User Guide
51818 = QTP 1/2x13CF/UNV
120-277
13W DD/E,T/E 900 1 1.00 900 16 56
51850
=
QTP 1/2x13CF/UNV-KIT
L 0.25/0.11 13W DD/E,T/E 900 2 1.00 1800 29 62
51823
= QTP 1/2x18CF/UNV
120-277
18W DD/E,T/E 1200 1 1.00 1200 20 60
51851
=
QTP 1/2x18CF/UNV-KIT
L 0.32/0.14 18W DD/E,T/E 1200 2 1.00 2400 38 63
26W DD/E,T/E 1800 1 1.00 1800 28 64
51833
= QTP 2x26CF/UNV
120-277
0.50/0.22 26W DD/E,T/E 1800 2 1.00 3600 54 67
51852
=
QTP 2x26CF/UNV-KIT
L
32W DT/E 2400 1 0.98 2350 35 67
51898 QTP 2x26CF/UNV PEM
42W DT/E 3200 1 1.00 3200 45 71
26W DT/E 1800 2 1.02 3670 54 68
51843 QTP 2x26/32/42CF/UNV M 32W DT/E 2400 2 0.96 4600 69 67
51853
=
QTP 2x26/32/42CF/UNV M-KIT
L 120-277 0.90/0.40 42W DT/E 3200 2 0.95 6080 94 65
51863 QTP 2x26/32/42CF/UNV M PEM 0.53/0.23 57W DT/E 4300 1 1.00 4300 62 69
0.57/0.25 70W DT/E 5200 1 0.92 4780 71 67
Also operates: see Ballast Technology & Specification Guide for additional lamp types.
LCF Kits include a ballast, screws, wire, mounting bracket, an instruction sheet and a wire removal tool.
NORMAL BALLAST FACTOR -
QTP CF models above replace shaded item numbers below
51718 QTP 1/2x13CF/UNV BS
120-277
13W DD/E,T/E 900 1 1.00 900 16 56
51748 QTP 1/2x13CF/UNV TS 0.25/0.11 13W DD/E,T/E 900 2 1.00 1800 29 62
51723 QTP 1/2x18CF/UNV BS
120-277
18W DD/E,T/E 1200 1 1.00 1200 20 60
51753 QTP 1/2x18CF/UNV TS 0.32/0.14 18W DD/E,T/E 1200 2 1.00 2400 38 63
26W DD/E,T/E 1800 1 1.00 1800 28 64
51733 QTP 2x26CF/UNV BS
120-277
0.50/0.22 26W DD/E,T/E 1800 2 1.00 3600 54 67
51763 QTP 2x26CF/UNV TS 32W DT/E 2400 1 0.98 2350 35 67
42W DT/E 3200 1 1.00 3200 45 71
51738 QTP 1/2xCF/UNV BM 26W DD/E,T/E 1800 1 1.02 1830 28 65
51798 QTP 1/2xCF/UNV PM
120-277
0.57/0.25 26W DD/E,T/E 1800 2 1.02 3670 57 64
51768 QTP 1/2xCF/UNV TM 32W DT/E 2400 1 0.97 2330 36 65
42W DT/E 3200 1 1.00 3200 46 70
51743 QTP 2x26/32/42CF/UNV BM 26W DT/E 1800 2 1.02 3670 54 68
51803 QTP 2x26/32/42CF/UNV PM 32W DT/E 2400 2 0.96 4600 69 67
51773 QTP 2x26/32/42CF/UNV TM 120-277 0.90/0.40 42W DT/E 3200 2 0.95 6080 94 65
Also operates one 57W or 70W 0.53/0.23 57W DT/E 4300 1 1.00 4300 62 69
CFL lamps 0.57/0.25 70W DT/E 5200 1 0.92 4780 71 67
50705 QTP 1x32T8/UNV DIM-TC 120-277 0.27/0.12 FO32XP 3000 1 0.88 2640 30 88
0.05 150 8
50707 QTP 2x32T8/UNV DIM-TC 120-277 0.54/0.24 FO32XP 3000 2 0.88 5280 60/58 88/91
0.05 300 15
50714 QTP 3x32T8/UNV DIM-TCL 120-277 0.73/0.30 FO32XP 3000 3 0.88 7920 87/84 91/94
0.05 450 20
50716 QTP 4x32T8/UNV DIM-TCL 120-277 0.96/0.40 FO32XP 3000 4 0.88 10560 114/110 92/96
0.05 600 27
POWERSENSE
™
QTP models above also operate these lamps: FO25, FO17 & FBO32. POWERSENSE T8 replaces former Helios T8 dimming products.
50718 = QTP 4x32T8/277 DIM PLUS-TCL 277 0.53 FO32XP 3000 4 1.20 14400 145 99
0.05 600 28
50726
= QTP 2x28T5/UNV DIM-TCL 120-277 0.53/0.23 FP28 2900 2 1.00 5800 63/62 92/94
0.01 58 10
POWERSENSE
™
QTP model above also operate these lamps: FP35, FP21 & FP14
49671 QT1x54/120PHO-DIM 120 0.54 FP54T5HO 5000 1 1.00 5000 62 81
0.01 50 8
49672 QT1x54/277PHO-DIM 277 0.23 FP54T5HO 5000 1 1.00 5000 61 82
0.01 50 8
49673 QT2x54/120PHO-DIM 120 1.07 FP54T5HO 5000 2 1.00 10000 120 83
0.01 100 18
49674 QT2x54/277PHO-DIM 277 0.45 FP54T5HO 5000 2 1.00 10000 117 85
0.01 100 18
HELIOS QT models above also operate these lamps: FT55DL & FPC55
Input Input Rated Ballast Input System
Item OSRAM SYLVANIA Voltage Current Lamp Lumens No. of Factor System Wattage Efficacy
Number Description (VAC) (AMPS) Type (lm) Lamps (BF) Lumens (W) (lm/W)
QUICKTRONIC
®
PROFESSIONAL PROStart
®
COMPACT FLUORESCENT - UNIVERSAL VOLTAGE DUAL ENTRY
5,6
NORMAL BALLAST FACTOR
QUICKTRONIC HIGH EFFICIENCY POWERSENSE
®
32 T8 DIMMING SYSTEMS -
A list of controllers is available from OSRAM SYLVANIA
Power-line control (2-wire) or 0-10Vdc control (4-wire) - 100-5% Dimming Range - <10% THD
QUICKTRONIC HIGH EFFICIENCY HELIOS
™
32 T8 DIMMING SYSTEMS -
A list of controllers is available from OSRAM SYLVANIA
High Ballast Factor - “PLUS” High Light Output System -
For 277V, 0-10Vdc Control Applications Only
QUICKTRONIC HIGH EFFICIENCY POWERSENSE 28 T5 DIMMING SYSTEMS -
A list of controllers is available from OSRAM SYLVANIA
Power-line control (2-wire) or 0-10Vdc control (4-wire) - 100-1% Dimming Range - <10% THD
QUICKTRONIC PROFESSIONAL HELIOS 54 T5 HO DIMMING SYSTEMS
3
-
A list of controllers is available from OSRAM SYLVANIA
(0-10Vdc control) - 100-1% Dimming Range - <10% THD
3: Rated lamp lumens and performance data based on PENTRON
®
HO lamps. Rated lumens at 35°C lamp ambient temperature,
5: Rated lamp lumens and performance data based on DULUX T/E series 4 pin lamps. 6: Data is for all models within the brackets.
The maximum input current is shown for maximum input power. ❂ New Product. Contact OSRAM SYLVANIA for product availability.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
182
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
Electronic Fluorescent Ballasts
PLG_graycale_2008_FINAL.qxd:Empty 12/18/07 10:43 AM Page 182