• when the condition becomes true the first time, exception
mode is entered and the lock timer is set
• while the condition is true, the lock timer is set at every
sample, thus does not reach zero
• while the condition is false, the lock timer is decremented if
not already zero
• when the lock timer reaches zero, normal mode is entered
• the SLOT settings are only changed when the mode changes
Thus, the RTU enters exception mode whenever a sample value
matches the condition, and stays there until the sample value does
notmatch the condition for at least the given locktime (this prevents
excessive wear of the EEPROM due to jitter in the measurement
value).
PARAMETERS
REMARKS GET/SET.
RETURNS
REMOTE Yes.
EXAMPLE we set up theDYNSLOT feature to measure IOA and IOB every
minute when the sensor value on cabling 1 is more than 1.25
Volts (ADC value 32768):
ReturnedErrorsList
Following are error messages you might get.
CommandLineInterpreter
• 1 — nonexistent command
• 2 — command line buffer overflow (input line too long)
• 3 — internal error
• 4 — reserved
• 5 — missing or false parameters in command
• 6 — operation not implemented
• 7 — remote operation not allowed
• 8 — invalid IMEI Number
• 9 — command not supported in this configuration
DeviceDescriptorandStorageHandler
• 10 — device not found (attempt to perform a command on a
nonexistent device)
• 11 — device already exists
• 12 — reserved
• 13 — no more space for descriptors (too many devices)