User's Manual

Table Of Contents
CHAPTER 3
Using terminal commands
25
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE PMP 65 72
15535 PMP 0
#
PMP
15535 PMP 65 72 0
#
DATA
DESCRIPTION Returns data stored for a certain device.
Note: This command cannot be used to retrieve data from the
SDI-12 subsystem. Please see the description of the SDI-
DATA command therefore.
PARAMETER The ID of the device for which the data is requested and the date/
time (in the standard format) the data was stored. If missing, then it
refers to the data of the local device.
RETURNS A data block.
Note: The addSDI does not support analog sensors.
REMARKS GET only. If the date/time parameter is not included, the latest
data is returned. If the date/time parameter is included, the data
closest to, but later than, the given date/time is returned.
REMOTE Yes, for a GET, but only one frame at a time. The A725 can issue
the command only for itself, locally.
EXAMPLE DATA 15535 1/3/2000 12:12:12
15535 DATA b1 b2 b3 ... bn 0
#
The data block returned will typically contain a number of data
frames (telegrams). The structure of a block is as follows:
dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy ... dn cs
where:
dd mm yyyy is the date
hh mm ss is the time