Cota WPT System User Manual Light Ring Status
3.2 ENABLE COTA WPT SOURCE OPERATION
1. Go to System >> Health Monitoring, click the System Status tab, and verify that all the components under the
Components Status are green.
2. The Cota WPT clients are factory registered with your Cota WPT source and will appear on the Cota Web Admin
page.
3. Click Start Charging for the desired Cota WPT client.
4. When shutting down the Cota WPT source, use the Shut Down command in the Cota Web Admin first, and then
wait for 30 seconds before disconnecting the Cota WPT source from AC power.
4LIGHT RING STATUS
State Light Ring Color Pattern Description
Idle/Debug Slowly flashing orange The system is in idle or debug state.
Calibration Purple segments
progressing
The system is performing system calibration and initialization. The
system enters this state automatically upon coming up.
Wait for Clients Light red background color
with one bright light
segment moving slowly in
circle
This state indicates the system has been initialized and calibrated, but it
does not detect any Cota WPT client/device the vicinity.
Ready Green background color
with one pink light
segment moving in circle
The system detected at least one Cota WPT client and is ready to deliver
power to that Cota WPT client, however, the Cota WPT clients/devices
might have not been authorized or enabled to charge.
Powering Multiple light patterns
moving quickly in circle
The system is delivering power to Cota WPT client (s) or charging the
Cota WPT client (s).
Identifying Solid green color ring
flashing every second
Users can use the web interface to locate the Cota WPT source. Once
users click on Identify Transmitter button, light ring will flash for at least
15 seconds (configurable duration).
Error/Over Temp Solid red color ring flashing
every second
The system has encountered an error condition that it cannot continue
without intervention. All critical errors will force the system to enter this
state. Users will need to check the system log and system temperature to
get more detail on the error.