User's Manual

Table Of Contents
CHAPTER 3
Using terminal commands
27
0 – 16 Kbytes (e.g. model 25128)
1 – 32 Kbytes (e.g. model 25256)
RETURNS Nothing.
REMARKS SET only.
REMOTE Yes, SET only.
EXAMPLE FDEV 1
15535 FDEV 0
#
INFO
DESCRIPTION Returns various status information.
PARAMETER None.
RETURNS A list of a devices internal variables:
ID INFO rf_in rf_out date time ver clk stack cop batt temp
days_uptime hr:min_uptime rssi pmp_low pmp_high type slot
samples po err_level
#
The formats for the above parameters are as follows:
rf_in and rf_out as a decimal
date as dd/mm/yyyy
time as hh:mm:ss
ver as x.x
clk, stack, and cop as decimal; they represent internal
housekeeping parameters: the A724 uses cop to number
watchdog occurrences, but clk and stack are currently
undefined
batt as battery level using the standard voltage conversion
equation (0 is 0 volts, 255 is 20 volts)
temp as internal temperature in the A724 housing, which is
device dependent. The precision of the sensing element is
low (±2°C), but it is sufficient for battery power management