Certifications

T
est
Report
No. AJFS1809009217FF Date: OCT.17, 2018 Page 3 of 6
V. SAMPLE DETAILS
Sample description PVC panel
Color / Density White / About 1.36 kg/m
2
Exposed face:
The front face
MOUNTING METHODS:
The 20-gage, 2-in. (51-mm) hexagonal galvanized steel netting should span the width of the tunnel, then
the specimen shall be placed on the netting
The specimen consisted of 15 pieces of 500mm wide×500mm long x 25.0mm thickness and all sections
jointed end- to- end.
TEST RESULTS
FSI SDI
10
400
RATING:
The National Fire Protection Association Life Safety Code 101, Chapter 10, Section 10.2.3 Interior Wall
and Ceiling Finish Classification”, has a means of classifying materials with respect to Flame Spread and
Smoke Developed when tested in accordance with NFPA 255, ASTM E84, UL 723 Method of Test of
Surface Burning Characteristics of Building Materials”.
International Building Code, Chapter 8, Interior Finishes, Section 803 “Wall and Ceiling Finishes”, was
classified in accordance with ASTM E 84 or UL 723. Such interior finish materials shall be grouped in the
following classes in accordance with their flame spread and smoke-developed indexes.
To be continued….