2m Series Userguide
Stylus guard
Remove the stylus guard before use by holding at the front and rear of the guard and
gently pressing the rear while tilting it downwards. (fig. 7-8)
Fig. 7 Fig. 8
How to replace M2.0 mm screws on 2M Verso
• Remove the stylus with the stylus protection guard from the cartridge body to avoid any
damage to the diamond
• Using Torx 8 key, unscrew the black screw from the Verso top plate
• Remove the top plate from the cartridge body by pulling the screws off
• Remove the two countersunk screws from the top plate
• Insert the two M2.0 mm screws in the top plate
• Mount the top plate on the cartridge body. Hold the top plate with screw-threads
hanging down and turn the cartridge body 180 degrees. Mount from above
• Mount the black screw in the top plate and tighten with appropriate force
• Mount the cartridge on the tonearm using the enclosed tool
• Mount the stylus with the stylus protection guard on the cartridge body
12 13