User's Manual

CHAPTER3
UsingTerminalCommands
28
7.2 volts) for switch off, for a standard 6.2 volt NiMH battery. From
these values, other thresholds are internally computed.
REMARKS GET/SET.
RETURNS The lower (switch on) and the higher limit (switch odd), both in volts x
10.
REMOTE Yes, SET only.
EXAMPLE # PMP 65 72
42914 PMP 0
#
# PMP
42914 PMP 65 72 0
#
TIME
DESCRIPTION Sets/returns the real time clock.
PARAMETERS The actual time, or none in the GET version.
REMARKS GET/SET.
RETURNS The actual time as dd/mm/yyyy hh:mm:ss.
REMOTE Yes.
EXAMPLE # TIME 20/06/2009 12:10:10
42914 TIME 0
#
# TIME
42914 TIME 20/06/2009 12:10:10 0
#
TYPE
DESCRIPTION Requests the hardware type information of the device.
PARAMETERS None.
REMARKS GET only.
RETURNS The hardware type.
REMOTE Yes.
EXAMPLE # TYPE
42914 TYPE A753 0
#