Datasheet
SFH 3710
3
Version 1.4 | 2018-11-26
Characteristics
T
A
= 25 °C
Parameter Symbol Values
Wavelength of max sensitivity λ
S max
typ. 570 nm
Spectral range of sensitivity λ
10%
typ. 350 ... 950 nm
Dimensions of chip area L x W typ. 0.75 x 0.75
mm x mm
Radiant sensitive area A typ. 0.29 mm²
Half angle φ typ. 60 °
Photocurrent
V
CE
= 5 V; Std. Light A; E
v
= 1000 lx
I
PCE
typ. 350 µA
Dark current
V
CE
= 5 V; E = 0
I
CE0
typ.
max.
3 nA
50 nA
Collector-emitter saturation voltage
1)
I
C
= I
PCE,min
X 0.3; E
e
= 0.01 mW/cm²
V
CEsat
typ. 100 mV
Capacitance
V
CE
= 0 V; f = 1 MHz; E = 0
C
CE
typ. 4 pF
Temperature coecient of sensitivity
λ = 550 nm
TC
I
typ. 0.78 % / K
Temperature coecient of sensitivity
Std. Light A
TC
I
typ. 0.9 % / K