User's Manual
Table Of Contents
CHAPTER3
UsingTerminalCommands
31
REMARKS GET/SET.
RETURNS The current settings.
REMOTE Yes.
EXAMPLE # anlgthreshold 80 2
5 anlgthreshold 0
#
# anlgthreshold
5 anlgthreshold 0 0 80 0 0 0 0 0 0 0 0 0 0
#
CNTRTHRESHOLD
DESCRIPTION The RTU does not store data for counter channels when the number of
pulses is less than the given cut-off threshold, and thus save radio/
GSM traffic).
PARAMETERS A threshold, specified as number of pulses on the CNTR input pin
(0..65535) and a CNTR channel. The CNTR channel (0 = IOA, 1 = IOB,
2 = IOC, 3 = IOD) or omitted (to set the threshold for all counter
inputs)
REMARKS GET/SET.
RETURNS The current settings
REMOTE Yes.
EXAMPLE # cntrthreshold
5 cntrthreshold 0 1 0 0 0
#
# cntrthreshold 80 1
5 cntrthreshold 0
#
DYNSLOT
DESCRIPTION The dynamic slot switching function checks whether the measurement
value of the given sensor matches the given condition, then switches
between two operating modes:
• normal mode (when the condition is false and the lock timer
is zero)
• exception mode (when the condition is true and the lock
timer is nonzero)
The rules for the mode switching are: