FREQ
15535 FREQ 433925000 25000 0
#
RSSI
DESCRIPTION Sets/returns the Relative Signal Strength Indicator threshold at
which the RF receiver must wake up.
PARAMETERS The threshold value. For the A725, it can take values from 0 to
255; it is typically factory set to 42.
RETURNS The instant RSSI value and the programmed threshold.
REMARKS GET/SET.
REMOTE No.
EXAMPLE RSSI 50
15535 RSSI 0
#
RSSI
15535 RSSI 34 50 0
#
Note: The values of the RSSI threshold have no units, they are arbi-
trary. However, a value of 160 corresponds approximately to
the maximum value allowed in the addVANTAGE software
(that is, 8 µV).
ID
DESCRIPTION Sets/returns the node’s ID.
PARAMETERS The node ID.
RETURNS The node ID.
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE ID 4557
15535 ID 0
#