164
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote Description
96 SAFELINE lamps satisfy the criteria of having a non-shattering covering for prevention of glass and other lamp components in your product
by containment within the safety coating material. The covering must be intact or the lamp must be replaced to be in compliance. An onsite
inspector will require correction if the lamps are installed improperly or not maintained properly.
97 Average life rating at 12 hours operation per start is 18,000 hours.
98 SAFELINE lamps are intended for indoor use only. Lamps must be used in ambient temperatures below 135 degreed F. The coating is
designed to withstand constant operating temperatures up to 239 degrees F and has a melting point in excess of 500 degrees F. Lamps must
be used with sockets that provide adequate lamp pin to socket contact. Lamps must not be used with defective ballasts sockets, or fixtures
with improper wiring.
99 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.25 meters (10 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
100 WARNING: ICETRONĀ® Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. 1. This lamp operates at a higher temperature (130 C) than standard fluorescent lamps. To avoid the possibility of minor skin
burns, do not touch lamp or metal mounting brackets during operation and allow sufficient cooling time prior to servicing, handling, or
replacing lamp. 2. This lamp generates electric and magnetic fields during operation. The electric and magnetic fields generated by this lamp
during operation in typical lighting applicatons do not pose exposure risks relative to the limits documented in ANSI C95.1. 3. To prevent
electric shock, shut off the main power to the fixture and allow at least two minutes for ballast voltage to discharge before attempting to serv-
ice or replace lamp. 4. To obtain optimum safety and system performance, use only with OSRAM SYLVANIA ballast. 5. To avoid potential
electric shock hazard, do not use lamp if wires or insulation are cut or pulled out of connector.
101 WARNING: ICETRONĀ® Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. Instructions for Installation and Use. 1) To avoid premature lamp or ballast failure and ensure proper lamp, ballast, and system
performance, make sure lamp, ballast, and fixture are properly installed. Electrical interconnects, electrical grounds, thermal management,
and heatsinking specifications and requirements must be fully adhered to in all applications. (See OSRAM SYLVANIA ICETRON DESIGN
GUIDE.) 2. Do not alter the electrical connector on lamp and/or ballast. To do so may adversely affect lamp operation, ballast life, and/or
emission of EMI (electromagnetic interference). 3. This product may cause interference with radios, cordless telephones, and remote control
devices. If interference occurs, relocate the radios, cordless telephones, and/or remote control devices away from this product.
102 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
103 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.35 meters (14 inches) should be limited; for example exposure at 0.25m (10 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
104 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.45 meters (18 inches) should be limited; for example exposure at 0.3m (12 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
105 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.55 meters (22 inches) should be limited; for example exposure at 0.4m (16 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
106 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.65 meters (26 inches) should be limited; for example exposure at 0.45m (18 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
107 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.7 meters (28 inches) should be limited; for example exposure at 0.54m (20 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd 12/12/07 3:40 PM Page 164