User Guide

HOW TO READ PRODUCT INFORMATION - COMPACT FLUORESCENT
Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Generic Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
(@35˚C/95˚F)
|
13 Twist 4.6 117 Med 29116 CF13EL/MINITWIST 6 8000 3000 82 800 640 2,21,28,
36,63,64
26 D(T4) 6.8 173 G24D-3 20710 CF26DD/830/ECO CFQ26W/G24D/30 50 10000 3000 82 1800 1548 2,21,28,
34,37
32 T(T4) 5.5 140 GX24Q-3 20885 CF32DT/E/IN/835/ECO CFTR32W/GX24Q/35 50 10000 3500 82 2328 2002 2,21,28,
2400 2064 33,35,59
40 L(T5) 22.6 573 2G11 20586 FT40DL/841/RS/ECO FT40W/2G11/RS/41 10 20000 4100 82 3150 2709 2,21,28
Nominal Wattage Design wattage on reference ballast. Actual wattage dependent on ballast.
Bulb Describes the shape of the bulb.
Base Base designations for compact fluorescent lamps are the NEMA designations. Please see page 111 for base illustrations.
MOL Maximum overall length. The actual length of the lamp measured from the bottom of the base to the top outside edge of the
glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp.
Symbols & Footnotes Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the fluorescent section.
Ordering Abbreviation A text description of the lamp. Please see below for several examples and explanations of some of the codes.
NEMA Generic Designation assigned by NEMA (National Electrical Manufacturers Association).
Designation
CCT Correlated Color Temperature. The degree of “whiteness” of the light. Expressed in kelvins (K).
Please see page 109 for more information.
CRI Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to
a standard. Please see page 109 for more information.
Initial & Mean Lumens Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at
40% of the rated life of the lamp. Compact Fluorescent lamp lumens are measured at 25°C (77°F) and 35˚C (95˚F)
How to Read Ordering Abbreviations
CF26DD/830 CF32DT/E/IN/835/ECO FT40DL/841/RS/ECO CF20EL/830/MED/ECO
CF Compact Fluorescent CF Compact Fluorescent FT Fluorescent Twin CF Compact Fluorescent
26 Nominal lamp wattage 32 Nominal lamp wattage 40 Nominal lamp wattage 20 Nominal lamp wattage
DD DULUX
®
Double DT DULUXTriple DL DULUX Long EL Electronic Lamp
8 82 CRI E Electronic or dimming 8 82 CRI 8 82 CRI
30 3000K CCT operation 41 4100K CCT 30 3000K CCT
IN Amalgam RS Rapid Start MED Medium screw base
8 82 CRI ECO ECOLOGIC ECO ECOLOGIC
35 3500K CCT
ECO ECOLOGIC
DULUX
®
LAMP FAMILIES
CF... DS = DULUX Single, 2-pin for magnetic operation, ECOLOGIC
®
CF... DS/E = DULUX Single, 4-pin for electronic or dimming operation
CF... DD = DULUX Double, 2-pin for magnetic operation, ECOLOGIC
CF... DD/E = DULUX Double, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT = DULUX Triple, 2-pin for magnetic operation, ECOLOGIC
CF... DT/E = DULUX Triple, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT/E/IN = DULUX Triple, 4-pin for electronic or dimming operation, amalgam, ECOLOGIC
FT... DL = Fluorescent Twin, DULUX Long, 4-pin
CF... DF = DULUX Flat, 4-pin
CF... EL = DULUX self-ballasted, medium screw base
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 124