User's Manual

CHAPTER3
UsingTerminalCommands
31
REMARKS GET/SET.
RETURNS The current settings.
REMOTE Yes.
EXAMPLE # anlgthreshold 80 2
5 anlgthreshold 0
#
# anlgthreshold
5 anlgthreshold 0 0 80 0 0 0 0 0 0 0 0 0 0
#
CNTRTHRESHOLD
DESCRIPTION The RTU does not store data for counter channels when the number of
pulses is less than the given cut-off threshold, and thus save radio/
GSM trafc).
PARAMETERS A threshold, specied as number of pulses on the CNTR input pin
(0..65535) and a CNTR channel. The CNTR channel (0 = IOA, 1 = IOB,
2 = IOC, 3 = IOD) or omitted (to set the threshold for all counter
inputs)
REMARKS GET/SET.
RETURNS The current settings
REMOTE Yes.
EXAMPLE # cntrthreshold
5 cntrthreshold 0 1 0 0 0
#
# cntrthreshold 80 1
5 cntrthreshold 0
#
DYNSLOT
DESCRIPTION The dynamic slot switching function checks whether the measurement
value of the given sensor matches the given condition, then switches
between two operating modes:
normal mode (when the condition is false and the lock timer
is zero)
exception mode (when the condition is true and the lock
timer is nonzero)
The rules for the mode switching are: