Installation & Assembly
6
Figure 12
Registration
slot
Screw
Safety cable
Figure 11
5. Loosen the two set screws and remove the
hitch pin and lock pin from the central
shaft/top coupling of the motor assembly.
Doing so will allow the down rod to enter the
central shaft. (Fig. 11)
6. Route wires exiting from the top of the fan
motor through the coupling cover, canopy
cover and canopy and then through the
ball/downrod. Place downrod rubber cover
onto the hanger ball (Fig. 11)
7. Align the holes at the bottom of the downrod
with the holes in the collar on top of the
motor housing. Carefully insert the hitch pin
through the holes in the collar and downrod.
Be careful not to jam the pin against the
wiring inside the downrod. Insert the lock pin
through the hole near the end of the hitch pin
until it snaps into its locked position. (Fig. 11)
Warning/Caution: Failure to properly install
lock pin as noted in step 7 could result in fan
loosening and possibly falling.
8. Tighten two set screws on top of the fan
motor firmly and slide the coupling cover
down.
9. Now lift the motor assembly (fan with blades)
into position and place the hanger ball into
the hanger bracket. Rotate down rod until the
"Check Tab" has dropped into the
"Registration Slot" and the down rod and ball
assembly seat firmly. The down rod and ball
assembly should not rotate if this is done
correctly. (Fig. 12)
10. An additional safety support is provided to
prevent the fan from falling. Secure the
safety cable to the ceiling joist with screw
and washer. (Fig. 12)
Supply wires
Downrod
Coupling
cover
Canopy
Canopy cover
Set screws
Hitch pin
Lock pin
Downrod
rubber cover