User's Manual

CHAPTER3
UsingTerminalCommands
24
REMARKS GET/SET.
Time ranges may overlap or wrap around midnight (for example,
23:30 to 00:30). To delete an LT range entry, the from_time and the
to_time must be set to the same value (for example, 00:00 to 00:00).
The following power save modes exist:
no LT setting: the radio/GSM module is always turned off. This
mode is equivalent to turning on the GSM power saving on an
A733 Series 3.
the listen times congured for 00:00..24.00: the radio/GSM
module is always turned on. This mode is equivalent to turning off
the GSM power saving on an A733 Series 4.
the listen times congured for some time ranges. The radio/GSM
module is turned on during that times, and off otherwise.
Note: for outbound connections/commands (getting the initial RTC setting
after powering up, delivering notications, connecting to the gateway
over GPRS, remote commands to a different device), the radio/GSM
module is turned on independent of the LT settings and stays on until
the time specied by LTNOTIFYTIMEOUT is over!
RETURNS The current settings
REMOTE Yes.
EXAMPLE # lt 15:00 18:00 0
5 lt 0
#
# lt 08:00 10:00 1
5 lt 0
#
# lt
5 lt
15:00 18:00 0
08:00 10:00 1
0
#
LTNOTIFYTMOUT
DESCRIPTION This command is used to congure how long the RTU disables power
saving after a notication is sent.
PARAMETERS The new timeout setting in seconds (0..65535).
REMARKS GET/SET.