OT EASY 60 II LED control unit Operating instructions
Contents Safety............................................................................................... 4 General instructions Safety instructions Intended use 4 4 4 Description....................................................................................... 5 Function and application Function Important definitions Scene, lighting scene Sequence Fade time Cycle time Operating modes Behaviour after a power failure Connections 5 5 5 5 5 5 5 6 6 6 Installation..................................
OT EASY 60 Safety Safety General instructions The control unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. Safety instructions WARNING! Exposed, live cables. Danger of electric shock! • Only work on the control unit when it is de-energised.
OT EASY 60 Description Description Function and application The OT EASY 60 II LED control unit can be used to implement static and dynamic lighting concepts. Function The OT EASY 60 II LED control unit enables the manual and automatic control of up to four LED luminaire groups on separate channels. Up to 4 x 16 lighting scenes can be programmed, called up individually or run through cyclically in up to 4 sequences (e.g. to simulate daylight).
OT EASY 60 Description Operating modes OT EASY 60 II has three operating modes: • • • Lighting control mode: Brightness is adjusted manually, and luminaire groups and lighting scenes are switched on and off manually. Sequencer mode: The stored lighting scenes are called up automatically one after the other. The fade time between the lighting scenes is adjustable. Daylight simulation: The lighting scenes are called up automatically to simulate light conditions as they change during the course of a day.
OT EASY 60 Installation Installation Connecting the control unit Wiring diagram PE N L Power switch and / or timer switch (optional) L N External switch OT EASY 60 Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) + R G B LINEARlight Colormix LED module Infrared receiver (optional) Y-connector 4 Y-connector Pushbutton coupler (optional) USB adapter Y-Cconnector Max.
OT EASY 60 Installation Connecting the inputs Proceed as follows: Step Task 1 Connect the 4p4c modular connector of the EASY signal line. 2 Strip the power cable, remove the insulation from the phase and neutral wires and connect to the screw terminals. 3 Connect the line of the external pushbutton to the screw terminals, if applicable. 4 Mount the cable strain relief: Use a rubber adapter and cable clamp that are suitable for the power cable diameter; see figure.
OT EASY 60 Installation OT EASY 60 output connections OT EASY 60 output side 16 mm 24 V (+) CH1 (R-) CH2 (G-) 6 mm CH3 (B-) 16 mm 3-wire cable (without PE) CH4 (W-) GND (-) 6 mm Connecting the outputs Connection lines between the control unit and LED modules: • • • Two 3-wire lines (without PE) with the same external diameter Max. length: 10 m Recommended line diameter: 1.5 mm² (line length < 5 m) or 2.
OT EASY 60 Installation Expanding the system Master-slave circuit In a master-slave circuit, up to 16 DALI EASY or OT EASY control units can be controlled simultaneously via a single remote control, up to two pushbutton couplers or a single PC. Note: Configuration of the master-slave circuit via a PC: see the operating instructions of the EASY Color Control Software. Procedure Proceed as follows to set up a master-slave circuit: Step Task 1 Disconnect all control units from the mains supply.
OT EASY 60 Installation Wiring diagram (example of a master-slave circuit) CAUTION! Destruction of the control unit and other devices! • • Master-slave connection lines conduct protective extra-low voltage signals; do not route together with power supply or LED lines. Ensure that the master-slave connection lines are sufficiently insulated against the power supply or lamp lines.
OT EASY 60 Operation Operation Remote control Note: These instructions primarily describe the operation via the DALI EASY RMC remote control. To operate via an EASY PB Coupler, see the separate instructions for the EASY PB Coupler.
max OT EASY 60 Operation Activating the operating modes The lighting control mode is always active. The sequencer mode and daylight simulation are activated via the DIP switches in the battery compartment of the remote control. Activated operating modes DIP switch setting Lighting control mode only DIP switch 3 = OFF DIP switch 4 = OFF ON Sequencer mode (incl. lighting control mode) DIP switch 3 = OFF DIP switch 4 = ON ON Daylight simulation (incl.
OT EASY 60 Operation Storing and calling up a lighting scene „Scene 1“ to „Scene 4“ buttons. Proceed as follows to store lighting scenes: Step A Task 1 Set the brightness of the luminaire group; see "Changing the brightness manually". 2 Press the desired button for at least 3 seconds. 3 Confirmation: luminaires flash. To call up a lighting scene: Via short press. ...
OT EASY 60 Operation Setting the fade and cycle time Set the fade time for the sequencer mode and the cycle time for the daylight simulation. To increase the time: „Start/Time+“ button To decrease the time: „Stop/Time−“ button Proceed as follows: Step Task 1 Press the button for at least 3 seconds. The time is shown on the display; see below.
OT EASY 60 Operation Example of a daylight simulation Brightness Cycle time 12h. Clock-controlled switch-on at 8 a.m. Scene 3 Scene 2 90% 80% Scene 4 Scene 1 50% Cycle time 8:00 12:00 16:00 20:00 Time Troubleshooting If you cannot remedy the fault, please contact the Customer Service department of the luminaire manufacturer. Fault Cause Remedy Luminaire does not function No mains voltage present. Check the mains supply fuses. Illuminant defective. Replace illuminant.
OT EASY 60 Appendix Appendix Technical data For LED modules With respect to the output conditions: 1 x LINEARlight Colormix Flex (4m), 7 x LINEARlight Colormix, etc. Operating voltage 220-240 VAC / 50-60 Hz Permissible voltage fluctuations 198-264 VAC Line current, nominal 0.33 A @ 230 V Output voltage 24 VDC Max. module wattage 60 W, distributed over all outputs (60 W on only one output is also possible) Power factor PF > 0.95 Max.
OT EASY 60 Appendix Applicable standards Safety UIEC 61347 Performance IEC 62384 Radio interference EN 55015, EN 55022 Harmonic content IEC 61000-3-2 Immunity IEC 61547 Dimensions Conformity with the relevant EU directives is confirmed by the CE symbol.
IV 2009 OT_EASY_60_II_ma0904en_we1.01.indd OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg Germany Tel : +49 (0) 1803 677 - 200 (kostenpflichtig / charges apply) Fax.: +49 (0) 1803 677 - 202 www.osram.com www.osram.