www.osram-os.com Produktdatenblatt | Version 1.1 LJ CKBP LJ CKBP OSLON ® Signal The OSLON® Signal combine a compact size (small footprint: 3x3mm) with a high efficiency and a electrically insulated thermal pad.
LJ CKBP Ordering Information Type Luminous Flux 1) IF = 350 mA ΦV Ordering Code LJ CKBP-JZKZ-25-1 61 ... 112 lm Q65111A5609 LJ CKBP-JYKY-36-1 52 ... 97 lm Q65111A5610 LJ CKBP-HYKX-47-1 33 ... 82 lm Q65112A0755 2 Version 1.
LJ CKBP Maximum Ratings Parameter Symbol Operating Temperature Top min. max. -40 °C 120 °C Storage Temperature Tstg min. max. -40 °C 120 °C Junction Temperature Tj max. 150 °C Junction Temperature for short time applications* Tj max. 175 °C Forward current TS = 25 °C IF min. max. 30 mA 1000 mA Surge Current t ≤ 10 µs; D = 0.005 ; TS = 25 °C IFS max. 2000 mA ESD withstand voltage acc.
LJ CKBP Characteristics IF = 350 mA; TS = 25 °C Parameter Symbol Peak Wavelength 3) λpeak typ. 632 nm Dominant Wavelength 3) IF = 350 mA λdom min. typ. max. 612 nm 625 nm 636 nm Spectral Bandwidth at 50% Irel,max ∆λ typ. 18 nm Viewing angle at 50 % IV 2φ typ. 125 ° Forward Voltage 4) IF = 350 mA VF min. typ. max. 2.00 V 2.15 V 2.60 V Reverse voltage (ESD device) VR ESD min. 5V Reverse voltage IR = 5 mA VR max.
LJ CKBP Brightness Groups Group Luminous Flux 1) IF = 350 mA min. ΦV Luminous Flux 1) IF = 350 mA max. ΦV Luminous Intensity 6) IF = 350 mA typ. Iv HY 33 lm 39 lm 12 cd HZ 39 lm 45 lm 14 cd JX 45 lm 52 lm 16 cd JY 52 lm 61 lm 19 cd JZ 61 lm 71 lm 22 cd KX 71 lm 82 lm 25 cd KY 82 lm 97 lm 30 cd KZ 97 lm 112 lm 35 cd Forward Voltage Groups Group Forward Voltage 4) IF = 350 mA min. VF Forward Voltage 4) IF = 350 mA max. VF J3 2.00 V 2.15 V M3 2.15 V 2.
LJ CKBP Wavelength Groups Group Dominant Wavelength 3) IF = 350 mA min. λdom Dominant Wavelength 3) IF = 350 mA max. λdom 2 612 nm 616 nm 3 616 nm 620 nm 4 620 nm 624 nm 5 624 nm 628 nm 6 628 nm 632 nm 7 632 nm 636 nm 6 Version 1.
LJ CKBP Group Name on Label Example: HY-2-J3 Brightness Wavelength Forward Voltage HY 2 J3 7 Version 1.
LJ CKBP Relative Spectral Emission 6) Irel = f (λ); IF = 350 mA; TS = 25 °C Φrel LJ CKBP 1,0 : Vλ : 625 nm : 617 nm : 633 nm 0,8 0,6 0,4 0,2 0,0 350 400 450 500 550 600 650 700 750 800 λ [nm] Radiation Characteristics 6) Irel = f (ϕ); TS = 25 °C LJ CKBP ϕ [°] -20° -40° -50° -10° 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 1,0 -30° 0,8 0,6 -60° -70° -80° -90° -100° 8 Version 1.
LJ CKBP Forward current Relative Luminous Flux 6), 7) IF = f(VF); TS = 25 °C IF [mA] 6), 7) Φv/Φv(350 mA) = f(IF); TS = 25 °C LJ CKBP ΦV LJ CKBP 1000 ΦV(350mA) : 625 nm : 617 nm : 633 nm 2,5 : 625 nm : 617 nm : 633 nm 800 2,0 600 1,5 400 1,0 0,5 200 2,8 VF [V] 9 Version 1.
LJ CKBP Forward Voltage Relative Luminous Flux 6) ∆VF = VF - VF(25 °C) = f(Tj); IF = 350 mA ∆VF [V] Φv/Φv(25 °C) = f(Tj); IF = 350 mA LJ CKBP 0,3 Φv : 625 nm : 617 nm : 633 nm 0,2 6) LJ CKBP 1,6 Φv(25°C) : 625 nm : 617 nm : 633 nm 1,4 1,2 0,1 1,0 0,0 0,8 0,6 -0,1 0,4 -0,2 0,2 -0,3 -40 -20 0 20 40 60 80 100 120 Tj [°C] Dominant Wavelength 6) ∆λdom = λdom - λdom(25 °C) = f(Tj); IF = 350 mA LJ CKBP λ dom [nm] 20 : 625 nm : 617 nm : 633 nm 10 0 -10 -20 -40 -20 0 20 4
LJ CKBP Max. Permissible Forward Current IF = f(T) IF [mA] LJ CKBP 1100 1000 900 800 700 600 : TS 500 400 300 200 100 0 Do not use below 30 mA 0 20 40 60 80 100 120 T [°C] Permissible Pulse Handling Capability Permissible Pulse Handling Capability IF = f(tp); D: Duty cycle; TS = 25 °C IF = f(tp); D: Duty cycle; TS = 85 °C IF 2.1 A 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 OHL04184 t D = TP tP IF IF 2.1 A 1.9 T OHL04183 t D = TP tP IF T 1.8 D= 1.7 0.005 0.01 0.02 0.05 0.1 0.
LJ CKBP Dimensional Drawing 8) Approximate Weight: 25.0 mg Package marking: Cathode Corrosion test: Class: 3A Test condition: 40°C / 90 % RH / 15 ppm H2S / 14 days (stricter then IEC 60068-2-43) ESD advice: 12 Version 1.6 | 2018-08-23 The device is protected by ESD device which is connected in parallel to the Chip.
LJ CKBP Recommended Solder Pad 8) For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. 13 Version 1.
LJ CKBP Reflow Soldering Profile Product complies to MSL Level 2 acc.
LJ CKBP Taping 8) 15 Version 1.
LJ CKBP Tape and Reel 9) Reel dimensions [mm] A W Nmin W1 W2 max Pieces per PU 180 mm 12 + 0.3 / - 0.1 60 12.4 + 2 18.4 600 16 Version 1.
LJ CKBP Barcode-Product-Label (BPL) Dry Packing Process and Materials 8) Moisture-sensitive label or print Barcode label L VE LE see lab e If nk, bla cod bar hu ve y el . H) (R dit mi e ed ag % . RH /60 ˚C rar ck rel 30 N s VE RS inf pa % ainITI TO of to ak 90 d ntNSUC < ns (pe or TIO d , cte itio an bje ing U g coSEND ˚C nd 5 ˚C su ss CO Ais baRE co ± ce y 40 be TU MI CThIS ˚C < ll pro tor SE ati _ < ). urs urs Ho de urs Ho co 72 Ho urs te 48 e Ho 24 6 da e tim e th tim or ).
LJ CKBP Transportation Packing and Materials 8) DE R 18 -1 -1 +Q P OU P: 44 01 C: 99 8 D/ 20 00 (9 D) 210 021 : 34 O H 12 (Q )Q TY : S S em R ic AM o nd O uc p to to H rs NO TC BA 3G 5 14 2 (6 P) NO : 12 T 11 00 LO (1 T) NO : OD M Y DE -1 18 P -1 + Q R G RO UP : (G ) 44 01 D/ C: (9 D) 0 AM 00 TY :2 )Q O SR 34 NO : (X ) PR O D 5 14 2 110 0 (Q A R ic NO : O S em S (1 T) LO T NO (6 P) : 12 3G BA TC H H 12 o M n O d u p ct to o rs M Muster
LJ CKBP Type Designation System Wavelength (λdom typ.
LJ CKBP Notes The evaluation of eye safety occurs according to the standard IEC 62471:2006 (photo biological safety of lamps and lamp systems). Within the risk grouping system of this IEC standard, the device specified in this data sheet falls into the class exempt group (exposure time 10000 s). Under real circumstances (for exposure time, conditions of the eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices.
LJ CKBP Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization.
LJ CKBP Glossary 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ±8 % and an expanded uncertainty of ±11 % (acc. to GUM with a coverage factor of k = 3). 2) Reverse Operation: Reverse Operation of 10 hours is permissible in total. Continuous reverse operation is not allowed. 3) Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ±0.
LJ CKBP Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. 23 Version 1.