User's Manual
Using terminal commands
REMOTE Yes, SET only.
E
XAMPLE PMP 65 72
9193 PMP 0
#
PMP
9193 PMP 65 72 0
#
ANLG
AVAILABLE FOR
A731 A733A732 A733GSM
DESCRIPTION Sets/returns various parameters of the analog subsystem (for example, the
sampling/averaging method used for individual data acquisition channels).
P
ARAMETERS A control byte specifying the command and the analog input channel number the
command is acting on:
Command Code
Channel Number
Fig. 14: The ANLG Control Byte Layout.
Some commands may also require one or two additional 12-bit parameters
representing threshold values.
• The Channel Number selects the analog channel that will be affected by
the command. For the A733, only 0000 to 1011 are accepted (only 12
analog channels are available).
• The Command Code specifies the operation that will be applied to the
selected channel. They are described in Table below.
Code Description Parameters Returns
0000 RSM – Read Sampling Method.
This command reads the current
programmed sampling method
for all analog input channels.
None The current
sampling methods
and the result (OK
or ERROR); see
also the sampling
table below
0001 SSMMI – Set Sampling Method
to Minimum. The specified
analog channel is instructed to
store the lowest sampled value.
The channel num-
ber
Result (OK or
ERROR)
0010 SSMMA – Set Sampling Method
to Maximum. The specified
analog channel is instructed to
store the highest sampled value.
The channel num-
ber
Result (OK or
ERROR)
0011 SSMS – Set Sampling Method to
Sum. The specified analog
channel is instructed to store the
sum of all sampled values.
The channel num-
ber
Result (OK or
ERROR)
0100 SSMAA – Set Sampling Method
to Arithmetic Average. The
s
p
ecified analo
g
channel is
The channel num-
ber
Result (OK or
ERROR)