User's Manual

Table Of Contents
CHAPTER 3
Performing Advanced Functions
30
EXAMPLE INFO
15535 INFO 0 84 13/12/2006 20:02:29 2.10 2 0 0 85
59 0 3:52 42 65 72 12 60 1 0
#
RX
DESCRIPTION Switches the unit to permanent receive mode (for tuning pur-
poses).
PARAMETERS None.
RETURNS Nothing.
REMARKS The system stops, and exits the command only when a key is
pressed. This command returns no message.
REMOTE No.
EXAMPLE RX
15535 RX 0
#
TX
DESCRIPTION Switches the unit to transmit mode (for tuning purposes).
PARAMETERS None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated
carrier), 0 (sends a 2 kHz modulated carrier) or 5 (sends a mixed 1
+ 2 kHz modulated carrier).
RETURNS Nothing.
REMARKS The system stops, and exits the command only when a key is
pressed. This command returns no message.
REMOTE No.
EXAMPLE TX
15535 TX 0
#
TX 1
15535 TX 0
#