SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
New item introduced within the past year.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
Footnote Description
1 Consult your OSRAM SYLVANIA Lighting Representative for compatible electronic operating systems.
2 Use in equipment where gasket material is protected from all lamp radiation.
3 Use with 5000V pulse rated sockets only.
4 Use with 4000V pulse rated sockets only.
5 Unjacketed reprographical/photochemical lamp.
6 20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start.
7 Passes Federal TCLP test based on NEMA LL Series Standards. TCLP data available upon request. Disposal regulations may vary depending
on location. Please check your local and state/provincial regulations.
8 Voltage rise due to fixture effect is to be evaluated using standard lamp types and not LUMALUX PLUS lamp types
9 H34 and H36 lamps are not interchangeable.
10 Consult your OSRAM SYLVANIA Lighting Representative for lamp/ballast compatibility.
11 Horizontally oriented lamps require a position oriented mogul (POM) socket to accept position oriented mogul bases.
12 Operates at 360 watts on 400w M59 ballast or a M165 ballast.
13 55 Volt lamp.
14 100 Volt lamp.
15 UNALUX lamps must be operated on mercury lag or reactor ballasts only.
16 Lamps must be operated on CW/CWA ballasts only
17 O = Lamps classified as O-type, comply with ANSI standard C78.389 for containment testing and may be used in open luminaries. See lamp
warning.
18 E = Lamps classified as E-type are to be used ONLY in suitably enclosed luminaries. See lamp warning.
19 Standby feature not guaranteed beyond 24,000 operating hours.
20 S = When operated within 15 degrees of vertical, this lamp may be operated in an open luminaire provided the installation is not near people
or flammable or combustible material, otherwise it must be operated in a suitably enclosed luminaire. See lamp warning.
21 F = Enclosed luminaire with UV filter and lens interlock required. WARNING: This lamp emits ultraviolet radiation which can cause serious
skin burn and eye inflammation. Additionally, this lamp operates under high pressure at very high temperatures. Should the lamp break there
can exist a danger of personal injury and/or fire from the broken lamp particles being discharged. This lamp should only be used in fully
enclosed luminaire with ultraviolet (UV) filter tempered glass lens capable of containing any particles discharges by breakage. Do not use this
lamp if the filter lens is damaged or missing. This lamp should only be used in luminaires equipped with safety interlock lens switches. See
lamp warning.
22 Mean lumens measured at 50% of average rated life
23 When operated on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced.
24 The circuit must include overcurrent protection (I.e. Thermally switched ballast).
25 Lamp requires a nominal Open Circuit Voltage of 230V or higher. Without an igniter in the circuit minimum OCV is 209Vrms.
26 Lamps may be operated on ANSI M98 Compliant Ballast.
27 Lamps may be operated on ANSI M140 Compliant Ballast.
28 Published rated life based on 5 hours per start. Life rating will increase to 6,000 hours if operated for at least 10 hours per start in the base
up position. Lumens will be lower for operating positions other than base up. See lumen tilt factor curve in the Metal Halide Specification
Guide.
29 Operates at 150W on a 175W M57 ballast or a M107 ballast.
30 UV-Stop quartz
31 Lamps may be operated on a M142 Compliant ballast.