www.sylvania.com Note: OSRAM SYLVANIA LTD.
8THS OSRAM SYLVANIA SEE THE WORLD IN A NEW LIGHT For more than 100 years, OSRAM SYLVANIA has been a leader in the development of innovative lighting. This catalog provides specifications on over 3000 SYLVANIA and OSRAM branded products for a variety of lighting applications, each one designed and manufactured to the highest possible standards. A Lighting Industry Leader With over 14,000 employees, OSRAM SYLVANIA is one of the leading lighting systems companies in North America.
8THS OSRAM SYLVANIA SEE THE WORLD IN A NEW LIGHT For more than 100 years, OSRAM SYLVANIA has been a leader in the development of innovative lighting. This catalog provides specifications on over 3000 SYLVANIA and OSRAM branded products for a variety of lighting applications, each one designed and manufactured to the highest possible standards. A Lighting Industry Leader With over 14,000 employees, OSRAM SYLVANIA is one of the leading lighting systems companies in North America.
Table of Contents Sustainability III SYLVANIA ECOLOGIC® IV Lamp Recycling Energy and the Cost of Lighting IESNA Progress Report Glossary of Terms Incandescent Lamps V VI VII IX–XII 1 Tungsten Halogen Lamps 41 Miniature Lamps 72 High Intensity Discharge (HID) Lamps 75 Compact Fluorescent Lamps 107 Fluorescent Lamps 129 Ballasts and LED Power Supplies 171 Display/Optic Lamps 207 LED Systems 297 Consumer Luminaires 314 LED Retrofit Lamps 315 Warranties 316 Index 322 Important Noti
Luminance Contrast The relationship between PAR Lamps Pressed aluminized reflector lamp, Safety Ballasts should be installed and operated the luminances of an object and its immediate background. with the outer bulb formed from two pressed glass parts that are fused or sealed together. PAR lamps may be incandescent, halogen, or HID types. in compliance with the National Electric Code (NEC), Underwriters Laboratories Inc. (UL) requirements, and all applicable codes and regulations.
Sustainability in Action Meeting our needs today without compromising the resources future generations will need — touches everything we do as a company. It’s all about reducing environmental impact, a commitment that goes beyond our products to include how the products are manufactured, how they are used and how they are distributed and disposed. It even extends to the design of “greener” buildings. Sustainability is everybody’s business. Global Care: When we can do more with less, everyone wins.
ECOLOGIC® products are the industry’s most comprehensive line of environmentally preferable lighting solutions. Our lamps designated as ECOLOGIC pass the U.S. EPA’s Toxic Characteristic Leaching Procedure (TCLP) test for hazardous waste determination. Products meeting the TCLP test may be declared “universal waste” in many states, easing the administrative, storage and transportation burdens for these products. (Check your state and local governments for the most accurate regulations.
THIS PROGRAM IS CURRENTLY AVAILABLE ONLY IN THE U.S.A.
Energy and the Cost of Lighting According to the U.S. Department of Energy, we consume about one-quarter of our electricity for lighting, at a cost of more than $37 billion annually. Lighting accounts for the single largest portion of electric bills for commercial users, as much as 30% — and it can be a prime opportunity for reducing energy costs. Saving energy, saving money Energy costs represent your biggest and best opportunity for savings.
SYLVANIA Products and the IESNA Progress Report A Proud Legacy of Achievement Each year, The Progress Committee of the Illuminating Engineering Society of North America (IESNA) solicits the lighting industry for product submissions which, if accepted by the committee, are featured in the committee’s Progress Report, which is published in the IESNA’s publication “Lighting Design & Application”.
2006 Progress Report OSRAM SYLVANIA submissions accepted by the IESNA Progress Report Significance to the Lighting Industry 20W METALARC® POWERBALL® Ceramic Metal Halide PAR 30 Lamp Highest lamp life for 20W PAR 30 CMH. 39W METALARC POWERBALL Ceramic Metal Halide PAR 20 or PAR 30 Lamp Highest CRI PAR 20 or PAR30 CMH – 5% improvement. 750W SUPER METALARC® Pulse Start First base down 750w MH Pulse Start lamp. ® 54W PENTRON HO Primary Colors T5 Fluorescent Lamps First T5 HO single phosphor lamps.
Product Catalog Glossary of Terms Ampere A unit expressing the rate of flow of electric current. Ballast Fusing (See Fusing.) ANSI (American National Standards Institute) The organization that develops designed to have an average life expectancy of 60,000 hours. To maximize life, ambient temperature should be kept as low as possible. It is also important to maintain effective dissipation of heat using the lighting fixture as a heatsink for the ballast enclosure.
Energy A measure of work done by an electrical system over a given period of time, often expressed in kilowatt-hours (kWh). Hertz (Hz) A unit of frequency equal to one cycle per second; see frequency. Filament A tungsten wire purposely positioned Lamps in which an arc passing between two electrodes in a pressurized tube causes various metallic additives to vaporize and release large amounts of light. All HID lamps offer outstanding energy efficiency and service life.
010_INC_drop.qxd 12/4/07 8:19 AM Page 1 I N C A N D E S C E N T INCANDESCENT LIGHTING The incandescent lamp consists of a wire filament on a suitable mount enclosed in a glass bulb containing a gas or a vacuum. When the lamp is connected to an electrical circuit, the current passing through the wire must overcome the filament’s resistance, and the power consumed heats the filament to incandescence (causes it to glow).
010_INC_drop.qxd 12/4/07 8:19 AM Page 2 LAMP CATEGORIES I N C A N D E S C E N T SYLVANIA offers a wide assortment of premium lighting products that add value through superior performance, long life, beautiful light and rugged durability.
010_INC_drop.qxd 12/4/07 8:19 AM Page 3 BULB IDENTIFICATION I N C A N D E S C E N T Bulb size - Max. Diameter (Divide by 8) Light Center Length (L.C.L.) is the distance from the center of the light source to the following point for the base used: Screw bases...bottom base contact; Bayonet candelabra and medium bayonet...top of base pins. A-21 - 21⁄8 = 2 5⁄8” Dia. G-40 - 40⁄8 = 5” Dia. T-12 - 12⁄8 = 1 1⁄2” Dia. PS-30 - 30⁄8 = 3 3⁄4” Dia. BASE IDENTIFICATION Typical bases are shown.
010_INC_drop.qxd 12/4/07 8:19 AM Page 4 INCANDESCENT LAMP SHAPES I N C A N D E S C E N T A bulb designation consists of a letter(s) to indicate the shape and a figure(s) to indicate the approximate major diameter in eighths of in inch. For example, an F-15 bulb is a flame-shape, 15/8 of an inch or 1-7/8 inches in diameter. B10 Blunt Tip B10 Crystal B10 Cand B13 Cand F15 Med C7 Cand LINESTRA 2-base T6 Cand T6.5 Inter T6.
010_INC_drop.qxd 12/4/07 8:19 AM Page 5 HOW TO READ PRODUCT INFORMATION - INCANDESCENT 34 Watts Bulb Base Product Symbols & Number Footnotes Ordering Abbreviation Pkg Volts Qty Class & Filament Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) I N C A N D E S C E N T | | | Bulb Describes the shape of the envelope followed by the lamp’s major diameter given in eighths of an inch. See page 4: Incandescent Lamps. Base See page 3: Base Identification.
010_INC_drop.qxd 12/4/07 8:19 AM Page 6 NOTES: I N C A N D E S C E N T For more complete product information visit www.sylvania.
010_INC_F.qxd 11/29/07 7:57 AM A17 Page 7 G16.5 A21 A15 A19 B10 G25 R20 BR30, BR40 ELOGIC™ LAMPS Small Bulb. Big Difference 34 Watts Bulb Base Product Symbols & Number Footnotes Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) 38 A17 Med 10825 38A17/W/ELOGIC/4/48/RP 120 48 Soft White C, CC-8 2250 410 2.88 3.75 57 A17 Med 11721 57A17/W/ELOGIC/4/48/RP 120 48 Soft White C, CC-8 1500 740 2.88 3.
010_INC_F.qxd 11/29/07 A19 7:57 AM BR40 Page 8 C7 Candelabra B10 G25 A21 A15 DAYLIGHT® LAMPS White & Natural I N C A N D E S C E N T 34 Watts Bulb Base 75 Med A19 BR40 Med Product Symbols & Number Footnotes Ordering Abbreviation Pkg Volts Qty 11102 75A/DAY/RP/2/24 A19 Med Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 120 24 Daylight C, CC-8 750 850 3.13 4.44 10776 102,136 75A/DAY/RP/4/48 130 48 @ 120 _volts, approximate 66 watts, 650 lumens, 1875 hours.
010_INC_F.qxd 11/29/07 7:57 AM A15 Page 9 A19 B10 B13 G25 R20 A21 DOUBLE LIFE LAMPS Lasts 2X longer than ordinary Soft White lamps 34 Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes Ordering Abbreviation Pkg Volts Qty 40 Med 10046 40A15/CL/DL/FAN 120 24 Clear Double Life Fan Light C, C-9 2000 350 2.38 3.50 10133 40A15/CL/DL/BL 120 12 Clear Double Life Appliance C, C-9 2000 350 2.38 3.
010_INC_F.qxd 11/29/07 A15 7:57 AM A19 Page 10 B10 B13 G25 BR30, BR40 DOUBLE LIFE LAMPS Lasts 2X longer than ordinary Soft White lamps I N C A N D E S C E N T 34 Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 60 Med 10024 60A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life Fan Light C, C-9 2000 530 2.38 3.50 10048 60A15/CL/DL/FAN/RP 120 24 Clear Double Life Fan Light C, C-9 2000 530 2.38 3.
010_INC_F.qxd 11/29/07 A19 7:57 AM Page 11 BR40 S6 C7 Candelabra S14 S11 DOUBLE LIFE LAMPS Lasts 2X longer than ordinary Soft White lamps 34 Watts Bulb Base 100 Med A19 Product Symbols & Number Footnotes Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) 11332 100A/DL/SW/4PK/RP 120 48 Soft White Double Life C, CC-8 1500 1530 3.13 4.44 100A/DL/SW/PLUS/2PK/RP 120 24 Soft White Double Life C, CC-8 1500 1560 3.
010_INC_F.qxd 11/29/07 S11 7:57 AM Page 12 C7 Candelabra S6 S14 A15 A21 T6 T7 T10 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 120 120 Ceramic Red B, C-9 1400 2.25 10C7/CL 120 240 Clear Pilot Light Vibration Resistant B, C-7A 10S6 120 240 Clear Indicator B, C-7A 1500 71 1.44 1.88 10S6230V 230 240 Clear Indicator B, CC-7A 1500 65 1.44 1.
010_INC_F.qxd 11/29/07 7:57 AM T6.5 Page 13 A19 R14 Inter R14 T8 T10 GENERAL PURPOSE LAMPS 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 10000 5.56 Watts Bulb Base 20 T6.5 DC Bayonet 18144 1 20T6.5DC/IF 120 60 Inside Frost Exit Lamp B, C-8 Intermediate 18143 1 20T6.5/IF 120 60 Inside Frost Exit Lamp B, C-8 10000 92 25 A19 Med 11090 25A/RS 120 120 Inside Frost Rough Service B, C-17 1000 210 2.50 3.
010_INC_F.qxd 11/29/07 T10 7:57 AM Page 14 A15 A21 R20 S11 A19 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 25 Med 18491 25T10/CL/BL/6PK 120 6 Clear B, C-8 1000 232 5.63 18512 25T10 130 60 Clear B, C-8 1000 232 5.63 18503 25T10/IF 120 60 Inside Frost B, C-8 1000 230 5.63 18492 25T10/IF/BL/6PK 120 6 Inside Frost B, C-8 1000 230 5.
010_INC_F.qxd 11/29/07 7:57 AM A15 Page 15 A19 K19 R14 Inter GENERAL PURPOSE LAMPS 34 Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 40 Med 10023 40A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life Ceiling Fan Light C, C-9 2000 350 2.38 3.50 10046 40A15/CL/DL/FAN 120 24 Clear Double Life Fan Light C, C-9 2000 350 2.38 3.50 10034 40A15/CL/DL/FAN/2/12/BL 120 12 Clear Double Life Fan Light C, C-9 2000 350 2.38 3.
010_INC_F.qxd 11/29/07 R14 7:57 AM R16 Page 16 S11 T6.5 T8 T10 A21 BR30 R20 A19 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 2.25 Watts Bulb Base 40 R14 Med 14819 40R14/RP 120 6 Reflector Mini Flood C, C-9 1500 R16 Med 14821 40R16/FL/RP 120 6 Reflector Mini Flood C, C-9 1500 S11 Intermediate 13595 40S11N 120 120 Clear Hi Intensity C, C-7A 500 440 1.63 2.
010_INC_F.qxd 11/29/07 7:57 AM A19 Page 17 A21 ER30 R20 GENERAL PURPOSE LAMPS 34 Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 250 120 Inside Frost B, CC-7A 1000 490 2.50 4.44 50A 277 120 Inside Frost B, CC-7A 1000 475 2.50 4.44 50A/RS/SL 120 120 Safeline Rough Service C, C-9 1000 490 2.50 3.94 50A19/RS 75 Inside Frost Rough Service Train C, C-9 1000 505 2.50 3.
010_INC_F.qxd 11/29/07 R20 7:57 AM Page 18 A19 A15 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Watts Bulb Base Product Symbols & Number Footnotes Ordering Abbreviation 50 Med 14833 R20 2,46,68,107, Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 120 6 Reflector Flood C, C-9 2000 330lm 550 cd 45˚ 3.94 130 60 Reflector Flood C, C-9 2000 330lm 550 cd 45˚ 3.94 Reflector Flood C, C-9 2000 330lm 550 cd 45˚ 3.
010_INC_F.qxd 11/29/07 7:57 AM A15 Page 19 A19 GENERAL PURPOSE LAMPS 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 60 Med 11007 60A15/CL/FAN/RP 120 24 Clear Ceiling Fan Light C, C-9 1000 700 2.38 3.50 10884 60A15CL/FAN/2/12/BL 120 12 Clear Ceiling Fan Light C, C-9 1000 700 2.38 3.50 10886 60A15/GARAGE/2/12/BL 120 12 Clear Garage Light C, C-9 1000 690 2.38 3.
010_INC_F.qxd 11/29/07 C15 7:57 AM K19 Page 20 T10 BR30 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 60 C15 Med Brass 14200 60C15/FAN/2PK 120 12 Clear Ceiling Fan Light C, C-9 4000 528 4.50 K19 Med 10483 60K19/DR 120 24 Inside Frost Directional Reflector C, CC-6 1150 630 4.
010_INC_F.qxd 11/29/07 7:57 AM BR30, BR40 Page 21 PAR38 A19 GENERAL PURPOSE LAMPS 34 Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Double Life Reflector Flood C, CC-6 4000 510lm 300 cd 60˚ 5.38 120 24 Reflector Flood C, CC-6 2000 580lm 390 cd 60˚ 6.50 65BR/FL/RP 120 6 Reflector Flood C, CC-6 2000 580lm 390 cd 60˚ 6.50 65BR/CVP 130 6 Reflector Flood C, CC-6 2000 540lm 390 cd 60˚ 6.
010_INC_F.qxd 11/29/07 A19 7:57 AM Page 22 A21 BR38 BR40 ER30 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 750 4.44 Watts Bulb Base 75 Med 10970 75A/W/4/RP 120 48 Soft White C, CC-8 10967 75A/W/RP 120 24 Soft White C, CC-8 750 1170 3.13 4.44 12500 75A/CL 120 120 Clear C, CC-8 750 1200 3.13 4.
010_INC_F.qxd 11/29/07 K19 7:58 AM Page 23 PAR38 Side Prong R20 A19 GENERAL PURPOSE LAMPS 34 Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 75 Med 12583 75K19/DR 120 24 Inside Frost Directional Reflector C, CC-6 1150 855lm 4.13 PAR38 Med Side Prong 13850 75PAR/3FL 120 12 Compact Flood C, CC-6 2000 1040lm 1800 cd 30˚ 4.31 R20 Med 14840 75R20/RP 120 6 Reflector Flood C, CC-9 2000 500lm 500 cd 45˚ 3.
010_INC_F.qxd 11/29/07 A19 7:58 AM Page 24 A21 A23 BR38 BR40 K19 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Watts Bulb Base 100 Med A19 Med Brass Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 12709 136,193 100A/CVP 130 24 @ 120 _volts, approximate 88 watts, 1290 lumens, 1875 hours Standard Frost C, CC-8 750 1700 3.13 4.44 12530 100A/LHT 120 120 Standard Frost Left Hand Thread C, CC-8 750 1710 3.13 4.
010_INC_F.qxd 11/29/07 7:58 AM PAR38 Page 25 PS25 A23 BR40 ER40 A19 A21 GENERAL PURPOSE LAMPS 34 Watts Bulb Base Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) Hard Glass PAR Heat Lamp with Red Lens C 5000 120 12 Inside Frost 3-way 100/300W C, CC-8 1200 1385lm 3540lm 4925lm 4.25 6.75 K105A23/CL 125 24 Clear Krypton Filled ST Ltg C, C-9 12000 1120 4.38 6.06 120BR40/FL/SL 130 24 RHINOCOAT Safeline Flood C, CC-6 2000 1150lm 1000 cd 60˚ 6.
010_INC_F.qxd 11/29/07 A21 7:58 AM A23 Page 26 BR38 PAR38 PAR38 Side Prong PAR46 PS25 T10 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Description Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) C, CC-8 750 5.31 Watts Bulb Base 150 Med 13101 150A21/W/RP 120 12 Soft White 13125 150A21/CL/RP 120 12 A21 Med Brass A23 Med Pkg Volts Qty Class & Filament Product Symbols & Number Footnotes Ordering Abbreviation 2640 3.
010_INC_F.qxd 11/29/07 7:58 AM A21 Page 27 A23 PAR46 PAR56 PS25 PS30 BR38 BR40 GENERAL PURPOSE LAMPS 34 Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Watts Bulb Base 200 Med 13107 200A21 120 24 Soft White Recessed Ceiling C, CC-8 750 3650 3.88 5.31 15476 200A21/CL/RP 120 12 Clear Utility Light C, CC-8 750 3880 3.88 5.31 15491 21,136 200A21/CL 130 48 @ 120 _volts, approximate 176 watts, 2860 lumens, 1875 hours Clear C, CC-8 750 3880 3.88 5.
010_INC_F.qxd 11/29/07 R40 7:58 AM Page 28 BR40 PAR56 PS30 PS35 GENERAL PURPOSE LAMPS I N C A N D E S C E N T 34 Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) Red Bowl IR Heat Lamp Reflector Hard Glass C, C-6 5000 6.88 120 24 Reflector Flood C, CC-2V 2000 3030lm 2900 cd 60˚ 6.
010_INC_F.qxd 11/29/07 7:58 AM PAR64 Page 29 PS35 CA8, CA10, CA5 B10 F10 G16.5 GENERAL PURPOSE LAMPS 34 Watts Bulb 500 Base PAR64 Ext Mog End Pr PS35 Mogul Description Class & Filament Avg Lumens Rated Beam Angle LCL Life(hrs) CBCP (in) MOL (in) 120 6 Narrow Spot C, CC-13 2000 6500lm 110000 cd 7x12 VH 6.00 500PAR64/MFL 120 6 Med Flood C, CC-13 2000 6500lm 37000 cd 11x25 VH 6.00 500PAR64/WFL 120 6 Wide Flood C, CC-13 2000 6500lm 13000 cd 20x40 VH 6.
010_INC_F.qxd 11/29/07 B10 7:58 AM C11 Page 30 F15 G16.5 G25 G40 DECORATIVE LAMPS I N C A N D E S C E N T 1 Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Rated Life(hrs) MOL (in) 25B10C/F/BL/2PK 120 12 Frosted Décor Bent Tip C, C-7A 1500 3.88 Watts Bulb Base Product Symbols & Number Footnotes 25 Candelabra 13453 Med 13331 94 25B10/DL/BL/4PK 120 24 Clear Double Life Décor Bent Tip C, C-7A 3000 3.
010_INC_F.qxd 11/29/07 7:58 AM B10 Page 31 B13 C15 F15 G16.5 DECORATIVE LAMPS 1 Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Rated Life(hrs) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 40 Candelabra 13571 40B10C/BAGPK 120 200 Clear Décor Bent Tip C, C-7A 1500 3.88 13648 40B10C/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 3.88 13456 40B10C/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 3.
010_INC_F.qxd 11/29/07 G16.5 7:58 AM G25 Page 32 G30 G40 A19 B10 DECORATIVE LAMPS I N C A N D E S C E N T 1 Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Rated Life(hrs) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 40 Candelabra 13666 40G16.5C/BL 120 12 Clear Globe C, C-7A 1500 3.00 13667 40G16.5C/W/BL 120 12 White Globe C, C-7A 1500 3.00 10352 40G16.5/4PK/BL 120 24 Clear Globe C, C-7A 1500 3.00 10300 40G16.
010_INC_F.qxd 11/29/07 7:58 AM B10 Page 33 B13 C15 F15 G16.5 G25 G30 G40 A21 P25 DECORATIVE LAMPS 1 Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Rated Life(hrs) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 60 Med 13650 60B10/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 3.81 13442 60B10/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 3.81 13721 60B10/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 3.
010_INC_F.qxd 11/29/07 PS25 7:58 AM Page 34 PS35 A19 A21 A23 DECORATIVE LAMPS I N C A N D E S C E N T 1 Ordering Abbreviation Pkg Volts Qty Description Class & Filament Avg Rated Life(hrs) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 150 PS25 Med 15271 150PS25/SB 120 60 Silver Bowl C, C-9 1000 6.94 300 PS35 Mogul 15958 300PS35/SB/IF 120 24 Silver Bowl Inside Frost Brass Base C, C-9 1000 9.
010_INCsf.qxd 11/29/07 8:08 AM Page 35 SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS Symbol Description I N C A N D E S C E N T New item introduced within the past year. Item will be discontinued when inventory is depleted. Indicates aluminum base. Do not operate in household sockets. Operate base down. Operate base down to horizontal. Heat resistant, hard glass. PAR lamps are suitable for indoor and outdoor use. Do not operate in paper lined sockets.
010_INCsf.qxd 11/29/07 8:08 AM Page 36 SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS I N C A N D E S C E N T Footnote Description 28 @ 120 volts, approximate 264 watts, 3850 lumens, 6250 hours 29 @ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours 30 @ 120 volts, approximate 264 watts, 4305 lumens, 1875 hours 31 Additional product information can be found in the SYLVANIA Automotive, Miniature and Sealed Beam Lamp Catalog Form 208.
010_INCsf.qxd 11/29/07 8:08 AM Page 37 SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS Footnote Description 71 Even though this bulb may continue to light after the lens or reflector is cracked or broken, it should be replaced as soon as possible since the pressure filled inner capsule could unexpectedly shatter, creating a risk of personal injury or property damage.
010_INCsf.qxd 11/29/07 8:08 AM Page 38 SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS I N C A N D E S C E N T Footnote Description 114 Use only in fixtures designed to adequately dissipate heat from lamp. 115 3" Circular window. 116 Operation of lamp in any position other than base up may result in some loss of protective coating. 117 A protective shield must be used external to the lamp. 118 In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
010_INCsf.
100_cref.qxd 11/29/07 8:11 AM Page 40 Manufacturers’ Cross Reference Guide (continued) I N C A N D E S C E N T INCANDESCENT LAMPS INCANDESCENT LAMPS SYLVANIA GE PHILIPS SYLVANIA GE PHILIPS 4C7/BL/2PK 4C7/W/BL/2PK 10C7/CL 10S11N/CL 15B10/BL/2PK 15B10C/DL/BL 15S14/CL 130V 20T6.5DC/IF 25B10C/DL/BL 25B10/DL/BL 25G16.
020_TH_drop.qxd 12/17/07 8:17 AM Page 41 OSRAM SYLVANIA: THE LEADER IN HALOGEN LAMP TECHNOLOGY T U N G S T E N H A L O G E N Halogen lamps are generally of the 'lamp within a lamp' design. The outer 'lamp' or jacket is made from a heavy walled borosilicate glass. The inner 'lamp' is the tungsten halogen capsule that is made from either glass or quartz and contains a filament, lead wires and a halogen gas mixture. CAPSYLITE IR® Save energy while still making your merchandise stand out from the crowd.
020_TH_drop.qxd 12/3/07 9:55 AM Page 42 FILAMENTS T U N G S T E N H A L O G E N CC-8 CC-2V CC-6 Axial (AX) Tranverse (TR) C-8 Double End BASES Ext. Mog. End Prong E10 Miniature Screw E11 Mini can G4 E26 Medium Skt. G9 E26 Medium G53 Recessed Single Contact RSC R7s GY 6.35 Screw Term. GU4 DC Bayonet B15d BA15d GU5.3 Mogul End Prong GU10 Med Side Pr. LAMPS BT4 BT4T3, T4 BI-PIN PAR30 PAR56 Mog End Pr T4 G9. PAR14 PAR38 PAR16 PAR30LN PAR36 Medium Skt.
020_TH_drop.
020_TH_drop.
020_TH_print.qxd 12/17/07 8:13 AM Page 45 A19 CAPSYLITE® A-LINE Suitable for use in unshielded fixtures. 15 Watts Bulb Base Product Symbols & Number Footnotes 42 E26 Med 18907 A19 18908 137,154 Ordering Abbreviation Pkg Lamp Volts Qty Finish Avg Class & Rated Lumens LCL Filament Life(hrs) CCT (in) MOL (in) 42A/HAL/F 120 12 Inside Frost C,CC-8 3500 580 2750 3.13 4.38 42A/HAL/F 130 12 Inside Frost C,CC-8 3500 580 2750 3.13 4.
020_TH_F_print.qxd 12/3/07 BT15 9:56 AM B11 Page 46 G25 F17 T10 HALOGEN BT15 Suitable for use in unshielded fixtures. 15 T U N G S T E N H A L O G E N Ordering Abbreviation Pkg Lamp Volts Qty Finish Avg Class & Rated Lumens LCL Filament Life(hrs) CCT (in) MOL (in) 73,74,84, 60BT15/HAL/CL/BL 120 10 Clear C,CC-8 3000 820 2900 2.94 4.63 72,73,74, 60BT15/HAL/W/BL 120 10 White C,CC-8 3000 760 2900 2.94 4.63 75BT15/HAL/W/BL 120 10 White C,CC-8 3000 1010 2900 2.94 4.
020_TH_F_print.qxd 12/3/07 PAR20 9:56 AM Page 47 PAR30LN PAR38 PAR14 PAR16 GU10 DAYLIGHT PLUS® PAR LAMPS Suitable for use in unshielded fixtures. 16 Watts Bulb Base Product Symbols & Number Footnotes 50 E26 Med 15226 PAR20 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50PAR20/HAL/DAY/NFL 120 6 NFL C,CC-8 2500 500 2900 1000 30 3.25 50PAR30LN/HAL/DAY/WFL 120 6 WFL C,CC-8 2500 550 2900 550 50 4.
020_TH_F_print.qxd PAR16 GU10 12/3/07 9:56 AM PAR16 GU10 Page 48 PAR20 CAPSYLITE® PAR16 LAMPS Suitable for use in unshielded fixtures. 16 T U N G S T E N H A L O G E N Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) Watts Bulb Base Product Symbols & Number Footnotes 50 GU10 59061 72 50PAR16/HAL/GU10/FL/BL3 120 18 FL C,CC-8 3000 450 2800 800 30 2.
020_TH_F_print.qxd 12/3/07 PAR20 9:56 AM Page 49 PAR30 CAPSYLITE® PAR20 Suitable for use in unshielded fixtures. 16 Watts Bulb Base Product Symbols & Number Footnotes 35 E26 Med 14467 PAR20 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 35PAR20/HAL/NSP10 120 15 NSP C,CC-8 2500 360 2775 3000 10 3.25 35PAR20/HAL/NFL30 120 15 NFL C,CC-8 2500 360 2775 800 30 3.
020_TH_F_print.qxd 12/3/07 PAR30 9:56 AM Page 50 PAR30LN CAPSYLITE® PAR30 Suitable for use in unshielded fixtures. 16 T U N G S T E N H A L O G E N Watts Bulb Base Product Symbols & Number Footnotes 50 E26 Med 14526 PAR30 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50PAR30/HAL/NSP9 120 15 NSP C,CC-8 2500 660 2850 8800 9 3.63 50PAR30/HAL/NSP9 130 15 NSP C,CC-8 2500 660 2850 8800 9 3.
020_TH_F_print.qxd 12/3/07 9:56 AM PAR30LN Page 51 PAR38 CAPSYLITE® PAR30 LONG NECK Suitable for use in unshielded fixtures. 16 Watts Bulb Base Product Symbols & Number Footnotes 50 E26 Med 14482 PAR30LN Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50PAR30LN/HAL/NSP9 130 15 NSP C,CC-8 2500 660 2850 7000 10 4.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 52 PAR38 CAPSYLITE IR® PAR38 Halogen PAR lamp with infrared reflective coating on the lamp capsule. Suitable for use in unshielded fixtures. 16 T U N G S T E N H A L O G E N Watts Bulb Base Product Symbols & Number Footnotes 50 E26 Med Skt 14136 PAR38 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50PAR38/CAPIR/SP9 120 15 SP C,CC-8 3000 850 2825 14000 9 5.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 53 PAR38 CAPSYLITE® PAR38 Suitable for use in unshielded fixtures. 16 Watts Bulb Base Product Symbols & Number Footnotes 45 E26 Med Skt 14588 PAR38 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 45PAR38/HAL/FL30 120 15 FL C,CC-8 2500 560 2825 1500 30 5.31 45PAR38/HAL/FL 120 6 FL C,CC-8 2500 560 2825 1500 30 5.
020_TH_F_print.qxd PAR38 12/3/07 9:56 AM Page 54 PAR38 Med Side Prong CAPSYLITE® PAR38 Suitable for use in unshielded fixtures. 16 T U N G S T E N H A L O G E N Watts Bulb Base Product Symbols & Number Footnotes 75 E26 Med Skt 14517 PAR38 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 75PAR38/HAL/WFL50 130 15 WFL C,CC-8 2500 1060 2900 1300 50 5.
020_TH_F_print.qxd 12/3/07 PAR38 9:56 AM Page 55 PAR56 PAR64 CAPSYLITE® PAR38 Suitable for use in unshielded fixtures. 16 Watts Bulb Base Product Symbols & Number Footnotes 120 E26 Med Skt 14576 PAR38 Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 120PAR38/HAL/FL 120 6 FL C,CC-8 3000 1800 2950 4600 30 5.31 120PAR38/HAL/FL30 130 15 FL C,CC-8 3000 1800 2950 4600 30 5.
020_TH_F_print.qxd T4 12/3/07 9:56 AM T3, T4 Page 56 T4 CAPSYLITE® G9 LAMPS Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements. T U N G S T E N H A L O G E N 15 Ordering Abbreviation Pkg Lamp Volts Qty Finish Avg Class & Rated Lumens LCL Filament Life(hrs) CCT (in) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 25 G9 Bipin 57020 72,84,145 25T4/G9/CL 120 20 Clear C,CC-2V 2000 255 2900 0.
020_TH_F_print.qxd 12/3/07 T4 9:56 AM Page 57 T4 T3 SUPERQ SINGLE END HALOGEN LAMPS A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from possible ultraviolet radiation.
020_TH_F_print.qxd 12/3/07 T3 9:56 AM Page 58 T3 BT4 BT4 DOUBLE END QUARTZ LAMPS A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from possible ultraviolet radiation.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 59 T3, T4 STARLITE BI-PIN LAMPS Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements. 15 Ordering Abbreviation Pkg Lamp Volts Qty Finish Avg Class & Rated Lumens LCL Filament Life(hrs) CCT (in) MOL (in) Watts Bulb Base Product Symbols & Number Footnotes 10 G4 Bipin 58692 142,145 10T3Q/CL/AX 6 40 Clear C,AXIAL 4000 130 3000 0.88 1.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 60 MR16 TRU-AIM IR® MR16 LAMPS UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the lamp capsule. T U N G S T E N H A L O G E N 16 Watts Bulb Base Product Symbols & Number Footnotes 20 GU5.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 61 MR16 TRU-AIM TITAN® MR16 LAMPS UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector. 16 Watts Bulb Base Product Symbols & Number Footnotes 50 GU5.3 Bipin 58310 MR16 62,65,91, Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50MR16/T/WFL60/C(FNV) 12 C, AXIAL 4000 1100 60 1.75 2650 25 1.75 13300 10 1.75 3800 25 1.
020_TH_F_print.qxd 12/3/07 9:56 AM MR16, MR11, MR16 SIG 64005 Page 62 PAR36 TRU-AIM® MR16 LAMPS UV Filter capsule with axial filament in covered dichroic reflector. 16 T U N G S T E N H A L O G E N Watts Bulb Base Product Symbols & Number Footnotes 50 GU5.3 Bipin 58326 MR16 45,62,92, Ordering Abbreviation Pkg Beam Volts Qty Type Avg Class & Rated Lumens Filament Life(hrs) CCT CBCP Beam MOL Angle (in) 50MR16/NFL25/C(EXZ) 12 C, AXIAL 2000 2800 25 1.75 1450 35 1.75 690 60 1.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 63 AR70, AR111 AR70 ALUMINUM REFLECTOR LAMPS UV Filter capsule with axial filament in precisely engineered aluminum reflector. Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 64 SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS Symbol Description New item introduced within the past year. T U N G S T E N H A L O G E N Item will be discontinued when inventory is depleted. Indicates aluminum base. Do not operate in household sockets. Operate base down. Operate base down to horizontal. Heat resistant, hard glass. PAR lamps are suitable for indoor and outdoor use. Do not operate in paper lined sockets.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 65 SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS Footnote Description 28 @ 120 volts, approximate 264 watts, 3850 lumens, 6250 hours 29 @ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours 30 @ 120 volts, approximate 264 watts, 4305 lumens, 1875 hours 31 Additional product information can be found in the SYLVANIA Automotive, Miniature and Sealed Beam Lamp Catalog Form 208. 32 UV Filter capsule with axial filament in dichroic reflector.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 66 SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS T U N G S T E N H A L O G E N Footnote Description 71 Even though this bulb may continue to light after the lens or reflector is cracked or broken, it should be replaced as soon as possible since the pressure filled inner capsule could unexpectedly shatter, creating a risk of personal injury or property damage.
020_TH_F_print.qxd 12/3/07 9:56 AM Page 67 SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS Footnote Description 114 Use only in fixtures designed to adequately dissipate heat from lamp. 115 3" Circular window. 116 Operation of lamp in any position other than base up may result in some loss of protective coating. 117 A protective shield must be used external to the lamp. 118 In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
020_TH_F_print.
100_cref.
100_cref.
100_cref.
030_MIN_F_print.
030_MIN_F_print.qxd 12/12/07 3:12 PM Page 73 MINIATURE & AUTOMOTIVE LAMPS Ordering Abbreviation 17 Product Number Bulb Base Avg Rated Life (hrs) Approx Lumens Amps Design Pkg Voltage (V) Qty MOL (in) 330 334 3797 24V2W 382 385 387 388 44 35183 35205 39375 35311 35321 35327 35349 33459 T1.75 T1.75 T2.75 T1.75 T1.75 T1.75 T1.75 T3.25 SC Midg Flanged Midget Groove BA9S SC Midg Flanged SC Midg Flanged SC Midg Flanged Midget Groove Mini Bayonet 1500 4000 200 15000 10000 7000 7000 3000 6.28 4.
030_MIN_F_print.qxd 12/12/07 3:12 PM Page 74 MINIATURE & AUTOMOTIVE LAMPS 17 M I N I A T U R E Ordering Abbreviation Product Number Bulb Base Avg Rated Life (hrs) 912 918 918/2PK/RP 13V 93 93BL2PK 13V 94 NE51 B1A NE51H B2A 35869 35923 35921 34311 16810 34337 32427 32429 T5 T5 T5 S8 S8 S8 T3.25 T3.25 W2.1x9.2D W2.1x9.2D W2.1x9.2D SC Bayonet SC Bayonet DC Bayonet Mini Bayonet Mini Bayonet 1000 500 500 700 700 700 25000 25000 150.8 81.62 81.68 188.5 188.49 187.
040_HID_drop.qxd 12/12/07 3:14 PM Page 75 OSRAM SYLVANIA: THE LEADER IN ENERGY-SAVING HID LAMPS UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING A brief description of the catalog format and related terminology will assist the reader in understanding the information presented in this section. All product families are listed in ascending wattage, followed by alphabetical bulb designation to simplify lamp identification.
040_HID_drop.qxd 12/12/07 3:14 PM Page 76 UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING (continued) FIXTURE REQUIREMENT (continued) LUMENS The 2005 NEC also requires that metal halide luminaires for new contruction/major renovations in the playing and spectator areas of indoor sports, mixed use, and all purpose facilities, which are subject to physical damage, must be of a type that protects the lamp with a glass or plastic lens. Open luminaires will not be permitted.
040_HID_drop.qxd 12/12/07 3:14 PM Page 77 BULBS A bulb designation consists of a letter(s) to indicate the shape and a number(s) to indicate the approximate maximum diameter in eighths of an inch. Thus, an E17 lamp is an Ellipsoidal shape and 17/8 of an inch or 2 1/8 inches in diameter. Other letter designations include: BT=Bulbous Tubular; E or ED=Ellipsoidal; ET=Ellipsoidal Tubular; PAR=Parabolic; R=Reflector; T=Tubular. E17 ET18 ET23.
040_HID_drop.qxd 12/12/07 3:14 PM Page 78 HID BRAND NAME GUIDE Note: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather than an identical match. Individual manufacturer’s performance values should be consulted.
040_HID_drop.qxd 12/12/07 3:14 PM Page 79 The following items were accepted into the 2006 IESNA Progress Report, which recognizes innovative products introduced to the industry during that year. 20-watt PAR30 METALARC POWERBALL 39-watt PAR20 METALARC POWERBALL 39-watt PAR30 METALARC POWERBALL 750-watt METALARC Metal Halide H I D LAMP DISPOSAL LABELING The following information appears on the packages of high intensity discharge lamps that contain mercury.
040_HID_drop.qxd 12/12/07 3:14 PM Page 80 GUIDE TO METAL HALIDE LAMPS METALARC® Metal Halide lamps are designed for general lighting applications such as commercial, industrial lighting and outdoor floodlighting where good color and high efficiency are desired.
040_HID_drop.qxd 12/12/07 3:14 PM Page 81 Enclosed fixture rated METALARC®, E-Type Lamp R ANSI Luminaire Code E ENCLOSED FIXTURE THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed of a UV-attenuating outer quartz bulb with an internal arc-tube.
040_HID_drop.qxd 12/12/07 3:14 PM Page 82 Enclosed fixture rated METALARC® E-Type (Ceramic & Quartz, G12, G8.5 & DE, UV-Stop Outer-jacket) Lamp R ANSI Luminaire Code E ENCLOSED FIXTURE THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal ceramic or quartz arc-tube.
040_HID_drop.qxd 12/12/07 3:14 PM Page 83 Open Fixture Rated, METALARC PRO-TECH®, O-Type Lamp R ANSI Luminaire Code O OPEN FIXTURE permissible THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube.
040_HID_drop.qxd 12/12/07 3:14 PM Page 84 METALARC®, S-Type Lamp R ANSI Luminaire Code S ENCLOSED FIXTURE/Open if meets requirement of Paragraph I.1 below THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube.
040_HID_drop.qxd 12/12/07 3:14 PM Page 85 METALARC® SAFELINE®, S-Type Lamp T ANSI Luminaire Code S ENCLOSED FIXTURE/Open if meets requirement of Paragraph I.1 below THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube.
040_HID_drop.qxd 12/12/07 3:14 PM Page 86 METALARC® BRITELINE, F-Type Lamp ANSI Luminaire Code F ENCLOSED FIXTURE with UV filter and lens interlock required THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE. I. RUPTURE RISKS: This Metal Halide lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures.
040_HID_drop.qxd 12/12/07 3:14 PM Page 87 GUIDE TO HIGH PRESSURE SODIUM LAMPS DOME MOUNT SUPPORT HERMETIC END SEAL STEEL FRAME ALUMINA ARC-TUBE WEATHER RESISTANT GLASS ENVELOPE VACUUM RESIDUE GAS GETTER BRASS DATE RECORDING BASE High Pressure Sodium lamps are one of the most efficient HID sources available today. These lamps are used for general lighting applications where high efficiency and long life are desired while color rendering is not critical.
040_HID_drop.qxd 12/12/07 3:14 PM Page 88 WARNING LUMALUX® Double-Ended Quartz Jacketed Lamps I. ANSI LUMINAIRE Code F ENCLOSED FIXTURE with UV Filter and lens interlock required OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which has an ANSI designation identical to that found on the lamp outer glass bulb. II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 2 PER ANSI-IESNA Rp-27.396.
040_HID_drop.qxd 12/12/07 3:14 PM Page 89 GUIDE TO MERCURY VAPOR LAMPS OSRAM SYLVANIA Mercury lamps are designed primarily for use in general lighting applications where good efficiency and long life are desired while color rendering requirements are moderate. Applications include street lighting, industrial hi-bay, parking lot lighting, and general flood-lighting.
040_HID_drop.qxd 12/12/07 3:14 PM Page 90 GUIDE TO REPROGRAPHIC LAMPS TUNGSTEN ELECTRODES QUARTZ BULB MOLYBDENUM FOIL OSRAM SYLVANIA reprographic lamps are designed for applications other than general lighting. These applications include: plate making, photo resist exposure, imaging and other requiring the use of ultraviolet energy.
040_HID_F_print.qxd T (G8.5 base) 12/17/07 8:29 AM T (G12 base), T (G22 base) Page 91 T (RSC base) PAR30 LN PAR20 POWERBALL® CERAMIC METALARC® TUBULAR SINGLE-ENDED High CRI, Pulse Start, UV Stop – Enclosed Fixtures Only 4 Watts Bulb Base Product Number Ordering Abbreviation 20 G8.5 64882 T4.5 MC20TC/U/G8.
040_HID_F_print.
040_HID_F_print.qxd 12/17/07 E17, E17/ED17 8:29 AM Page 93 BT28, BT28/ED28, BT28/ET23.
040_HID_F_print.
040_HID_F_print.
040_HID_F_print.
040_HID_F_print.
040_HID_F_print.qxd BT37 12/17/07 8:29 AM T (RSC base) Page 98 R30/R40 T (G12 base) ET23.
040_HID_F_print.qxd 12/17/07 E17 8:29 AM ET23.5, BT28 Page 99 ET18 E25 BT37 T (Mog base) LUMALUX PLUS®AND LUMALUX PLUS® ECO® Non-Cycling High Pressure Sodium 4 ANSI Code Avg Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols & Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes Watts Bulb Base Product Number Ordering Abbreviation 100 E17 E26 Medium 67323 LU100/PLUS/MED S54 20 Clear Universal O 30000 10000 9000 22 2100 4,8 ET23.
040_HID_F_print.qxd ET23.5, ED28, BT28 12/17/07 ET18 8:30 AM E25 Page 100 T (RSC base) T (Mog base) E17 PAR38 R30/R40 ED37 BT56 T (BY22D base LUMALUX ®STANDBY Dual Arc Tube,Long Life 4 H I D ANSI Code Avg Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols & Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes Watts Bulb Base Product Number Ordering Abbreviation 70 ET23.
040_HID_F_print.qxd 12/17/07 8:30 AM Page 101 SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS Symbol Description New item introduced within the past year. Item will be discontinued when inventory is depleted. New item introduced within the past year. This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal regulations may vary; check local and state regulations.
040_HID_F_print.qxd 12/17/07 8:30 AM Page 102 SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS H I D Footnote Description 32 Do not operate on dimming systems. Dimming systems will prevent a lamp the ability to self-extinguish. 33 When operating on a ballast with a sustaining voltage less than 310V, lamp life may be significantly reduced. 34 In general, Horizontal lumen values will be 5-10% lower than the vertical lumen values.
100_cref.qxd 12/17/07 8:27 AM Page 103 Manufacturers’ Cross Reference HIGH INTENSITY DISCHARGE LAMPS SYLVANIA GE PHILIPS METALARC CERAMIC METAL HALIDE MC150T7.5/U/G12/940 PB MC70T6/U/G12/940 PB MC150T7.5/G12/U/830 PB MC39T6/U/G12/830 PB MCP70/U/MED/830 PB MCP70/C/U/MED/830 PB MCP100/U/MED/830 PB MCP100/C/U/MED/830 PB MCP70PAR38/U/SP/830/ECO PB MCP70PAR38/U/FL/830/ECO PB MCP70PAR38/U/VWFL/830/ECO PB MCP100PAR38/U/SP/830/ECO PB MCP100PAR38/U/FL/830/ECO PB MCP100PAR38/U/VWFL/830/ECO PB MC39TC/U/G8.
100_cref.
100_cref.
100_cref.
050_CFL_drop.qxd 12/12/07 3:50 PM Page 107 OSRAM SYLVANIA: THE LEADER IN ENERGY SAVING COMPACT FLUORESCENT LAMPS The compact fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate ultra-violet (plus a little visible) energy.
050_CFL_drop.qxd 12/12/07 3:50 PM Page 108 HOW TO READ PRODUCT INFORMATION - COMPACT FLUORESCENT Avg Nominal MOL Wattage Bulb (in) (mm) Base Product NEMA Generic Number Ordering Abbreviation Designation Pkg Qty Avg Rated CCT Life (hrs) (K) 13 29116 6 8000 Twist 4.6 117 Med CF13EL/MINITWIST Approx Lumens Initial Mean CRI @25°C/77°F (@35˚C/95˚F) 3000 82 800 Symbols & Footnotes 640 | | | | 2,21,28, 36,63,64 26 D(T4) 6.
050_CFL_drop.qxd 12/12/07 3:50 PM Page 109 For weight and measurement information, please visit www.sylvania.com Lamp Disposal Labeling The following information appears on packages of fluorescent lamps. For more information on lamp disposal labeling, see the inside back cover of this catalog. Hg C O M P A C T Lamp Contains Mercury Manage in accordance with disposal laws See www.lamprecycle.
050_CFL_drop.qxd 12/12/07 3:50 PM Page 110 COMPACT FLUORESCENT LAMPS The overall length of DULUX® compact fluorescent lamps is measured from the bottom of the base to the outside edge of the glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp.
050_CFL_drop.qxd 12/12/07 3:50 PM Page 111 BASES Pin-based compact fluorescent lamps have either 2 pins or 4 pins. Each 2-pin lamp has an internal starter and is designed for preheat, magnetic operation. The 4-pin lamps are designed for electronic ballast operation and are dimmable. These lamps have no internal starter; starting the lamps is a function of the ballast. Medium screw base, compact fluorescent lamps have integral ballasts.
050_CFL_drop.
050_CFL_drop.
050_CFL_print.qxd 12/17/07 8:41 AM Page 114 DULUX® S DULUX S PREHEAT 2-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS With starter in Lamp Base for Magnetic Ballast 42 Nominal Wattage Bulb MOL (in) (mm) Base Product Number Ordering Abbreviation NEMA Generic Designation Pkg Qty Avg Approx Lumens Rated CCT Initial Mean Symbols & Life (hrs) (K) CRI @25°C/77°F Footnotes 5 4.
050_CFL_print.qxd 12/17/07 8:41 AM DULUX® S/E Page 115 DULUX® D DULUX S/E 4-PIN COMPACT FLUORESCENT LAMPS for Dimming and Electronic Ballast. Lamps have End-of-lamp Life (EOL) Protection 42 Nominal Wattage Bulb MOL (in) (mm) Base 5 3.4 7 9 13 S (T4) S (T4) S (T4) S (T4) 4.5 5.7 6.
050_CFL_print.qxd 12/17/07 DULUX® D 8:41 AM Page 116 DULUX® T DULUX® D/E 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS for Dimming and Electronic Ballast. Lamps have End-of-lamp Life (EOL) Protection 42 Nominal Wattage Bulb MOL (in) (mm) Base Product Number Ordering Abbreviation NEMA Generic Designation Pkg Qty Avg Approx Lumens Rated CCT Initial Mean Symbols & Life (hrs) (K) CRI @25°C/77°F Footnotes 13 5.
050_CFL_print.qxd 12/17/07 8:41 AM Page 117 DULUX® T DULUX® D/E 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS 42 Nominal Wattage Bulb MOL (in) (mm) Base 26 5.
050_CFL_print.qxd 12/17/07 DULUX® T 8:41 AM Page 118 DULUX® L DULUX® T/E/IN AMALGAM, 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS 42 Avg Nominal Wattage Bulb (in) 57 7.
050_CFL_print.qxd 12/17/07 8:41 AM DULUX® L Page 119 DULUX® F DULUX® EL Twist DULUX® L HIGH LUMEN ECOLOGIC® COMPACT FLUORESCENT LAMPS 42 Nominal Wattage Bulb MOL (in) (mm) Base Product Number Ordering Abbreviation NEMA Generic Designation 50 22.6 20280 FT50W/2G11/RS/830 10 L (T5) 573 2G11 FT50DL/830/RS/ECO Pkg Qty Avg Approx Lumens Rated CCT Initial Mean Symbols & Life (hrs) (K) CRI @25°C/77°F Footnotes 14000 3000 82 4300 3655 | | | 1,2,5,12, 20 55 L (T5) 21.
050_CFL_print.qxd 12/17/07 8:41 AM Page 120 DULUX® EL Twist DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS Mini Twist Compact Fluorescent Lamps 44 Nominal Wattage Bulb MOL (in) 13 4.6 MINITWIST Avg Base Product Number Medium 29727 Ordering Abbreviation Pkg Voltage Qty Avg Rated CCT Life (hrs) (K) CF13EL/MICRO/830/RP2 120 12000 12 Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 3000 82 825 660 | | | 1,3,8, 9,12,14,20 4.
050_CFL_print.qxd 12/17/07 8:41 AM DULUX® EL Twist Page 121 DULUX® EL Classic DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS Twist Compact Fluorescent Lamps 44 Nominal Wattage Bulb MOL (in) 27 6.1 TWIST Avg Base Product Number Medium 29390 Ordering Abbreviation Pkg Voltage Qty Avg Rated CCT Life (hrs) (K) CF27EL/TWIST/830 120 10000 6 Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 3000 82 1750 1400 | | | 1,3,8, 9,12,14,20 30 TWIST 5.
050_CFL_print.qxd 12/17/07 DULUX® EL Globe 8:41 AM Page 122 DULUX® EL Reflector FLAME DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS Decorative Compact Fluorescent Lamps 44 Nominal Wattage Bulb MOL (in) 5 5.06 FLAME Avg Base Product Number Medium 29742 Ordering Abbreviation Pkg Voltage Qty Avg Rated CCT Life (hrs) (K) CF5EL/B10/DIM/830 120 25000 6 Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 3000 82 200 160 | | | 1,3,8, 9,12,14,20 7 FLAME 5.
050_CFL_print.qxd 12/17/07 8:41 AM DULUX® EL Dura-One Page 123 DULUX® EL Bullet DULUX® EL Reflector DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS Reflector Compact Fluorescent Lamps 44 Nominal Wattage Bulb MOL (in) 23 6.25 PAR38 Avg Base Product Number Medium 29897 Ordering Abbreviation Pkg Voltage Qty Avg Rated CCT Life (hrs) (K) CF23EL/PAR38/GL/827 120 8000 6 Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 2700 82 1000 800 | | | 1,3,8, 9,12,14,20 BR40 6.
050_CFL_print.qxd 12/17/07 8:41 AM Page 124 SYMBOLS & FOOTNOTES FOR COMPACT FLUORESCENT LAMPS Symbol Description New item introduced within the past year. Item will be discontinued when inventory is depleted. This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal regulations may vary; check local and state regulations.
100_cref.
100_cref.
100_cref.
100_cref.qxd 12/13/07 9:44 AM Page 128 Notes: C O M P A C T F L U O R E S C E N T For more complete product information visit www.sylvania.
055_FL_drop.qxd 12/12/07 3:38 PM Page 129 OSRAM SYLVANIA: THE LEADER IN ENERGY SAVING FLUORESCENT LAMPS The fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate ultra-violet (plus a little visible) energy. The ultra-violet energy is absorbed by a phosphor coat on the inside of the glass tube and converted by the phosphor to visible wavelengths; the wavelengths of the light generated are determined by the composition of the phosphor.
055_FL_drop.qxd 12/12/07 3:38 PM Page 130 HOW TO READ PRODUCT INFORMATION - FLUORESCENT Avg F L U O R E S C E N T CCT (K) CRI Approx Lumens Initial Mean @25°C/77°F Symbols & (@35˚C/95˚F) Footnotes Ordering Abbreviation Pkg Qty Avg Rated Life (hrs) Med Bipin 21763 FO32/835XP/ECO 30 24000 3500 85 3000 2850 2,21,31, 35,39,60,70 47.78 Med Bipin 24594 F34CW/SS Formerly F40CW/SS 30 20000 4200 60 2650 2279 2,10,13, 19,21,42 48 45.
055_FL_drop.
055_FL_drop.qxd 12/12/07 3:38 PM Page 132 FLUORESCENT COMPETITIVE GUIDES NOTE: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather than an identical match. Individual manufacturer’s performance values should be consulted. Environmental conditions, ballast type, and other auxiliary equipment may affect lamp performance.
055_FL_drop.qxd 12/12/07 3:38 PM Page 133 FLUORESCENT COMPETITIVE GUIDES (continued) FLUORESCENT ELECTRICAL INTERCHANGEABILITY SYLVANIA GE PHILIPS F24"T8/CW/4 F26"T8/CW/4 F28"T8/CW/4 F30"T8/CW/4 F34CW/WM F40CW/WM F96T12/CW/WM F40/SP41/U/6 F40CW/U/6/WM (new F34CW/U/6/WM) T8 (was Trimline) T8 SP T8 SPX F17T8/SP(or SPX)… F25T8/SP(or SPX)… F32T8/SP(or SPX)… F32T8/XL/SP (or SPX) --F32T8/SP…/IS/WM/ECO ----F40T8/SP… (or SPX) --F96T8/SP… (or SPX) F96T8/XL.SP... F96T8/XL/SPX...
055_FL_drop.qxd 12/12/07 3:38 PM Page 134 FLUORESCENT LAMPS F L U O R E S C E N T The bulb shape and size of a fluorescent lamp are expressed by means of a code consisting of the letter “T” (which designates that the bulb is “tubular” in shape) followed by a number that expresses the diameter in eighths of an inch. Diameters range from T2 (1⁄4 inch) to T17 (2 1⁄8 inch). In nominal overall length, linear fluorescent lamps range from 6 to 96 inches.
055_FL_print.qxd 12/12/07 3:39 PM Page 135 T8 Med Bipin OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® lamps are T8 fluorescent lamps designed to be operated on dedicated magnetic rapid start or electronic instant start or programmed rapid start (also known as programmed start) ballasts. For details on various lamp/ballast system combinations, please refer to the Systems Performance Guide in the "SYLVANIA QUICKTRONIC® Ballast Technology and Specification Guide".
055_FL_print.qxd 12/12/07 3:39 PM Page 136 T8 Med Bipin OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® 800 XP® 4 Foot SUPERSAVER® Lamps 40 Nominal Wattage Bulb Nominal Length MOL (in) (in) 30 48 T8 47.
055_FL_print.qxd 12/12/07 3:39 PM Page 137 T8 Med Bipin OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® 800 XP® Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 25 36 T8 35.
055_FL_print.qxd 12/12/07 3:39 PM Page 138 T8 Med Bipin OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® 800 Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 17 24 T8 23.
055_FL_print.qxd 12/12/07 3:39 PM T8 Med Bipin Page 139 T8 Single Pin T8 RDC OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® 700 Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 25 36 T8 35.
055_FL_print.
055_FL_print.qxd 12/12/07 3:39 PM T8 U-Shaped 1-5/8" Page 141 T8 U-Shaped 6" OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® CURVALUME® U-SHAPED Lamps - 1 5/8” Leg Spacing 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 16 10.5 T8 10.
055_FL_print.qxd 12/12/07 3:39 PM T8 U-Shaped 6" Page 142 T8 Med Bipin T8 U-Shaped 1-5/8" OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS OCTRON® 700 CURVALUME® U-SHAPED Lamps - 6” Leg Spacing 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 32 22.5 T8 22.
055_FL_print.qxd 12/12/07 3:39 PM Page 143 T5 Mini Bipin PENTRON® T5 FLUORESCENT LAMPS PENTRON® T5 lamps are designed to operate on dedicated electronic programmed rapid start (also know as programmed start) ballasts only. These lamps are globally standardized and are designed to operate with their peak light output at 35°C (95°F) ambient temperature. For comparison purposes and to accommodate existing lamp measurement standards, ratings are given at both 25°C (77°F) and 35°C (95°F).
055_FL_print.qxd 12/12/07 3:39 PM Page 144 T5 Mini Bipin PENTRON® T5 FLUORESCENT LAMPS PENTRON® High Output, High Performance T5 Lamps 45 Avg Nominal Wattage Bulb Nominal Length (in) 54 T5 48 MOL (in) Product Number Ordering Abbreviation Base 45.8 Mini Bipin 20903 20904 21020 20906 21021 F L U O R E S C E N T 20949 21022 20862 24 T5 24 22.2 36 34 60 57.
055_FL_print.qxd 12/12/07 3:39 PM Circline 4-Pin T5 Page 145 T12 Med Bipin PENTRON® T5 FLUORESCENT LAMPS PENTRON® Circline T5 Lamps 46 Nominal Wattage 22 40 55 Avg Bulb Outside Diameter (in) T5 8.66 - 9.06 T5 11.54 - 12.01 T5 11.54 - 12.
055_FL_print.qxd 12/12/07 3:39 PM Page 146 T12 Med Bipin RAPID START LAMPS 4’ SUPERSAVER® Rapid Start Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 34 48 T12 47.
055_FL_print.qxd 12/12/07 3:39 PM T12 Med Bipin Page 147 T12 U-Shaped 6" RAPID START LAMPS 4’ Standard Rapid Start Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 40 48 T12 47.
055_FL_print.qxd 12/12/07 3:39 PM T12 U-Shaped 6" Page 148 Circline 4-Pin T9 T12 RDC RAPID START LAMPS CURVALUME® Standard Rapid Start Lamps – U-Shaped, 6” Leg Spacing 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 40 22.5 T12 22.
055_FL_print.qxd 12/12/07 3:39 PM Page 149 T12 RDC RAPID START LAMPS High Output (800mA) Standard Rapid Start Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 42 T12 30 45 T12 36 55 60 75 80 85 100 110 T12 T12 T12 T12 T12 T12 T12 42 48 60 64 72 84 96 Base Product Number Ordering Abbreviation Pkg Qty Avg Rated Life CCT @3hrs/start (K) Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 27.
055_FL_print.qxd 12/12/07 3:39 PM T12 RDC Page 150 T12 Single Pin RAPID START LAMPS High Output (800mA) Standard Rapid Start Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 110 96 T12 93.
055_FL_print.
055_FL_print.
055_FL_print.qxd 12/12/07 3:39 PM T5 Mini Bipin Page 153 T8 Med Bipin T12 Med Bipin PREHEAT LAMPS Miniature T5 Preheat Lamps (Starter Required) 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 4 T5 6 6 T5 9 8 13 T5 T5 12 21 Base Product Number Ordering Abbreviation Pkg Qty Avg Rated Life CCT @3hrs/start (K) Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes 5.
055_FL_print.qxd 12/12/07 3:39 PM T12 Med Bipin Page 154 T8 Med Bipin PREHEAT LAMPS Standard T8 and T12 Preheat Lamps (Starter Required) 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 15 18 18 T12 T8 24 26 F L U O R E S C E N T 28 20 25 30 T12 T12 T8 17.78 23.78 25.78 27.
055_FL_print.qxd 12/12/07 3:39 PM T8 Med Bipin Page 155 T12 Med Bipin T5 Mini Bipin T12 Single Pin T14 1/2 RDC T2 Axial Base SPECIALTY FLUORESCENT LAMPS SAFELINE® Shatter Resistant Coated Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 32 48 T8 47.
055_FL_print.qxd 12/12/07 3:39 PM T2 Axial Base Page 156 Icetron SPECIALTY FLUORESCENT LAMPS Miniature T2 Lamps 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 11 16.6 T2 16.6 Base Product Number Ordering Abbreviation Pkg Qty Avg Rated Life CCT @3hrs/start (K) Approx Lumens Initial Mean Symbols & CRI @25°C/77°F Footnotes Axial 26235 20 10000 80 FM11/835 3000 750 675 | | | 3,31,33,38,48,74, 118 26231 FM11/841 20 10000 4100 80 750 675 3,31,33,38,48,74, 118 13 T2 20.
055_FL_print.qxd 12/12/07 T12 Med Bipin 3:39 PM Page 157 T8 Med Bipin T12 RDC T5 Mini Bipin CFL 2Pin CFL 4 Pin SPECIALTY FLUORESCENT LAMPS Diazo (SDB) 41 Nominal Wattage Bulb Nominal Length MOL (in) (in) 65 48 T12 47.
055_FL_print.
055_FL_print.qxd 12/12/07 3:39 PM Page 159 FLUORESCENT PREHEAT LAMP STARTERS GLOSTAT Starters 47 Product Number Ordering Abbreviation Pkg Qty 44902 FS-4/BL/2PK 12 Fluorescent starter for use with F13, F30 and F40 preheat lamps, blister pack with 2 starters. UL, CSA 45812 FS-5 100 Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps. UL, CSA 45813 FS-5/BL/2PK 12 Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps, blister pack with 2 starters.
055_FL_print.qxd 12/12/07 3:39 PM Page 160 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS Symbol Description New item introduced within the past year. Item will be discontinued when inventory is depleted. Rating given for 200mA operation. This fluorescent lamp generates radiant energy which is most beneficial for plant propagation and enhances vegetative and reproductive growth of many plants for home and commercial use. This lamp or ballast meets minimum Federal efficiency standards.
055_FL_print.qxd 12/12/07 3:39 PM Page 161 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS Footnote Description 18 IF AN OPERATING LAMP IS EXPOSED TO TEMPERATURES BELOW 70˚F OR MOVING AIR (WIND, DRAFTS OR AIR FLOW FROM AN AIR CONDITIONING OR VENTILATION SYSTEM) STRIATION, A RHYTHMIC PULSING PATTERN OF LIGHT RUNNING THE LENGTH OF THE TUBE AND/OR A REDUCTION IN LIGHT OUTPUT MAY OCCUR.
055_FL_print.qxd 12/12/07 3:40 PM Page 162 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS F L U O R E S C E N T Footnote Description 36 These lamps may also be operated on rapid start circuits. On rapid start circuits the 24 watt lamp operates at 27 watts and the 36 watt lamp operated at 39 watts. Rated lamp life is unchanged. 37 Lumen output rated on high frequency operation. 60 HZ operation would result in lower lumen output. 38 Lumen output and life rated on high frequency operation.
055_FL_print.qxd 12/12/07 3:40 PM Page 163 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS Footnote Description 73 For use with GL-1302 GRO-LUX fixture. 74 There is a NEMA supported, industry issue where T2, T4, and T5 fluorescent and compact fluorescent lamps operated on high frequency ballasts may experience an abnormal end-of-life phenomenon. This end-of-life phenomenon can resulting one or both of the following: 1. Bulb wall cracking near the lamp base. 2.
055_FL_print.qxd 12/12/07 3:40 PM Page 164 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS F L U O R E S C E N T Footnote Description 96 SAFELINE lamps satisfy the criteria of having a non-shattering covering for prevention of glass and other lamp components in your product by containment within the safety coating material. The covering must be intact or the lamp must be replaced to be in compliance.
055_FL_print.qxd 12/12/07 3:40 PM Page 165 SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS Footnote Description 108 Average life rating at 12 hours operation per start is 15,000 hours. 109 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than 0.75 meters (30 inches) should be limited; for example exposure at 0.55m (22 inches) should not exceed 4 hours in an 8 hour interval (see ANSI/IESNA RP-27.1-96).
100_cref.
100_cref.
100_cref.
100_cref.
100_cref.qxd 12/12/07 12:32 PM Page 170 Notes: F L U O R E S C E N T For more complete product information visit www.sylvania.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.qxd:Empty E L E C T R O N I C B A L L A S T S 12/18/07 10:43 AM Page 172 The System is the Solution QUICKTRONIC® High Efficiency High Efficiency Series products are energy-saving electronic T8 ballasts that save additional 6% (2 to 5 watts) over standard electronic ballasts. Features also include <10%THD and Universal Voltage.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 173 Table of Contents QUICKTRONIC Ballasts for T5HO, T5, DL40, T4 Systems QUICKTRONIC® Electronic Ballasts . . . . . . . . . . . . . . . .176-184 Professional T5HO PROStart <10% THD Universal Voltage Normal BF . . . . . . . . . . . . . . . .181 LED Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185 Discontinued Electronic Ballasts/Replacement List . . . .186-187 QUICKCROSS Electronic Mfrs. Cross Reference . . . .
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 174 The Original System Solution Key System Features: The first matched T8 lamp and ballast systems for optimized performance and longer life.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 175 MULTIWATT QUICKSENSE® New electronic ballasts that offer the versatility to operate multiple The patented end-of-lamp-life sensing technology that helps lamp types of various wattages. These multi-watt and multi-lamp models also can vary the number of lamps operated (i.e. 1 or 2 prevent lamp overheating and established the benchmark for industry recommendations for T5 and smaller diameter lamps.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 176 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) All data shown is for primary lamp types only. Complete performance data is available in the SYLVANIA QUICKTRONIC® Electronic Ballast Technology & Specification Guide and at www.sylvania.com Input Current (AMPS) Lamp Type Rated Lumens (lm) No.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 177 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor (BF) System Lumens Mean Lumens1 Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® PROFESSIONAL 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS LOW BALLAST FACTOR QTP1x32T8/UNV ISL-SC 49832 49741 49742 Banded Pack 10-Pack Pallet Pack 120-277 0.22/0.10 0.22/0.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 178 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor (BF) System Lumens Mean Lumens1 Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® HIGH EFFICIENCY SYSTEMS 32 T8 PROStart® PSX UNIVERSAL VOLTAGE SYSTEMS Xtreme SYSTEMS – LOW BALLAST FACTOR QTP 1x32T8/UNV PSX-TC 51224 51420 Banded Pack 10-Pack 120-277 0.21/0.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 179 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Ballast Lumens No.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 180 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Rated Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor (BF) System Lumens Mean Lumens1 Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® HIGH EFFICIENCY 32 T8 INSTANT START 347 VOLT SYSTEMS – CANADA LOW BALLAST FACTOR E L E C T R O N I C B A L L A S T S 49471 QHE 1X32T8/347 ISL-SC 347 0.08 0.08 0.07 0.07 0.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 181 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor (BF) System Lumens Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® PROFESSIONAL T5HO PROStart® PSN UNIVERSAL VOLTAGE SYSTEMS NORMAL BALLAST FACTOR 3 49111 QTP 2x39-24T5HO/UNV PSN NL 120-277 0.47/0.20 FP24T5HO 2000 2 1 1.00 1.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 182 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 183 Electronic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor (BF) System Lumens Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® PROFESSIONAL DALI DIMMING SYSTEMS - 100-1% Dimming Range - <10% THD - For a list of DALI controllers, contact OSRAM SYLVANIA T8 51350 QTP 1x32T8/UNV DALI 120-277 0.31/0.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 184 Electronic Fluorescent / Metal Halide Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Rated Lumens (lm) Lamp Type No. of Lamps Ballast Factor (BF) System Lumens Input Wattage (W) System Efficacy (lm/W) QUICKTRONIC® PROFESSIONAL 40 T12 RAPID START NORMAL BALLAST FACTOR - <10%THD, (3 lamp <20%THD) 50684 QTP 1x40T12/120 RSN-SC 120 0.30 F40T12/D41 3200 1 0.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 185 LED Power Supplies Item Number OSRAM SYLVANIA Description Nominal Input Voltage (VAC) Nominal Input Current (Amps) Output Current (mA) Remote Mounting (ft) Location Rating Dimming Range Control Voltage OPTOTRONIC® Electronic DRAGON Power Supplies OSRAM Constant Current LED DRAGON Power Supplies (DC Output) - Contact OSRAM SYLVANIA for DRAGON™ LED module ordering information AC Input 51524 = OT3/120-240/350 120-240 (AC) 0.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 188 Electronic Ballast Cross Reference Guide QUICKCROSS Item Number The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. OSRAM SYLVANIA Advance U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 189 Electronic Ballast Cross Reference Guide The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. Item Number OSRAM SYLVANIA U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 190 Electronic Ballast Cross Reference Guide QUICKCROSS Item Number The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. OSRAM SYLVANIA U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 191 Electronic Ballast Cross Reference Guide The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. Item Number OSRAM SYLVANIA Advance U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 192 Electronic Ballast Cross Reference Guide QUICKCROSS Item Number OSRAM SYLVANIA POWERSENSE® (2 wire Powerline & 0-10V) (120-277V) The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. Advance Mark 10 (2 wire) Mark 7 Powerline (0-10V) (Dedicated Voltage) (120-277V) U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 193 Electronic Ballast Cross Reference Guide The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition. Item Number OSRAM SYLVANIA U.L.T.
PLG_graycale_2008_FINAL.qxd:Empty M A G N E T I C B A L L A S T S 12/18/07 10:43 AM Page 194 Magnetic Ballasts Simplified Solutions Magnetic Ballasts OSRAM SYLVANIA is focused on helping our customers understand our products, and to simplifying their use and applications. SYLVANIA magnetic fluorescent product labels include an industry first — a handy cross-reference guide to help identify the proper ballast for replacing existing installed products.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 195 Table of Contents – Magnetic Ballasts Fluorescent Magnetic Ballasts................................................. 198-199 with Competitive Mfrs. Cross Reference HID Magnetic Ballasts ............................................................. 200-205 with Competitive Mfrs. Cross Reference Magnetic Ballasts Magnetic Fluorescent Ballasts for T8, T12, T10, T9 & T5 lamps F017T8 Rapid Start, High PF ...........................................
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 196 Energy Legislation Update On April 1, 2005 the 2000 Federal Ballast Efficacy ballast efficacy standards for ballasts capable of operating Regulations were implemented to raise the minimum Ballast full and reduced wattage F40T12, F40T12/U, F96T12 and Efficacy Factor (BEF) for T12 fluorescent ballasts. The ruling F96T12HO lamps have been set in EPAct 2005.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 197 DISTRIBUTOR / REPLACEMENT MARKET 2000 Federal Ballast Efficacy Regulations Ballast manufacturers can manufacture and sell to distributors, fluorescent ballasts for Full-Wattage F40T12, F40T12/U, F96T12 and F96T12HO that do not meet the OSRAM SYLVANIA will continue to supply the Magnetic Fluorescent Ballasts listed below for T12 lamps until July 1, 2010 (for replacement purposes only): minimum Ballast Efficacy Factor (BEF) until July 1, 2010.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 198 Magnetic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) No.
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 199 Magnetic Fluorescent Ballasts Item Number OSRAM SYLVANIA Description Input Voltage (VAC) No.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
PLG_graycale_2008_FINAL.
071_DO_drop.qxd 12/13/07 3:25 PM Page 207 OSRAM BRAND DISPLAY/OPTIC LIGHT SOURCES Lighting to provide solutions in diverse applications such as cinema film projection, effect lighting, stage, studio, TV, display and projection systems, microlithography, medical/scientific, industrial, and airfield/aircraft.
071_DO_drop.
071_DO_drop.qxd 12/13/07 3:25 PM Page 209 OSRAM Airfield Lamps Effective solutions for airfield lighting around the globe. IRC Reflector IRC PK30d PK30d R7s GZ(Y)9.5 OSRAM lamps for the airfield lighting industry provide reliable solutions for complex optical systems. State-of-the-art manufacturing yields high quality lamps with precision filament alignment that is required in these demanding applications.
071_DO_drop.qxd 12/13/07 3:25 PM Page 210 OSRAM aluPAR® Lamps with aluminum reflector lighter, brighter, cooler D I S P L A Y O P T I C H A L O G E N Seeing is believing! Don’t get weighed down with old technology! Features and Benefits • Applications Tungsten halogen aluPAR lamps are made with an aluminum reflector which makes them up to 50% lighter than standard glass PAR lamps.
072_DOH_print.qxd 12/12/07 MR11, MR13, MR16 2:58 PM Page 211 A21, A23 Bi-Pin Med 2-pin GZ9.5 PS25 AUDIOVISUAL 11 Avg Rated Life(hrs) Bulb Pkg Qty 2000 MR16 24 8700 4 A21 12 G6.35 5600 50 T3.25 40 58 12 G6.35 1600 50 T3 40 58 1200 120 G17t 20 T7 24 13,58 Projector, Microfilm, Stage & Studio 625 120 GY9.5 50 T6 24 58 CAX Projector, Microfilm, Microscope, Studio 50 120 DC Bayonet 250 T4 24 54660 DDL Projector - Microfilm 150 20 GX5.
072_DOH_print.qxd 12/12/07 MR11, MR13, MR16 2:58 PM Page 212 Bi-Pin AUDIOVISUAL 11 D I S P L A Y O P T I C H A L O G E N Application Watts Volts Base Lumens Avg Rated Life(hrs) EKE Projector - 8mm, Fiber-Optics 150 21 GX5.3 160 200 MR16 24 117 58771 EKE/X Projector - 8mm, Fiber-Optics 150 21 GX5.3 80 1000 MR16 24 117 EKP/ENA 54734 EKP/ENA Projector - 8mm 80 30 GX5.3 115 25 MR16 24 117 ELC 54840 ELC Overhead projection, 250 fiber-optic, entertainment 24 GX5.
072_DOH_print.qxd Bi-Pin 12/12/07 2:58 PM Page 213 MR11, MR13, MR16 Med 2-pin GZ9.5 B15d E14 AUDIOVISUAL 11 Application Watts Volts Base Lumens Avg Rated Life(hrs) EYB Projector, Stage & Studio 360 82 G5.3 10000 75 T3.5 24 58 54448 EYB-5 Projector, Microfilm, Stage & Studio 360 85.5 G5.3 10000 75 T3.5 24 58 EYB-7 54455 EYB-7 Projector, Microfilm, Stage & Studio 360 87.5 G5.3 10000 75 T3.5 24 58 EZE 54386 EZE Projector, Stage & Studio 150 82 GX5.
072_DOH_print.qxd Bi-Pin 12/12/07 2:58 PM MR11, MR13, MR16 Page 214 Med 2-pin AUDIOVISUAL 11 ANSI Code D I S P L A Y O P T I C H A L O G E N Lumens Avg Rated Life(hrs) Bulb Pkg Qty G4 150 300 T3 100 6 G4 150 300 T3 40 6 PG22 500 100 T3 30 20 8 GZX4 50 MR11 20 60,117 20 12 G4 350 2000 T3 40 58 Projector 20 12 G4 350 2000 T3 40 58 Projector 30 12 PG22 800 50 T3 30 64261 Projector 30 12 G6.35 750 50 T3.
072_DOH_print.qxd 12/12/07 Med 2-pin 2:58 PM A21, A23 Page 215 GZ9.5 Bi-Pin P28s P40s PAR36 R7s, RX7s G22 Med Bi-pin AUDIOVISUAL 11 ANSI Code Product Number Ordering Abbreviation Application Watts Volts Base 76302 70335 BULK Special Purpose 27 6 Special 54793 JCP 650W/100V Overhead projection, 650 fiber-optic, entertainment 100 GY9.
072_DOH_print.qxd 12/12/07 Med Bi-pin 2:58 PM R7s, RX7s Page 216 GZ9.5 Bi-Pin G22 Med 2-pin STUDIO,THEATRE, TV & VIDEO 11c D I S P L A Y O P T I C H A L O G E N Lumens Avg Rated Life(hrs) Bulb Pkg Qty G9.5 10600 2000 T4 12 120 G9.5 20400 300 T5 12 120 G9.5 15400 2000 T5 12 300 120 R7s 5000 2500 T4 12 400 120 R7s 7500 2000 T4 12 3200 750 120 R7s 20600 400 T3 12 60 3200 420 120 GZ9.
072_DOH_print.qxd Med Bi-pin 12/12/07 2:58 PM Bi-Pin Page 217 S11 S14 R7s, RX7s PAR36 A21, A23 HPL G22 STUDIO,THEATRE, TV & VIDEO 11c Lumens Avg Rated Life(hrs) G9.5 15500 115 G9.5 115 G9.
072_DOH_print.
072_DOH_print.
072_DOH_print.qxd 12/12/07 PAR46,64 2:58 PM Page 220 MR11, MR16 (leads) AIRCRAFT 13 Ordering Abbreviation Application Beam Type CBCP Avg Rated MOL Pkg Filament Life(hrs) (mm) Qty Footnotes Watts Bulb 250 PAR46 28 G53 15399 4551 Aircraft Taxiing VNSP 75000 CC-6 25 95.25 12 32 450 PAR46 28 G53 56229 Q4681 Aircraft Landing / Taxiway VNSP 310000 CC-6 50 63.5 27,32 600 PAR64 28 G53 14936 4559 Aircraft Landing / Taxiway VNSP 600000 CC-8 25 101.
072_DOH_print.qxd 12/12/07 PK30d 2:58 PM Page 221 MR11, MR16 (leads) Med 2-pin AIRFIELD 14 Base Product Number Ordering Abbreviation Application Avg Current Rated LCL MOL Pkg (A) Lumens Filament Life(hrs) (mm) (mm) Qty Footnotes Watts Bulb 48 MR16 Leads-B 58906 6.6A/48MR16/64337B LL IRC Airfield/Airport 6.6 3000 45.6 Leads-C 58952 6.6A/48MR16/64337C LL IRC Airfield/Airport 6.6 3000 62 MR16 Leads-A 58493 6.6A/62W/MR16/64336A Airfield/Airport 6.
071_DO_drop.qxd 12/13/07 3:25 PM Page 222 4ArXS (For Architainment eXtreme Seal) Innovative metal halide lamps for creative architectural and effect lighting 4 ArXS HSD® 4ArXS HSD are new powerful metal halide lamps from OSRAM with innovative eXtreme Seal technology. The 4ArXS opens up new prospects for creative architectural and effect lighting. D I S P L A Y O P T I C D I S C H A R G E Optimized lamp seal technology to withstand interior base temperatures up to 450 °C.
071_DO_drop.qxd 12/13/07 3:25 PM Page 223 SharXS® HTI® from OSRAM The original light with a bite The SharXS (Short arc eXtreme Seal) HTI family uses state-of-the-art HTI technology to achieve a particularly high luminous efficacy. The arc in these innovative light sources has been reduced to 3-7mm. What this means for you is the SharXS HTI produces a higher luminance from the same wattage and therefore saves electricity and reduces operating costs.
071_DO_drop.qxd 12/13/07 3:25 PM Page 224 NOTES: r D I S P L A Y O P T I C D I S C H A R G E For more complete product information visit www.sylvania.
071_DOD_print.qxd 12/12/07 3:02 PM Page 225 HMI® METAL HALIDE 1 2 3 4 HMI® SINGLE-ENDED Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HMI 200 W/SE 54061 200 70 3.0 >90 16000 6000 80 39 20 5 200 Any GZY9.5 Yes 1 1 HMI 250 W/SE 54062 270 50 5.0 >90 16200 6000 84 35 12 5 250 p 45 FaX1.
071_DOD_print.qxd 12/12/07 3:02 PM Page 226 HMI® METAL HALIDE 1 2 HMI® SINGLE-ENDED D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HMI 2500 W/SE XS 54070 2500 115 25.
071_DOD_print.qxd 12/12/07 3:02 PM Page 227 HMI® METAL HALIDE 1 2 3 4 HMI® DOUBLE-ENDED Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l1 max (mm) Length l2 max (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HMI 575 W/DXS 54313 575 95 7.0 >90 49000 6000 135 115 21 7 1000 Any SFc10-4 Yes 1 55,90,161 HMI 575 W/GS 54098 575 95 7.
071_DOD_print.qxd 12/12/07 3:02 PM Page 228 HMI® METAL HALIDE 2 HMI® DOUBLE-ENDED D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l1 max (mm) Length l2 max (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HMI 6000 W 54073 6000 123 55.0 >90 570000 6000 450 HMI 6000 W/DXS 54315 6000 123 55.
071_DOD_print.qxd 12/12/07 3:02 PM Page 229 HTI® METAL HALIDE 1 2 3 4 5 6 7 HTI® SINGLE-ENDED Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l max (mm) Distance a (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HTI S 35/12 69000 35 85 2.5 >90 3200 6500 4250 79.5 27.1 4.2 3000 p 10 P32d-2 Yes 1 60 HTI 150 W 54078 150 90 1.
071_DOD_print.qxd 12/12/07 3:02 PM Page 230 HTI® METAL HALIDE 1 HTI® SHARXS® DOUBLE-ENDED D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HTI 400W/D3/75 SHARXS 54241 400 49 8.5 >80 26000 55000 7500 136 57.
071_DOD_print.qxd 12/12/07 3:02 PM Page 231 HTI® METAL HALIDE 1 HTI® SHARXS® DOUBLE-ENDED Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HTI 700W/D4/75 SHARXS 54242 700 70 10.0/11.0 >80 59000 60000 7500 136 57.5 20.
071_DOD_print.qxd 12/12/07 3:02 PM Page 232 HTI® METAL HALIDE 1 HTI® BABY SHARXS® DOUBLE-ENDED D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HTI 250W/D5/80 BABY SHARXS 54297 250 90 3.
071_DOD_print.qxd 12/12/07 3:02 PM Page 233 HTI® METAL HALIDE 1 2 3 D I S P L A Y O P T I C D I S C H A R G E HTI® DOUBLE-ENDED - OTHER Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HTI 300 W/DX 54143 300 100 3.6 90 22000 20000 6500 92 70 16 5.
071_DOD_print.qxd 12/12/07 3:02 PM Page 234 HTI® METAL HALIDE 1 D I S P L A Y O P T I C D I S C H A R G E 2 HTI® WITH DICHROIC REFLECTOR Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Color Temp (K) Length l max (mm) Working Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Hot Restart Fig No Symbols & Footnotes HTI 250 W/22 54080 270 45 6.0 70 5600 73 22 67 2.
071_DOD_print.qxd 12/12/07 3:02 PM Page 235 HSR® METAL HALIDE 1 2 D I S P L A Y O P T I C D I S C H A R G E HSR® WITH OUTER JACKET Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l max (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HSR 400/60 54102 400 67 6.9 >85 33000 20000 6000 110 62 23 5 650 Any GX9.
071_DOD_print.qxd 12/12/07 3:02 PM Page 236 HSD® METAL HALIDE 1 2 3 HSD® 4ARXS METAL HALIDE D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) CRI Lumens (lm) Color Temp (K) Length l (mm) Distance a (mm) Diameter d (mm) Electrode Gap - cold (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes HSD 150W/70 4ARXS 54311 150 97 1.8 >85 12000 7000 105 56 20 5.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.
071_DOD_print.qxd 12/12/07 3:03 PM Page 255 HBO® MERCURY SHORT ARC 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Lumens (lm) Luminous Intensity (cd) Average Luminance (cd/cm2) Luminous Area – w x h (mm) Luminous Efficacy (lm/W) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 HBO R 103 W/45 69311 100 23 DC 4.3 81.
071_DOD_print.
071_DOD_print.qxd 12/12/07 3:03 PM Page 257 HXP® MERCURY SHORT ARC 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Lumens (lm) Color Temp (K) Length l max (mm) Diameter d (mm) Working Distance A (mm) Avg Rated Life (hrs) Hot Restart Operating Position Base Fig No Symbols & Footnotes 2 HXP R 120 W/17C 69125 120 75 AC 1.4 4400 HXP R 120 W/45 C UV 69120 120 75 AC 1.4 77 56 17.
071_DOD_print.qxd 12/12/07 3:03 PM Page 258 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 4 5 HBO 200 W/DN-I 69136 200 25 DC 8.
071_DOD_print.qxd 12/12/07 3:03 PM Page 259 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 HBO 350 W 69226 350 68 DC 5.3 4600 128 102 45 20 2.
071_DOD_print.qxd 12/12/07 3:03 PM Page 260 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 HBO 1000 W/CEL 69175 750 47 DC 16.
071_DOD_print.qxd 12/12/07 3:03 PM Page 261 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 3 HBO 1003 W/PI 69195 750 26 DC 27.1 HBO 1003 W/PIL 69180 750 26 DC 25.8 197 169.
071_DOD_print.qxd 12/12/07 3:03 PM Page 262 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 HBO 1500 W/PI 69319 1500 23 DC 65.
071_DOD_print.qxd 12/12/07 3:03 PM Page 263 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 3 4 HBO 2001 W/NIL 69292 1750 26 DC 67.0 HBO 2002 W/NIL 69287 1750 24 DC 67.
071_DOD_print.qxd 12/12/07 3:03 PM Page 264 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 4 5 HBO 2002 W/MAL 69121 2000 40 DC 50.
071_DOD_print.qxd 12/12/07 3:03 PM Page 265 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 3 HBO 2700 W/CIL 69344 2700 24 DC 110.
071_DOD_print.qxd 12/12/07 3:03 PM Page 266 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 4 HBO 3501 W/PIL 69165 3400 23 DC 148.
071_DOD_print.qxd 12/12/07 3:03 PM Page 267 HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY 1 Ordering Abbreviation Product Number Watts (W) Volts (V) Type of Current Current (A) Radiant Intensity 350..450 nm (mW/sr) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Electrode Gap -- cold (mm) Avg Rated Life (hrs) Operating Position Cooling Base Anode Base Cathode Fig No Symbols & Footnotes 2 HBO 5500 W/PI 69164 5000 25 DC 200.0 355 154 85 5.
071_DOD_print.qxd 12/12/07 3:03 PM Page 268 VIP® VIDEO AND DATA PROJECTION 1 D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Volts (V) Current (A) Lumens (lm) Average Luminance (cd/cm2) Color Temp (K) Length l (mm) Distance a (mm) Diameter d (mm) Arc Length (mm) Avg Rated Life (hrs) Operating Position Base Hot Restart Fig No Symbols & Footnotes VIP R 273/45 69327 270 38 7.1 17000 100000 5800 73 45 67 1.
071_DOD_print.qxd 12/12/07 3:03 PM Page 269 SPECTRAL 1 Ordering Abbreviation Product Number Elements Watts (W) Volts (V) Current (A) Type of Current Operating Position Base Fig No Symbols & Footnotes 2 Na 10 FL 69284 Sodium 9 16 0.57 AC Vertical, base down Pico 9 1 119,128 For more complete product information visit www.sylvania.com D I S P L A Y O P T I C D I S C H A R G E Na/10 69282 Sodium 15 15 1.
071_DOD_print.qxd 12/12/07 3:03 PM Page 270 EXCIMER LAMPS 2 1 3 XERADEX® D I S P L A Y O P T I C D I S C H A R G E Ordering Abbreviation Product Number Watts (W) Length l1 max (mm) Length l2 max (mm) Distance a (mm) Diameter d (mm) Avg Rated Life (hrs) Operating Position Fig No Symbols & Footnotes XERADEX 20 69338 20 245 120 75 40 1500 Any 1 115,118,145,147 XERADEX 20/HV 69352 20 245 120 75 40 1500 Any 1 115,118,145,158 LX40T3/956/A3 52079 40 2000 Special 80000 T3 Coated Yes 350 15 391.
071_DO_drop.qxd 12/13/07 3:25 PM Page 271 LAMP BASES BA15d IEC 7004-11 DIN 49721 DL Bayonet FaX1.5-3x1 GY6.35-15 IEC 7004-59 2-pin BA15s IEC 7004-11A DIN 49720 SC Bayonet G4 IEC 7004-72 DIN 49757 2-pin BA20d IEC 7004-12 DIN 49730 GX5.3 IEC 7004-61 DIN 49640 2-pin GZ6.35 IEC 7004-59 A DIN 49754 2-pin For more complete product information visit www.sylvania.com GZX9.5 GZZ9.
071_DO_drop.qxd 12/13/07 3:25 PM Page 272 LAMP BASES GX16d 2-pin D I S P L A Y O P T I C R E F E R E N C E G38 IEC 7004-76 MOGUL Bipost GY16 DIN 49758 IEC 7004-45 2-pin GX38q GY17q DIN 49758 IEC 7004-74 4-pin K24s Length of cable 250 mm Hole of cable lug ø 8.4 mm DIN 49748 P40s DIN 49728 IEC 7004-43 medium pre-focus GY17t DIN 49665 IEC 7004-45 4-pin G22 IEC 7004-75 medium Bipost Pico9 DIN 41539 GY22 2-pin PG22-6.35 DIN 49751 IEC 7004-48 P28s DIN 49728 IEC 7004-42 MOGUL pre-focus .
071_DO_drop.qxd 12/13/07 3:25 PM Page 273 LAMP BASES SFcX27-8 (5/16-18UNC-2 A) SK27-50 SFa5-2 SFa6-2 SFa7.5-2 SFa8-2 SFa9-2 SFa12-11 SFa21-5 SFa15-10 SFa16-8 SFa16-10 SFa20-8 SFa20-10 SFa25-10 SFa27-8 SFa27-10 SFa27-11 SFa27-12 SFa27-14 SFa28-18 SFcX12-4 (with M4 thread and centering collar) SFa21-12 DIN 49759 SFc10-4 M4-thread SFc6-3 M3-thread SFc12-4 M4-thread SFc13-4 M4-thread SFaX27-10 SFaX27-9.5 SFaX27-12 SFaX27-13 SFaX27-14 SFaX30-9.5 SFaX30-16 SX15s SFc25-14 (M 14x1.
071_DO_drop.qxd 12/13/07 3:25 PM Page 274 OPERATING POSITIONS Schematic diagrams D I S P L A Y O P T I C R E F E R E N C E permitted not permitted GENERAL INFORMATION In North America, OSRAM brand Display/Optic lighting products are sold by OSRAM SYLVANIA AND OSRAM SYLVANIA LTD. Sales are subject to standard terms and conditions of sale prevailing as of the date of purchase. Operational data and dimensions are nominal values. OSRAM reserves the right to make technical modifications without notice.
071_DO_drop.qxd 12/13/07 3:25 PM Page 275 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS Symbol Description New item introduced within the past year. Item will be discontinued when inventory is depleted. Footnote Description 1 Type of current: square-wave AC. 2 Lamp arc needs to be in horizontal operating position. 3 Any operating position allowed with appropriate cooling.
071_DO_drop.qxd 12/13/07 3:25 PM Page 276 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS D I S P L A Y O P T I C R E F E R E N C E Footnote Description 45 H=Suitable for horizontal operation 46 TC=Thread and Cable 47 CA=Cable on anode base 48 All HTI« lamps are hot restrikeable with the exception of HTI 150, HTI 152, HTI 405 W/SE, and 705 W/SE.
071_DO_drop.qxd 12/13/07 3:25 PM Page 277 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS Footnote Description 91 Photometric data refer to discharge tube (lamp burner). 92 Lamp also available with 850 hrs (HBO 3500 W/PI, Product Number 69174) 93 Lamp also available with 850 hrs (HBO 3501 W/PI, Product Number 69127) 94 Lamp also available as Longlife version HBO 2500 W/PIL with 1500hr life (Product Number 69172).
071_DO_drop.qxd 12/13/07 3:25 PM Page 278 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS D I S P L A Y O P T I C R E F E R E N C E Footnote Description 135 Lamp life may vary depending on duty cycle and application. 136 Connector = Female. 137 Connector = Male. 138 Snap-on connector, female / male contact. 139 In horizontal operation position it is recommended that the "lead connection" wire be in the top position with filler tip facing down.
071_DO_drop.qxd 12/13/07 3:25 PM Page 279 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS Footnote Description 176 Beam Angle data refers to aperture. 177 Lamp is suited for use in ASML equipment (PAS 5500/22, /100, /100B, /TFH100). 178 The QXL lamp allows easy one-hand replacement without opening the light fixture. 1/4 turn twist in/out, no tool required. 179 With vertical operating position: anode(+) on top. 180 QXL is a trademark of Electronics Theatre Controls Inc.
071_DO_drop.qxd 12/13/07 3:25 PM Page 280 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS D I S P L A Y O P T I C R E F E R E N C E Footnote Description 224 HBO 200W/2 and HBO 500W/2 can be operated on AC or DC. 225 Lamp also available with increased radiation in the wavelength range below 450nm for UV-curing. HBO 202W/4 (Product Number 69316). 226 Lamp also available with threaded pin 8-32 UNC-3A: HBO 200 W/2TM (Product Number 69223).
071_DO_drop.qxd 12/13/07 3:25 PM Page 281 SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS Footnote Description 272 Despite transverse filament, lamp can be inclined at any angle in s 90 position. 273 Lamp has snap-on male contact to DIN 46248. 274 Lamp also available with male contact according to DIN 46248. 64361/HLX Z (Product Number 58717) 275 Lamp has D.C. Bay Ring. 276 WARNING: Lamp only for use where seal temperature does not exceed 650 degrees F (343 degrees C).
071_DO_drop.qxd 12/13/07 Index by Ordering Abreviation Type D I S P L A Y O P T I C I N D E X 3:25 PM Page 282 Type Page 111A . . . . . . . . . . . . . . . . . . . . . . . .217 140 . . . . . . . . . . . . . . . . . . . . . . . . . .217 211 118V . . . . . . . . . . . . . . . . . . . . .217 212 118V . . . . . . . . . . . . . . . . . . . . .217 4551 . . . . . . . . . . . . . . . . . . . . . . . . .220 4557 . . . . . . . . . . . . . . . . . . . . . . . . .220 4559 . . . . . . . . . . . . . . . . . . . .
071_DO_drop.qxd 12/13/07 3:25 PM Index by Ordering Abreviation (cont.) Type Page 283 Type Page HMI 18000 W/SE/GX51 . . . . . . . . . .226 HPL 375/115 (UCF) . . . . . . . . . . . . .217 HPL 375/115/X (UCF) . . . . . . . . . . .217 HPL 550/77 (UCF) . . . . . . . . . . . . . .217 HPL 550/77/X (UCF) . . . . . . . . . . . .217 HPL 575/115 (UCF) . . . . . . . . . . . . .217 HPL 575/115/X (UCF) . . . . . . . . . . .217 HPL 575/120 (UCF) . . . . . . . . . . . . .217 HPL 575/120/X (UCF) . . . . . . . . . . .
071_DO_drop.qxd 12/13/07 Index by Product Number (continued) Type D I S P L A Y O P T I C I N D E X Page 54430 . . . . . . . . . . . . . . . . . . . . . . . .213 54435 . . . . . . . . . . . . . . . . . . . . . . . .216 54436 . . . . . . . . . . . . . . . . . . . . . . . .216 54441 . . . . . . . . . . . . . . . . . . . . . . . .216 54442 . . . . . . . . . . . . . . . . . . . . . . . .216 54446 . . . . . . . . . . . . . . . . . . . . . . . .213 54448 . . . . . . . . . . . . . . . . . . . . . . . .
071_DO_drop.qxd 12/13/07 3:25 PM Index by Product Number (continued) Type Page 285 Index by ANSI Code Type Type Page Page ENL . . . . . . . . . . . . . . . . . . . . . . . . .212 ENX . . . . . . . . . . . . . . . . . . . . . . . . .212 Page BAA . . . . . . . . . . . . . . . . . . . . . . . . .211 ENX-5 . . . . . . . . . . . . . . . . . . . . . . . .212 BBA . . . . . . . . . . . . . . . . . . . . . . . . .211 69461 . . . . . . . . . . . . . . . . . . . . . . . .252 69462 . . . . . . . . . . . . . . .
071_DO_drop.qxd 12/13/07 3:25 PM Page 286 WARNING TUNGSTEN HALOGEN & INCANDESCENT DISPLAY/OPTIC LAMPS The following information pertains to all Display/Optic Tungsten-Halogen and Incandescent lamps including Infrared Heat Lamps, Current-Controlled Airfield Lamps, PAR and other Reflector Lamps. WARNING: In accordance with ANSI/IESNA Standard RP-27, Display/Optic incandescent & tungsten halogen lamps are Risk Group 2 products.
071_DO_drop.qxd 12/13/07 3:25 PM Page 287 TUNGSTEN HALOGEN & INCANDESCENT DISPLAY/OPTIC LAMPS (continued) LAMP DIMMING: 1. Incandescent lamps (non-halogen): Incandescent lamps perform according to fixed relationships between luminous flux, luminous efficacy, color temperature, electrical voltage, electrical current and electrical power consumption.
071_DO_drop.qxd 12/13/07 3:25 PM Page 288 ® ® ® ® ® ® ® METAL HALIDE DISPLAY/OPTIC LAMPS [HCD , HMI , HMD , HMP , HSD , HSR , HTI ] (continued) INSTALLATION: 1. Do not use if lamp is scratched, cracked or damaged in any way. 2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp. 3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands. Use clean gloves. 4.
071_DO_drop.qxd 12/13/07 3:25 PM Page 289 ® ® ® ® ® ® ® METAL HALIDE DISPLAY/OPTIC LAMPS [HCD , HMI , HMD , HMP , HSD , HSR , HTI ] (continued) LAMP TRANSPORTATION: 1. All Display/Optic metal halide lamps should be transported ONLY in their original packaging. 2. Transportation in non-original packaging can damage the lamp and void warranty. 3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLY in DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
071_DO_drop.qxd 12/13/07 3:25 PM Page 290 VIP SUPER HIGH PRESSURE MERCURY LAMPS (DISPLAY/OPTIC) (continued) BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL): 1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor.
071_DO_drop.qxd 12/13/07 3:25 PM Page 291 ® VIP SUPER HIGH PRESSURE MERCURY LAMPS (DISPLAY/OPTIC) (continued) • Concentration in air: 13.6 mg/m3 @ 20°C / 68°F 29.6 mg/m3 @ 30°C / 86°F 62.7 mg/m3 @ 40°C / 104°F • CAS Registry Number: 7439-97-6 • RCRA waste number: U151 • Other Names: Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver LAMP DISPOSAL: 1.
071_DO_drop.qxd 12/13/07 3:25 PM Page 292 XBO® HIGH PRESSURE XENON LAMPS (continued) 17. When installing bare lamps that have an included flat washer, slip the washer over the threaded pin on the cathode (- negative) side. Removal of this flat washer (after half the average life) will allow a rotation of the lamp by 180° resulting in better output maintenance over life for horizontally operated lamps. This should be done only if darkening is evident in the upper part of the bulb.
071_DO_drop.qxd 12/13/07 3:25 PM Page 293 WARNING HBO® HIGH PRESSURE MERCURY LAMPS WARNING: In accordance with ANSI/IESNA Standard RP-27, this HBO bulb is a Risk Group 3 product. Read and understand this warning before using this bulb! RUPTURE & RADIATION (UV- VISIBLE) HAZARD: 1. The discharge vessel of HBO lamps is constructed of quartz glass that is filled with a quantity of mercury and either Argon or Xenon gas.
071_DO_drop.qxd 12/13/07 3:25 PM Page 294 HBO® HIGH PRESSURE MERCURY LAMPS (continued) OPERATING POSITION: HBO lamps may only be operated in the operating positions described in the OSRAM SYLVANIA product catalog. Some HBO lamps are designed to operate horizontally (mainly low wattage types in the power range of 50 to 200 W) and others, vertically (all lamp types withpower consumption of 350 W and higher).
071_DO_drop.qxd 12/13/07 3:25 PM Page 295 HBO® HIGH PRESSURE MERCURY LAMPS (continued) PROPERTIES OF MERCURY: • Chemical symbol: • Atomic number: • Molecular Weight: • Density: • Melting Point: • Boiling Point: • Vapor pressure: • Concentration in air: • • • CAS Registry Number: RCRA waste number: Other Names: Hg 80 200.59 13.6 g/cm3 @ 20°C / 68°F -39°C / -38.2°F 357°C / 674°F 160 Pa @ 20°C / 68°F 370 Pa @ 30°C / 86°F 823 Pa @ 40°C / 104°F 13.6 mg/m3 @ 20°C / 68°F 29.6 mg/m3 @ 30°C / 86°F 62.
071_DO_drop.qxd 12/13/07 3:25 PM Page 296 NOTES: D I S P L A Y O P T I C R E F E R E N C E For more complete product information visit www.sylvania.
080_LED.qxd 12/12/07 4:04 PM Page 297 LED SYSTEMS The most important trend in lighting technology is the move towards systems… we started this trend with THE SYSTEM SOLUTION®, a family of optimally balanced energy saving lamps and ballast combinations. We are now extending that trend with LED systems for the lighting market.
080_LED.qxd 12/12/07 4:04 PM Page 298 LED SYSTEMS CONTINUED… LINEARlight Systems Flexible LINEARlight reels are available with TOPLED or SIDELED options and in a variety of colors. The LINEARlight MULTIFLEX provides new dimensions for innovative lighting. POWERFLEX LINEARlight modules offer superior lumen output for white light. The LINEARlight modules are mounted on rigid boards which make them an ideal choice for small and sleek luminaires. Optics and connectors are available for the rigid modules.
080_LED.qxd 12/12/07 4:04 PM Page 299 Safety Information for all LED modules and accessories WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES.
080_LED.qxd 12/12/07 4:04 PM Page 300 SPOT/FLOOD PRODUCTS HF2Eye Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Display case lighting, Vehicle cabin lighting, Solar powered installations | Product | Number | Color Wavelength /(CCT ˚K) OPTOTRONIC Power Supply Current (Amps) Load Wattage Beam Angle (Degrees) Luminous Intensity 264 White 3300K Constant Current .35 1.2 15 230 264 White 5400K Constant Current .35 1.
080_LED.qxd 12/12/07 4:04 PM Page 301 HFDisk Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Display case lighting, Vehicle cabin lighting, Solar powered installations | Product | Number | Ordering Description Pkg Case Qty Qty 70203 HFDisk/3/W2-733 10 70204 HFDisk/3/W2-847 10 Load Current (Amps) | | | Viewing Load Angle Wattage (Degrees) Lumens Color Wavelength /(CCT ˚K) LEDs/ Module OPTOTRONIC Power Supply 100 White 3300K 3 Constant Current .35 3.
080_LED.qxd 12/12/07 4:04 PM Page 302 HF2Flood Down lighting, Accent lighting, Cove lighting, Outdoor and landscape lighting, Vehicle cabin lighting, Solar powered installations | Product | Number | Color Wavelength /(CCT ˚K) OPTOTRONIC Power Supply Current (Amps) Load Wattage Radiance Angle (Degrees) Luminous Intensity 20 White 3300K 24 Vdc .50 12 25 700 20 White 4700K 24 Vdc .50 12 25 700 1 20 White 5400K 24 Vdc .50 12 25 700 1 20 White 6500K 24 Vdc .
080_LED.qxd 12/12/07 4:04 PM Page 303 HF2Stick XB Shelf lighting, Under cabinet lighting, Refrigerator and freezer case lighting, Cove lighting, Display lighting, Street lighting | Product | Number | Color Wavelength /(CCT ˚K) LEDs/ Module OPTOTRONIC Power Supply Load Current (Amps) Viewing Luminous Load Angle Flux Wattage (Degrees) (Lumens) Lumens /foot 50 White 2700K 4 24 Vdc 0.23 5.6 100 130 135 50 White 4100K 4 24 Vdc 0.23 5.6 100 150 156 50 White 6500K 4 24 Vdc 0.
080_LED.qxd 12/12/07 4:04 PM Page 304 LINEARlight Flex Top Colormix Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications | Product | Number | 70229 Ordering Description Pkg Qty Case Qty LNRFLXTPLM10LB8RGB213.1FT 1 8 Red Channel Wavelength /(CCT ˚K) Load Viewing Luminous LEDs/ OPTOTRONIC Current Load Angle Flux Lumens Module Power Supply (Amps) Wattage (Degrees)(Lumens) /foot 625nm 200 24 Vdc 0.5 12.1 120 385 | | | 29.
080_LED.qxd 12/12/07 4:04 PM Page 305 LINEARlight Escape route marker, Border marker, Walkways, Outlines | Product | Number | Color Wavelength /(CCT ˚K) LEDs/ Module OPTOTRONIC Power Supply Load Current (Amps) Viewing Luminous Load Angle Flux Wattage (Degrees) (Lumens) Lumens /foot 10 Super Red 633nm 32 10 Vdc 0.4 4.2 120 54 37 10 Amber Red 617nm 32 10 Vdc 0.4 4.2 120 86 59 1 10 Orange 606nm 32 10 Vdc 0.4 4.2 120 98 67 1 10 Yellow 587nm 32 10 Vdc 0.4 4.
080_LED.
080_LED.qxd 12/12/07 4:04 PM Page 307 DRAGONtape Task lighting.
080_LED.qxd 12/12/07 4:04 PM Page 308 BACKlight 2G BLO2 Backlighting advertising panels, Signs, Channel letters and displays, General lighting | Product | Number | Color Wavelength /(CCT ˚K) LEDs/ Module OPTOTRONIC Power Supply Load Current (Amps) Viewing Luminous Load Angle Flux Wattage (Degrees) (Lumens) Lumens /foot 5 Super Red 633nm 240 10 Vdc 3.6 38 120 490 16 5 Amber Red 617nm 240 10 Vdc 3.6 38 120 1180 37.5 1 5 Orange 606nm 240 10 Vdc 3.
080_LED.qxd 12/12/07 4:04 PM Page 309 BACKlight Backlighting advertising panels, Signs, Channel letters and displays, General lighting | Product | Number | Color Wavelength /(CCT ˚K) LEDs/ Module OPTOTRONIC Power Supply Load Current (Amps) Viewing Luminous Load Angle Flux Wattage (Degrees) (Lumens) Lumens /foot 20 Super Red 633nm 32 10.5 Vdc 0.4 4.2 120 54 30 20 Amber Red 617nm 32 10.5 Vdc 0.4 4.2 120 54 30 1 20 Orange 606nm 32 10.5 Vdc 0.4 4.
080_LED.qxd 12/12/07 4:04 PM Page 310 ACCESSORIES FOR SPOT/FLOOD PRODUCTS Spot/Flood Thermal Management Solutions Thermal management solutions for DRAGONpuck® and HFDisk modules | Product Number | Ordering Description Pkg Qty Case Qty Diameter (in.) Height (in.) 70136 Heatsink/DRAGONpuck-50 1 50 3.5 0.
080_LED.qxd 12/12/07 4:04 PM Page 311 HF2Stick XB Connector Accessory to HF2Stick XB modules | Product Number | Ordering Description Pkg Qty Case Qty Length in (mm) Width in (mm) Height in (mm) Wire Length in (mm) 70197 HF2StickXB Connector/input conn 10 500 .57 (14.5) .28 (7) .34 (8.7 12 (305) 70196 HF2StickXB Connector/conn 10 500 .57 (14.5) .28 (7) .34 (8.7) 1.77 (45) 70195 HF2StickXB Connector/conn-12 10 500 .57 (14.5) .28 (7) .34 (8.7) 11.
080_LED.qxd 12/12/07 4:04 PM Page 312 LINEARlight Optics Accessory to LINEARlight modules | Product Number | Ordering Description Pkg Qty Case Qty Length in (mm) Width in (mm) Viewing Angle (Degrees) 70072 LINEARLT Optics OS-OP4X1-20 + OS-LM01A 1 80 2.20(56) 0.
080_LED.qxd 12/12/07 4:04 PM Page 313 LINEARlight FLEX Connectors Compatible with LINEARlight POWERFLEX, LINEARlight Flex TOPLED, and LINEARlight FLEXSIDE LED | Product Number | Ordering Description Pkg Qty Case Qty Length in (mm) Width in (mm) Height in (mm) Wire Length in (mm) 70269 LM2PINFLEXCONN 10 1000 0.48 (12.25) 0.65 (16.5) 0.2 (5) 19.69 (500) 70263 LM2CONN5FLEXCONNBB 10 2000 1.4 (34.5) 0.65 (16.5) 0.2 (5) 0.
088_LUM_LETR.qxd 12/12/07 4:08 PM Page 314 CONSUMER LUMINAIRES SYLVANIA Consumer Luminaires offer consumer and professional products to both new and existing markets that incorporate advanced, innovative LED technology. The consumer luminaires product portfolio includes: SYLVANIA Bright White LED light™ Meet the bright, long-lasting light that you can stick practically anywhere—over and over. DOT-it bright white LED lights outperform incandescent tap lights in brightness and life.
088_LUM_LETR.qxd 12/12/07 4:08 PM Page 315 LED RETROFIT LAMPS LED Retrofit Lamps fill the niche for LED replacements for traditional incandescent or halogen S14, PAR20 and MR16 lamps. LED technology offers substantially better improved energy savings and exceptionally long life. They are ideal where temperature extremes and difficult or hard-to-reach locations are a factor with conventional light sources.
090_Warr.qxd 12/12/07 4:09 PM Page 316 SYLVANIA HID SYSTEM LIMITED WARRANTY Combination Lamp and Ballast System Limited Warranty OSRAM SYLVANIA Products Inc. (“OSPI”) warrants SYLVANIA lamps installed on SYLVANIA magnetic ballasts to be free from defects in material and workmanship and to operate from the date of installation (or 3 months from date of manufacture if installation date is not known or available) for the lamp and ballast warranty System METALARC® METALARC® LUMALUX® LUMALUX® Avg.
090_Warr.qxd 12/12/07 4:09 PM Page 317 The Heart of a Comprehensive System Service Program QUICK 60+® Limited Warranty Subject to change without notice. Compare lighting system warranties – you’ll see that our QUICK 60+ warranty offers better coverage, more service options and, more important, peace of mind. Combination Lamp and Ballast System Limited Warranty OSRAM SYLVANIA Products Inc.
090_Warr.qxd 12/12/07 4:09 PM Page 318 QUICK 60+® LIMITED WARRANTY Registration Form Subject to change without notice. Photocopy the form below and use it to register any installation featuring QUICKTRONIC® ballast systems. Also available, is our on-line version which you may find by visiting our web site at www.sylvania.com. The warranty coverage begins from the date of installation, but you must register an installation in order to receive warranty service.
090_Warr.qxd 12/12/07 4:09 PM Page 319 Magnetic Ballast Limited Warranty OSRAM SYLVANIA Products Inc. (“OS”) warrants SYLVANIA fluorescent magnetic ballasts and high intensity discharge (HID) magnetic ballasts to be free from defects in material and workmanship and to Magnetic Ballast Type Fluorescent Magnetic High Intensity Discharge (HID) Magnetic Magnetic Sign operate from the date of manufacture for the time periods specified below.
090_Warr.qxd 12/12/07 4:09 PM Page 320 OSRAM SYLVANIA Products, Inc. (OSI) is pleased to provide the following warranty for the periods shown below. This warranty covers OSI’s LED Modules and Optotronic® Power supplies or controls when installed as a system.
090_Warr.qxd 12/12/07 4:09 PM Page 321 LIMITED PRODUCT WARRANTY HBO® SEMICONDUCTOR LAMPS OSRAM SYLVANIA INC. (OSI) warrants that its HBO OSRAM mercury short arc lamp (HBO Lamp) for microlithography will be in conformity with OSI published specifications and free from defects in material and workmanship.
110_index.qxd 12/18/07 12:55 PM Page 322 Index INCANDESCENT LAMPS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Lamp Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Bulb Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
110_index.qxd 12/18/07 12:55 PM Page 323 Index (continued) COMPACT FLUORESCENT LAMPS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 DULUX Lamp Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
110_index.qxd 12/18/07 12:55 PM Page 324 Index (continued) ELECTRONIC & MAGNETIC BALLASTS, LED POWER SUPPLIES TABLE OF CONTENTS ELECTRONIC BALLASTS . . . . . . . . . . . . . . . . . . . . . .173 The System Solution and Product Families . . . . . . . . . . . . . . . . . . . . . . .172-175 QUICKTRONIC Electronic Fluorescent, CFL & HID Ballasts . . . . . . . . . .176-184 LED Power Supplies & Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
110_index.qxd 12/18/07 12:55 PM Page 325 Index (continued) CONSUMER LUMINAIRES Introduction & Product Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314 LED RETROFIT LAMPS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315 PAR20 Retrofit Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315 S14 Retrofit Lamps . . . . . . . . . . . . . . . . . . . . . . . . . .
110_index.qxd 12/18/07 12:55 PM Page 326 Notes: I N D E X For more complete product information visit www.sylvania.
www.sylvania.com Note: OSRAM SYLVANIA LTD.