www.osram-os.com Produktdatenblatt | Version 1.1 LB P4SG LB P4SG PointLED ® With a diameter of just 2 mm, the PointLED is one of the smallest packages in its class and achieves high luminous efficacies. Due to its round and flat package, measuring only 0.775 mm high, it is ideal for application where space is a sensitive issue. Applications ——Ambient Light Sensors ——Interior Illumination e.g.
LB P4SG Ordering Information Type Luminous Intensity 1) IF = 20 mA Iv Mounting methode Ordering Code LB P4SG-S2U1-35-1 224 ... 560 mcd Reverse Q65110A8252 LB P4SG-S2U1-35-F 224 ... 560 mcd Top Q65110A8253 2 Version 1.
LB P4SG Maximum Ratings Parameter Symbol Operating Temperature Top min. max. -40 °C 100 °C Storage Temperature Tstg min. max. -40 °C 100 °C Junction Temperature Tj max. 125 °C Forward current TS = 25 °C IF min. max. 3 mA 20 mA Surge Current t ≤ 10 µs; D = 0.005 ; TS = 25 °C IFS max. 200 mA Reverse voltage 2) TS = 25 °C VR max. 5V ESD withstand voltage acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) VESD 3 Version 1.
LB P4SG Characteristics IF = 20 mA; TS = 25 °C Parameter Symbol Peak Wavelength λpeak typ. 465 nm Dominant Wavelength 3) IF = 20 mA λdom min. typ. max. 464 nm 470 nm 476 nm Spectral Bandwidth at 50% Irel,max ∆λ typ. 25 nm Viewing angle at 50 % IV 2φ typ. 120 ° Forward Voltage 4) IF = 20 mA VF min. typ. max. 2.90 V 3.20 V 3.70 V Reverse current 2) VR = 5 V IR typ. max. 0.01 µA 10 µA Temperature Coefficient of Peak Wavelength -10°C ≤ T ≤ 100°C TCλpeak typ.
LB P4SG Brightness Groups Group Luminous Intensity 1) IF = 20 mA min. Iv Luminous Intensity. 1) IF = 20 mA max. Iv Luminous Flux 6) IF = 20 mA typ. ΦV S2 224 mcd 280 mcd 760 mlm T1 280 mcd 355 mcd 950 mlm T2 355 mcd 450 mcd 1210 mlm U1 450 mcd 560 mcd 1520 mlm Forward Voltage Groups Group Forward Voltage 4) IF = 20 mA min. VF Forward Voltage 4) IF = 20 mA max. VF 4 2.90 V 3.20 V 5 3.20 V 3.50 V 6 3.50 V 3.
LB P4SG Group Name on Label Example: S2-3-4 Brightness Wavelength Forward Voltage S2 3 4 6 Version 1.
LB P4SG Relative Spectral Emission 6) Irel = f (λ); IF = 20 mA; TS = 25 °C Irel LB P4SG 1,0 : Vλ 0,8 0,6 0,4 0,2 0,0 350 400 450 500 550 600 650 700 750 800 λ [nm] Radiation Characteristics 6) Irel = f (ϕ); TS = 25 °C LB P4SG ϕ [°] -20° -40° -50° -10° 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 1,0 -30° 0,8 0,6 -60° -70° -80° -90° -100° 7 Version 1.
LB P4SG Forward current Relative Luminous Intensity 6), 7) IF = f(VF); TS = 25 °C IF [mA] 6), 7) Iv/Iv(20 mA) = f(IF); TS = 25 °C LB P4SG IV LB P4SG 20 IV(20mA) 1 0,9 0,8 0,7 0,6 10 9 0,5 8 7 0,4 6 5 0,3 4 3,3 VF [V] Dominant Wavelength 6) ∆λdom = f(IF); TS = 25 °C LB P4SG ∆λ dom [nm] 8 6 4 2 0 -2 20 18 16 14 12 8 10 6 3 -4 IF [mA] 8 Version 1.
LB P4SG Forward Voltage Relative Luminous Intensity 6) Iv/Iv(25 °C) = f(Tj); IF = 20 mA ∆VF = VF - VF(25 °C) = f(Tj); IF = 20 mA ∆VF [V] LB P4SG 0,4 6) Iv LB P4SG 1,2 Iv(25°C) 1,0 0,2 0,8 0,6 0,0 0,4 0,2 -0,2 -40 -20 0 20 40 60 80 100 Tj [°C] Dominant Wavelength 6) ∆λdom = λdom - λdom(25 °C) = f(Tj); IF = 20 mA LB P4SG ∆λ dom [nm] 6 4 2 0 -2 -4 -6 -40 -20 0 20 40 60 80 100 Tj [°C] 9 Version 1.
LB P4SG Max. Permissible Forward Current IF = f(T) IF OHL02567 25 mA TS 20 TA 15 10 5 TA temp. ambient TS temp. solder point 0 0 20 40 60 80 ˚C 100 T Permissible Pulse Handling Capability Permissible Pulse Handling Capability IF = f(tp); D: Duty cycle; TS = 25 °C IF = f(tp); D: Duty cycle; TS = 85 °C 0.25 IF A OHL02565 t tP D = TP 0.20 D= 0.15 0.10 IF T 0.20 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1 0.15 0.10 0.05 tp OHL02566 t tP D = TP IF T D= 0.005 0.01 0.02 0.
LB P4SG Dimensional Drawing 8) Approximate Weight: 6.0 mg Corrosion test: Class: 1B Test condition: 25°C / 75 % RH / 200ppb SO2, 200ppb NO2, 10ppb H2S, 10ppb Cl2 / 21 days (EN 60068-2-60 (Method 4)) 11 Version 1.
LB P4SG Recommended Solder Pad 8) For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Recommended Solder Pad 8) For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. 12 Version 1.
LB P4SG Reflow Soldering Profile Product complies to MSL Level 2 acc.
LB P4SG Taping 8) 14 Version 1.
LB P4SG Taping 8) 15 Version 1.
LB P4SG Tape and Reel 9) Reel dimensions [mm] A W Nmin W1 W2 max Pieces per PU 180 mm 8 + 0.3 / - 0.1 60 8.4 + 2 14.4 3000 16 Version 1.
LB P4SG Barcode-Product-Label (BPL) Dry Packing Process and Materials 8) Moisture-sensitive label or print Barcode label L VE LE see lab e If nk, bla cod bar hu ve y el . H) (R dit mi e ed ag % . RH /60 ˚C rar ck rel 30 N s VE RS inf pa % ainITI TO of to ak 90 d ntNSUC < ns (pe or TIO d , cte itio an bje ing U g coSEND ˚C nd 5 ˚C su ss CO Ais baRE co ± ce y 40 be TU MI CThIS ˚C < ll pro tor SE ati _ < ). urs urs Ho de urs Ho co 72 Ho urs te 48 e Ho 24 6 da e tim e th tim or ).
LB P4SG Transportation Packing and Materials 8) DE R 18 -1 -1 +Q P OU P: 44 01 C: 99 8 D/ 20 00 (9 D) 210 021 : 34 O H 12 (Q )Q TY : S S em R ic AM o nd O uc p to to H rs NO TC BA 3G 5 14 2 (6 P) NO : 12 T 11 00 LO (1 T) NO : OD M Y DE -1 18 P -1 + Q R G RO UP : (G ) 44 01 D/ C: (9 D) 0 AM 00 TY :2 )Q O SR 34 NO : (X ) PR O D 5 14 2 110 0 (Q A R ic NO : O S em S (1 T) LO T NO (6 P) : 12 3G BA TC H H 12 o M n O d u p ct to o rs M Muster
LB P4SG Type Designation System Wavelength (λdom typ.
LB P4SG Notes The evaluation of eye safety occurs according to the standard IEC 62471:2006 (photo biological safety of lamps and lamp systems). Within the risk grouping system of this IEC standard, the LED specified in this data sheet falls into the class exempt group (exposure time 10000 s). Under real circumstances (for exposure time, conditions of the eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices.
LB P4SG Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization.
LB P4SG Glossary 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ±8 % and an expanded uncertainty of ±11 % (acc. to GUM with a coverage factor of k = 3). 2) Reverse Operation: Reverse Operation of 10 hours is permissible in total. Continuous reverse operation is not allowed. 3) Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ±0.
LB P4SG Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. 23 Version 1.