RS232 Commands and Protocol 
Command Mode: 
Control structure to send a command is: 
<xxPPyy/ 
Reply from command is: 
 >xxPPyy/ 
< = prefix at the beginning of each action command 
Xx =  Control ID Code (see table below) 
PP =  Type of command being sent 
Yy =  Action command 
/ =  Carriage Return 
Example:  <11CH01/ sets Zone 1 to Source 1 on the Master Unit 
ID Code: 
Master 
41 
2nd Unit 
42 
3rd Unit 
43 
Zone 1 
11 
Zone 7 
21 
Zone 13 
31 
Zone 2 
12 
Zone 8 
22 
Zone 14 
32 
Zone 3 
13 
Zone 9 
23 
Zone 15 
33 
Zone 4 
14 
Zone 10 
24 
Zone 16 
34 
Zone 5 
15 
Zone 11 
25 
Zone 17 
35 
Baud Rate 9600
Data Bit 8
Stop Bit 1
Parity None