch
SINK
Used to switch between Sink/Source for the control
signal output.
Connection Diagrams
The wiring diagram is for when the SINK/SOURCE select switch is
set to the "SINK" side.
Induction Motors/Reversible Motors
ALARM Output
CCW Operation Input
CW Operation Input
Motor
Motor
(Terminal Box Type)
Black
Brake Pack
Terminal No.
Red
White
Capacitor
Capacitor
GND
Brake Release Input
ON
ON
24 VDC
0.1 A min.
L
AC Power Supply
N
L
AC Power Supply
N
Single-phase 100/110/115 VAC, single-phase 200/220/230 VAC
FG
ON
ON
2
2
1
6
8
5
4
7
9
1
Z2
U2
U1
24 VDC
11
11
Electromagnetic Brake Motors
CW Operation Input
CCW Operation Input
GND
Brake Release Input
Electromagnetic
Brake Motor
Red
White
Black
Capacitor
Orange
Orange
L
N
ON
ON
Brake Pack
Terminal No.
2
24 VDC
0.1 A min.
FG
AC Power Supply
1
10
6
8
5
4
7
9
ALARM Output
11
24 VDC
Single-phase 100/110/115 VAC, single-phase 200/220/230 VAC
Terminal Arrangement for Flush Mounting Socket
Terminal
No.
Signal Name Description
Motor/Capacitor Connect the motor and capacitor.
AC Power Input (L)
Single-phase 100
115 VAC
Single-phase 200
230 VAC
NC Not used. Leave this terminal unconnected.
1
Brake Release Input
2
Not an instantaneous stop but a natural stop
ALARM-RESET Input Reset ALARM Output.
CCW Operation Input
3
Motor runs in the CCW direction during "ON."
DC Power Input
24 VDC input
GND GND
CW Operation Input Motor runs in the CCW direction during "ON."
ALARM Output
Turns "OFF" when the motor's thermal
protector is "open."
Electromagnetic Brake
4
Connect to the electromagnetic brake.
Motor/Capacitor Connect the motor and capacitor.
1 Functions as a brake release input during normal operation, and as an ALARM-RESET
input when the ALARM output is OFF.
2 Releases the electromagnetic brake for electromagnetic brake motors.
3 Not used with an induction motor with four lead wires.
4 Only for electromagnetic brake motors.
Notes:
The input-signal voltage is 24 VDC
10% and 0.1 A or more.
Minimize the length of the motor cable and the input/output signal cable to reduce EMI.
Use a cable of AWG18 (0.75 mm
2
) or more in diameter for the motor cable and power
cable.
Be sure to connect the GND terminal to GND (negative side) of the external controller, or
the unit will not operate.
World