User's Manual

CHAPTER3
UsingTerminalCommands
26
ID
DESCRIPTION Sets/returns the node’s ID.
PARAMETERS The node ID.
REMARKS GET/SET.
RETURNS The node ID.
REMOTE Yes, SET only.
EXAMPLE # ID 445
42914 ID 0
#
# ID
445 ID 445 0
#
INFO
DESCRIPTION Returns various status information.
PARAMETERS None.
REMARKS GET only.
RETURNS A list of a device’s internal variables:
ID INFO rf_in rf_out date time ver clk stack cop batt temp
days_uptime hr:min_uptime rssi pmp_low pmp_high type slot
samples po err_level
#
The formats for the above parameters are as follows:
rf_in and rf_out as a decimal.
date as dd/mm/yyyy.
time as hh:mm:ss.
ver as x.x.
clk, stack, and cop as decimal. They represent internal
housekeeping parameters: the A753 uses cop to number
watchdog occurrences, but clk and stack are currently undefined.
batt as battery level, using the standard voltage conversion
equation (0 is 0 volts, 255 is 20 volts).
temp as internal temperature in the housing, which is device
dependent. The precision of the sensing element is low (±2°C),
but it is sufficient for battery power management (charge/