User's Manual

CHAPTER3
CommunicatingwiththeRTU
22
CommunicatingwiththeRTU
You can use a Windows Hyperterminal window to connect to the A753
remote wireless modem. After you have installed the system, follow
these steps to configure the device and set the default parameters:
Note: To configure the A753, you must have a special adapter cable (item
number 200.720.540 from your Adcon distributor) and plug it into the
SOLAR CELL connector.
1. Open a Hyperterminal window.
2. Select the appropriate serial port and click OK.
3. Configure your terminal as follows:
19200 baud
•1 stop bit
8 data bits
•No parity
No protocol (neither hardware nor software)
4. Select OK to open the terminal window.
5. Press Enter to generate a response in the window.
Note: The A753 has two command line modes, bootloader and firmware.
BootingtheA753
Note: This section is included for informational purposes. You will rarely
need to boot the A753. However, when you do need to do so, you will
work within a Windows Hyperterminal window on your computer.
BootloaderMode
When the A753 starts from a power-up reset (such as when you
connect the battery to the unit), it enters the bootloader mode. If you
press no keys in the interim, the A753 enters the firmware mode in
five seconds.
If you want to work with commands in the bootloader rather than
continuing to the firmware mode, press ESC within five seconds after
seeing the following sign-on message:
A753 Bootloader V1.7
Copyright (C) Adcon Telemetry GmbH 2009
Press <ESC> within 5 seconds to start the commandline
interface...
You are in the command line interface of the bootloader. This interface
enables you to perform certain commands such as upgrading to a new
firmware or rebooting the device.
Note: If you press no keys within 60 seconds, the bootloader command line
interface will start firmware mode automatically.