2m Series Userguide

Stylus guard
Remove the stylus guard before use by holding at the front and rear of the guard and
gently pressing the rear while tilting it downwards. (fig. 7-8)
Fig. 7 Fig. 8
How to replace M2.0 mm screws on 2M Verso
Remove the stylus with the stylus protection guard from the cartridge body to avoid any
damage to the diamond
Using Torx 8 key, unscrew the black screw from the Verso top plate
Remove the top plate from the cartridge body by pulling the screws off
Remove the two countersunk screws from the top plate
Insert the two M2.0 mm screws in the top plate
Mount the top plate on the cartridge body. Hold the top plate with screw-threads
hanging down and turn the cartridge body 180 degrees. Mount from above
Mount the black screw in the top plate and tighten with appropriate force
Mount the cartridge on the tonearm using the enclosed tool
Mount the stylus with the stylus protection guard on the cartridge body
12 13