Manual
cleaning agents or solvents,
as this may damage the gasket
of the sapphire crystal.
3. Plug the syringe on the cannula
and inject the water to rinse the
channel. (Fig. B)
4. If necessary, repeat steps 2 and 3
5. Withdraw the tube with the
mounted syringe slowly out of the
channel and, at the same time,
pull the piston of the syringe in
order to remove the water from
the channel
6. To remove residual water from
the channel apply step 1 & 5 only
(Fig. A)
(Fig. B)
Guidelines
Each Oris Aquis Depth Gauge has
been tested and found to comply
with the Oris testing standards.
It is possible that due to physical
damage, inadequate handling
or uncontrollable influence, the
depth indication may not function
properly. These guidelines will
help to make the Oris Aquis Depth
Gauge the best possible dive
companion.
Accuracy of the Depth Gauge
The following parameters interact
with the physical functionality of
the Oris Aquis Depth Gauge and
may slightly influence the accuracy
of depth indication:
Change of ambient air pressure
due to different temperature,
weather conditions and height
above sea level
Temperature difference of
ambient air/water, particularly
the difference in temperature
between the watch and the water
Salinity of the water
Safety Precautions Prior to Dive
Check there is no water residue
(dark grey colour spots) in the
gauging channel. If there is, clean
the channel as explained under
’How to Use the Cleaning Kit’
Ascertain that the Oris Aquis Depth
Gauge has ambient temperature,
i.e. that it has not been exposed
to extreme sunlight or other heat
or cold before the dive
Use the Oris Aquis Depth Gauge
only as a supplemental mechanical
depth gauge, in addition to the
usual diving instruments
Oris declines any responsibility
if these instructions are not
followed. The international guaran-
tee applies as stated in the Oris
Product Manual supplied with
each Oris watch and available on
www.oris.ch
Cleaning Kit Components
The cleaning kit for the Oris
Aquis Depth Gauge contains the
following parts:
1 x syringe 5 ml ➀
5 x cannula ➁
5 x flexible tube ➂ (mounted to
cannula)
How to Use the Cleaning Kit
The kit is designed to clean the
gauging channel and to remove
residual water. Proceed as follows:
1. Feed the flexible tube transversely
towards the channel into the
opening of the sapphire crystal
and push the tube until it reaches
the end of the channel. (Fig. A)
2. Fill the syringe with water
Note: Do not use any aggressive
English
➀
➁
➂