User's Manual

31
(out) client unit since last retrieval.
A user may modify any fields with modifiable property marked “yes” in the table. To change any of the modifiable
fields, double click the value of the field; the user is prompted to enter a valid value for the field. Once the
correct value is entered, user may click the Submit button. User may abort the modification by click the Cancel
button.
In the server (Figure 6) or client (Figure 8) table, only the following fields can be modified by double
clicking the individual one:
Channel Number
Security Code
When double clicking the Channel Number field, the user is prompted to input a new channel number
(range from 1 to 12). By clicking the submit button, the AirEZY unit will be instructed to use the new
channel number after next AirEZY reboot.
When double clicking the Security Code field, the user is prompted to input a new security code. By click
the submit button, the AirEZY unit starts to use the new security code after next AirEZY reboot.
The following rules must be observed when modifying the channel number and/or the security code for
clients and associated server:
1) Modifications to clients and its server must be identical.
2) Clients must be rebooted prior to rebooting the server.
If the above rules are not followed, the AirEZY link between server and clients will be lost.