User's Manual

Performing Advanced Functions
pmp_low and pmp_high are the programmed values with the PMP
command (irrelevant for the A733GSM)
type is used to represent the device type; following types are assigned
currently:
0 for A730MD
1 for A720
2 for A730SD
3 for A720B
4 for A733
5 for A723
6 for A440
7 for A733 GSM
8 for A731
9 for A732
slot and samples are the actual values programmed by means of the
SLOT command
po is the power output of the device during the last frame sent; this value is
relative (50 mW corresponds to a value of approx. 25 while 500 mW
corresponds to a value of approx. 200) (irrelevant for the A733GSM)
err_level is the error value; 0 means no error
R
EMARKS GET only.
REMOTE Yes, GET only. The A733 can issue the command both remotely and locally.
E
XAMPLE INFO
9193 INFO 255 0 18/4/1999 21:5:11 1.3 0 0 0 91 72 40 1:46 58
65 72 3 900 15 175 0
#
PORT
AVAILABLE FOR
A731 A733A732 A733GSM
DESCRIPTION A complex command acting upon the I/O ports of a device.
P
ARAMETERS A control byte specifying the command, the bit of the port the command is acting
on, and two 16-bit parameters, depending on the control byte; for some
commands, one or both of them may be missing. However, if they are needed for a
certain command but not given, null values are implied.
The control byte’s significance is shown in Fig. 17.
Command Code
Port Number
Fig. 17: The Control Byte Layout
The Port Number selects a the port that will be affected by the command.
For the A733, only 0000 to 0011 are accepted (only four ports are
available).
33